Optical methods for power measurement of terahertz radiation

被引:35
作者
Steiger, Andreas [1 ]
Gutschwager, Berndt [1 ]
Kehrt, Mathias [1 ]
Monte, Christian [1 ]
Mueller, Ralf [1 ]
Hollandt, Joerg [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
SPECTRAL RESPONSIVITY; RADIOMETRY; LASER;
D O I
10.1364/OE.18.021804
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Precision power measurements of terahertz (THz) radiation are required to establish metrological applications in the THz spectral range. However, traceability to the International System of Units (SI) has been missing in the THz region in the past. The Physikalisch-Technische Bundesanstalt (PTB), as the national metrology institute of Germany, determines the spectral responsivity of detectors for THz radiation by using two complementary optical methods: source- and detector-based radiometry. Both approaches have been successfully prototyped, and a pyroelectric THz detector with a well-defined aperture is used to verify the consistency of the two independent calibration methods. These primary investigations led to the design of a new measurement facility for the determination of THz radiant power and the responsivity calibration of THz detectors traceable to the SI. (C) 2010 Optical Society of America
引用
收藏
页码:21804 / 21814
页数:11
相关论文
共 10 条
[1]  
[Anonymous], 1002008 JCGM
[2]  
[Anonymous], EXPT METHODS PHYS SC
[3]   Diffraction effects in the radiometry of coherent beams [J].
Butler, DJ ;
Kohler, R ;
Forbes, GW .
APPLIED OPTICS, 1996, 35 (13) :2162-2166
[4]   Calculable blackbody radiation as a source for the determination of the spectral responsivity of THz detectors [J].
Gutschwager, B. ;
Monte, C. ;
Delsim-Hashemi, H. ;
Grimm, O. ;
Hollandt, J. .
METROLOGIA, 2009, 46 (04) :S165-S169
[5]   Terahertz quantum cascade laser as local oscillator in a heterodyne receiver [J].
Hübers, HW ;
Pavlov, SG ;
Semenov, AD ;
Köhler, R ;
Mahler, L ;
Tredicucci, A ;
Beere, HE ;
Ritchie, DA ;
Linfield, EH .
OPTICS EXPRESS, 2005, 13 (15) :5890-5896
[6]   THz metrology [J].
Kleine-Ostmann, T. ;
Schrader, T. ;
Bieler, M. ;
Siegner, U. ;
Monte, C. ;
Gutschwager, B. ;
Hollandt, J. ;
Steiger, A. ;
Werner, L. ;
Mueller, R. ;
Ulm, G. ;
Pupeza, I. ;
Koch, M. .
FREQUENZ, 2008, 62 (5-6) :135-146
[7]   New UV spectral responsivity scale of the PTB based on a cryogenic radiometer and an argon plasma arc radiation source [J].
Meindl, P. ;
Klinkmueller, A. E. ;
Werner, L. ;
Johannsen, U. ;
Gruetzmacher, K. .
METROLOGIA, 2006, 43 (02) :S72-S77
[8]   Improved comparison of the World Radiometric Reference and the SI radiometric scale [J].
Romero, J ;
Fox, NP ;
Frohlich, C .
METROLOGIA, 1996, 32 (06) :523-524
[9]   Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer [J].
Werner, L ;
Fischer, J ;
Johannsen, U ;
Hartmann, J .
METROLOGIA, 2000, 37 (04) :279-284
[10]   Towards traceable radiometry in the terahertz region [J].
Werner, L. ;
Huebers, H.-W. ;
Meindl, P. ;
Mueller, R. ;
Richter, H. ;
Steiger, A. .
METROLOGIA, 2009, 46 (04) :S160-S164