Effect of subject size on electromagnetic radiation from source in human body following 2450MHz radio frequency exposure

被引:2
作者
Xu, Lisheng [1 ]
Meng, Max Q. -H. [1 ]
Ren, Hongliang [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
来源
2007 IEEE INTERNATIONAL CONFERENCE ON INTEGRATION TECHNOLOGY, PROCEEDINGS | 2007年
关键词
radiation effect; radiation efficiency; half-wavelength; dipole; FDTD;
D O I
10.1109/ICITECHNOLOGY.2007.4290488
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For assessment of compliance with the safety guidelines, the radiation effects and efficiencies of ingested wireless devices in human body trunk models of five-year-old children, ten-year-old children and adults are studied using several homogenous models and a half-wavelength dipole at the frequency of 2450 MHz in this paper. The finite-difference time-domain (FDTD) method is used for analyzing the radiation effects and efficiencies. Results show that radiation efficiencies decrease with the increment of body size greatly, ranging from -53 dB to -116 dB. Considering the signal efficiency of wireless device and safety guidelines of radiation exposure, we recommend to set the ingested wireless device to different power levels for users with different body size such as five-year-old children, ten-year-old children and adults.
引用
收藏
页码:326 / +
页数:2
相关论文
共 17 条
[1]  
Chan YW, 2005, P ANN INT IEEE EMBS, P7754
[2]  
Charles, 1995, HDB BIOL EFFECTS ELE
[3]   Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz [J].
Chirwa, LC ;
Hammond, PA ;
Roy, S ;
Cumming, DRS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) :484-492
[4]   SPECIFIC ABSORPTION RATE IN RATS EXPOSED TO 2,450-MHZ MICROWAVES UNDER 7 EXPOSURE CONDITIONS [J].
CHOU, CK ;
GUY, AW ;
MCDOUGALL, JA ;
LAI, H .
BIOELECTROMAGNETICS, 1985, 6 (01) :73-88
[5]   Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :2835-2846
[6]   Some present problems and a proposed experimental phantom for SAR compliance testing of cellular telephones at 835 and 1900 MHz [J].
Gandhi, OP ;
Kang, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09) :1501-1518
[7]   Wireless capsule endoscopy [J].
Iddan, G ;
Meron, G ;
Glukhovsky, A ;
Swain, P .
NATURE, 2000, 405 (6785) :417-417
[8]  
IRAZOQUI PP, 2003, 1 INT IEEE EMBS C NE, V1, P622
[9]  
Kawoos U, 2005, NORTHEAST BIOENGIN C, P17
[10]  
Kim J, 2003, 2003 IEEE TOPICAL CONFERENCE ON WIRELESS COMMUNICATION TECHNOLOGY, P202