Determination of isotope ratios of metals (and metalloids) by means of inductively coupled plasma-mass spectrometry for provenancing purposes - A review

被引:62
|
作者
Balcaen, L. [1 ]
Moens, L. [1 ]
Vanhaecke, F. [1 ]
机构
[1] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
关键词
Isotope ratio; Provenancing; Inductively coupled plasma mass spectrometry (ICP-MS); Multi-collector; MC-ICP-MS; DYNAMIC REACTION CELL; LEAD-ISOTOPE; STABLE-ISOTOPE; GEOGRAPHICAL ORIGIN; PRECISE DETERMINATION; ATMOSPHERIC LEAD; MAGNETIC-SECTOR; TRACE-ELEMENTS; SR ISOTOPES;
D O I
10.1016/j.sab.2010.06.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Since considerable time, isotopic analysis of different elements present in a sample, material or object (such as the 'light' elements H, C, N, O and S and 'heavy' elements, such as Sr and Pb), has been used in provenancing studies, as several factors defined by "the environment" or origin of the sample can lead to measurable differences in their isotopic composition. For the light elements, traditionally, (gas source) isotope ratio mass spectrometry (IR-MS) is used, while for a long period of time, thermal ionization mass spectrometry (TIMS) was considered as the only technique capable of detecting subtle variations in the isotopic composition of the 'heavier' elements. However, since the introduction of the first inductively coupled plasma mass spectrometers (ICP-MS), considerable attention has been devoted to the development of methodologies and strategies to perform isotopic analysis by means of ICP-MS. While the relatively modest isotope ratio precision offered by single-collector ICP-MS may already be fit-for-purpose under some circumstances, especially the introduction of multi-collector ICP-MS instruments, equipped with an array of Faraday detectors instead of a single electron multiplier, has lead to tremendous improvements in the field of isotopic analysis. As a result, MC-ICP-MS can be seen as a very strong competitor of TIMS nowadays, while it even provides information on the small isotopic variations shown by some elements, that are not or hardly accessible by means of TIMS (e.g., elements with a high ionization energy). Owing to these new instrumental developments, the application field of isotopic analysis by means of ICP-MS is continuously growing, also in the field of provenance determination. This paper is intended as a review of the developments in and the recent applications of isotopic analysis by means of ICP-MS in this specific research field. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:769 / 786
页数:18
相关论文
共 50 条
  • [21] DETERMINATION OF LEAD AND STRONTIUM ISOTOPE RATIOS IN WINES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Dehelean, A.
    Voica, C.
    ROMANIAN JOURNAL OF PHYSICS, 2012, 57 (7-8): : 1194 - 1203
  • [22] Determination of lead isotope ratios in geological samples by inductively coupled plasma mass spectrometry
    Hu, SH
    Yang, W
    Shuai, Q
    Liu, YS
    Lin, SL
    Gao, S
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (01): : 55 - 57
  • [23] Determination of lead and lead isotope ratios in gasoline by inductively coupled plasma mass spectrometry
    Lord III, Charles J.
    Journal of analytical atomic spectrometry, 1994, 9 (05): : 599 - 603
  • [24] THE APPLICATION OF ISOTOPE-DILUTION TO INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    LONGERICH, HP
    ATOMIC SPECTROSCOPY, 1989, 10 (04) : 112 - 115
  • [25] Sulfur analysis by inductively coupled plasma-mass spectrometry: A review
    Giner Martinez-Sierra, J.
    Galilea San Bias, O.
    Marchante Gayon, J. M.
    Garcia Alonso, J. I.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 108 : 35 - 52
  • [26] Heavy metals in aromatic spices by inductively coupled plasma-mass spectrometry
    Bua, Daniel Giuseppe
    Annuario, Giovanni
    Albergamo, Ambrogina
    Cicero, Nicola
    Dugo, Giacomo
    FOOD ADDITIVES & CONTAMINANTS PART B-SURVEILLANCE, 2016, 9 (03): : 210 - 216
  • [27] DETERMINATION OF MERCURY ISOTOPE RATIOS IN SAMPLES CONTAINING SUBNANOGRAM AMOUNTS OF MERCURY USING INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    HARALDSSON, C
    LYVEN, B
    OHMAN, P
    MUNTHE, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) : 1229 - 1232
  • [28] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY FOR THE ANALYSIS OF METALS ON MEMBRANE FILTERS
    NORTHINGTON, DJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (12): : 977 - 979
  • [29] Determination of lead isotope ratios in uranium mine products in South Africa by means of inductively coupled plasma mass spectrometry
    Manny Mathuthu
    Ntokozo Khumalo
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 315 : 1 - 12
  • [30] Determination of lead isotope ratios in uranium mine products in South Africa by means of inductively coupled plasma mass spectrometry
    Mathuthu, Manny
    Khumalo, Ntokozo
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 315 (01) : 1 - 12