Non-Invasive Neutral Atom Density Measurements using fs-TALIF in a Magnetic Linear Plasma Device

被引:0
|
作者
Dogariu, Arthur [1 ]
Evans, Eugene [2 ]
Vinoth, Sangeeta P. [2 ]
Cohen, Samuel A. [2 ]
机构
[1] Princeton Univ, Mech & Aerosp Engn Dept, Princeton, NJ 08544 USA
[2] Princeton Plasma Phys Lab, Princeton, NJ 08540 USA
来源
2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) | 2021年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on femtosecond TALIF measurements of neutral density in a mirror plasma device. We have measured H density down to 10(11) cm(-3), and the dynamics of the H neutrals in quasi-CW and pulsed plasma. (c) 2021 The Author(s)
引用
收藏
页数:2
相关论文
共 13 条
  • [1] Use of electrical measurements for non-invasive estimation of plasma electron density in the inductively coupled SPIDER ion source
    Jain, Palak
    Recchia, Mauro
    Sartori, Emanuele
    Serianni, Gianluigi
    Poggi, Carlo
    Ugoletti, Margherita
    Zaniol, Barbara
    PLASMA PHYSICS AND CONTROLLED FUSION, 2023, 65 (09)
  • [2] Non-invasive measurements of the electron density in technical plasmas using 26,5 GHz microwave interferometry
    Selenin, V.
    Schwabedissen, A.
    Bunse, D.
    VAKUUM IN FORSCHUNG UND PRAXIS, 2007, 19 (06) : 6 - 9
  • [3] Influence of the oscillometric calibration method on accuracy and precision of continuous non-invasive arterial pressure measurements using the CNAP™ device
    JY Wagner
    I Negulescu
    M Schofthaler
    A Hapfelmaier
    AS Meidert
    W Huber
    RM Schmid
    B Saugel
    Critical Care, 18 (Suppl 1):
  • [4] Eddy current density for non-invasive treatment system for urinary incontinence using functional continuous magnetic stimulator (FCMS)
    Ishikawa, N
    Suda, S
    Sasaki, T
    Hosaka, H
    Yamanishi, T
    Yasuda, K
    Ito, H
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON BIOELECTROMAGNETISM, 1998, : 123 - 124
  • [5] Method to estimate the electron temperature and neutral density in a plasma from spectroscopic measurements using argon atom and ion collisional-radiative models
    Sciamma, Ella M.
    Bengtson, Roger D.
    Rowan, W. L.
    Keesee, Amy
    Lee, Charles A.
    Berisford, Dan
    Lee, Kevin
    Gentle, K. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [6] Evaluation of non-invasive hemoglobin measurements using the Masimo Rainbow Radical-7 (R) device in a patient with extracorporeal membrane oxygenation
    Moreno, I.
    Artieda, O.
    Vicente, R.
    Zarragoikoetxea, I.
    Vicente, J. L.
    Barbera, M.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2014, 61 (07): : 388 - 391
  • [7] Using electromagnetic reciprocity and magnetic resonance current density imaging to fit multi-electrode montage for non-invasive brain stimulation
    Dutta, Arindam
    Dutta, Anirban
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 447 - 451
  • [8] Neutral atom density measurements of xenon plasma inside a μ10 microwave ion thruster using two-photon laser-induced fluorescence spectroscopy
    Tsukizaki, Ryudo
    Yamashita, Yusuke
    Kinefuchi, Kiyoshi
    Nishiyama, Kazutaka
    VACUUM, 2021, 190
  • [9] Evaluating the Non-Invasive Measurement of Apple Aroma Using Electronic Nose Device through Comparison with Direct Mass Spectrometry, Sugar Content, and Ripeness Measurements
    Fujioka, Kouki
    SENSORS, 2024, 24 (10)
  • [10] Renal blood flow measurements by magnetic resonance imaging using arterial spin labelling as a novel non-invasive biomarker in paediatric renal transplant recipients
    Marks, S.
    Nery, F.
    Cutajar, M.
    Clark, C.
    Thomas, D.
    Gordon, I.
    PEDIATRIC NEPHROLOGY, 2016, 31 (10) : 1941 - 1941