Immobilization of 8-hydroxyquinoline onto silicone tubing for the determination of trace elements in seawater using flow injection ICP-MS

被引:35
作者
Willie, SN [1 ]
Tekgul, H
Sturgeon, RE
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
[2] Istanbul Tech Univ, Dept Chem, TR-80626 Istanbul, Turkey
关键词
flow injection; preconcentration; ICP-MS; trace analysis; immobilized; 8-hydroxyquinoline;
D O I
10.1016/S0039-9140(98)00153-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple on-line method is described for the preconcentration of Mn, Co, Ni, Cu, Zn, Cd and Pb from sea water using 8-hydroxyquinoline immobilized onto silicone tubing (Sil-8-HQ) via the Mannich reaction. Recoveries between 35 and 95% and limits of detection in the ppt range were obtained using a 2 m long Sil-8-HQ tube with a sample flow rate of 1.0 mi min(-1). A tube could be subjected to sample loading and elution cycles over 200 times. The capacity was 1.5 and 1.3 mu g cm(-2) for Cu and Mn, respectively. Cu, Cd, Co, Pb, Mn, Zn and Ni were determined in coastal and open ocean seawater using flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Good agreement with certified values for the certified reference materials NASS-4 and CASS-3 was demonstrated when quantitation was undertaken by the method of additions. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:439 / 445
页数:7
相关论文
共 24 条
[1]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[2]   DESIGN AND EVALUATION OF AN ONLINE MICROCOLUMN PRE-CONCENTRATION TECHNIQUE FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BEINROHR, E ;
CAKRT, M ;
RAPTA, M ;
TARAPCI, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :1005-1007
[3]   SYNTHETIC ASPECTS OF THE CHARACTERIZATION OF SOME SILICA-BOUND COMPLEXING AGENTS [J].
FULCHER, C ;
CROWELL, MA ;
BAYLISS, R ;
HOLLAND, KB ;
JEZOREK, JR .
ANALYTICA CHIMICA ACTA, 1981, 129 (AUG) :29-47
[4]   A comparison of preconcentration reagents for flow injection analysis flame atomic spectrometry [J].
Greenway, GM ;
Nelms, SM ;
Skhosana, I ;
Dolman, SJL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) :1909-1915
[5]   SILICA-GEL AS AN INSOLUBLE CARRIER FOR PREPARATION OF SELECTIVE CHROMATOGRAPHIC ADSORBENTS - PREPARATION OF 8-HYDROXYQUINOLINE SUBSTITUTED SILICA-GEL FOR CHELATION CHROMATOGRAPHY OF SOME TRACE METALS [J].
HILL, JM .
JOURNAL OF CHROMATOGRAPHY, 1973, 76 (02) :455-458
[6]  
*INT ORG STAND, 1993, GUID EXPR UNC MEAS
[7]   METAL-ION CHELATION CHROMATOGRAPHY ON SILICA-IMMOBILIZED 8-HYDROXYQUINOLINE [J].
JEZOREK, JR ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :366-373
[8]   Syntheses of polysulfones containing chelating reagents and their application to the preconcentration of trace metals [J].
Kan, M ;
Guiver, MD ;
Robertson, GP ;
Willie, SN ;
Sturgeon, RE .
REACTIVE & FUNCTIONAL POLYMERS, 1996, 31 (03) :207-218
[9]   SYNTHESIS, PROPERTIES AND APPLICATIONS OF SILICA-IMMOBILIZED 8-QUINOLINOL .1. CHARACTERIZATION OF SILICA-IMMOBILIZED 8-QUINOLINOL SYNTHESIZED VIA A MANNICH REACTION [J].
LAN, CR ;
YANG, MH .
ANALYTICA CHIMICA ACTA, 1994, 287 (1-2) :101-109
[10]   SYNTHESIS, PROPERTIES AND APPLICATIONS OF SILICA-IMMOBILIZED 8-QUINOLINOL .2. ONLINE COLUMN PRECONCENTRATION OF COPPER, NICKEL AND CADMIUM FROM SEA-WATER AND DETERMINATION BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
LAN, CR ;
YANG, MH .
ANALYTICA CHIMICA ACTA, 1994, 287 (1-2) :111-117