Thermal evaluation and modeling of a double-pass solar collector for air heating

被引:16
作者
Mariana Gonzalez, Silvina [1 ]
Flores Larsen, Silvana [1 ]
Hernandez, Alejandro [1 ]
Lesino, Graciela [1 ]
机构
[1] Univ Nacl Salta, CONICET, INENCO, Salta, Argentina
来源
2013 ISES SOLAR WORLD CONGRESS | 2014年 / 57卷
关键词
solar air collector; double pass collector; air heating; PERFORMANCE; HEATER;
D O I
10.1016/j.egypro.2014.10.235
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper shows the experimental study of the thermal efficiency of a counter-flow double-pass solar air heater and the theoretical thermal model developed to describe its thermal behavior. The prototype was designed and manufactured at INENCO, Universidad Nacional de Salta, Argentina, The useful collection area is 2m(2), and a channel height of 0.025m. The edge and bottom surfaces are thermally insulated with a 0.05 m thick glass wool layer. The air flow is forced by a tangential fan installed in a 0.18m diameter pipe that is connected to the flow outlet. The collector was mounted with a slope of 40 degrees facing north, in order to maximize the intensity of solar irradiance during winter. Experimental outdoor tests were carried out during a winter period, with maximum solar irradiance on the collector plane around 1050 W/m(2). A semi-empirical thermal model was developed in order to simulate the air temperature at the collector outlet under different outdoor climatic conditions and air flow. Experimental results and the predictions of the theoretical model were found to be in good agreement. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:2275 / 2284
页数:10
相关论文
共 21 条
[1]  
Alia D., 2012, JOURAL FREE SOFTWARE
[2]   A mathematical model of thermal performance of a solar air heater with slats [J].
Ammari, HD .
RENEWABLE ENERGY, 2003, 28 (10) :1597-1615
[3]   A review of the performance of double pass solar air heater [J].
Chamoli, Sunil ;
Chauhan, Ranchan ;
Thakur, N. S. ;
Saini, J. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01) :481-492
[4]   Solar drying of sweet pepper and garlic using the tunnel greenhouse drier [J].
Condorí, M ;
Echazú, R ;
Saravia, L .
RENEWABLE ENERGY, 2001, 22 (04) :447-460
[5]   Analytical model for the performance of the tunnel-type greenhouse drier [J].
Condorí, M ;
Saravia, L .
RENEWABLE ENERGY, 2003, 28 (03) :467-485
[6]  
Condori M, 2004, 8 WORLD REN EN C AUG
[7]  
Duffle JA., 2006, Solar engineering of thermal processes, V3rd
[8]   Flow distribution in unglazed transpired plate solar air heaters of large area [J].
Gunnewiek, LH ;
Brundrett, E ;
Hollands, KGT .
SOLAR ENERGY, 1996, 58 (4-6) :227-237
[9]  
Hernandez A, 2007, AVANCES ENERGIAS REN, V11, P75
[10]  
Hernandez A, 2008, AVANCES ENERGIAS REN, V12, p133