Scintillating fiber hodoscopes using position-sensitive photomultipliers

被引:8
|
作者
Agoritsas, V
Akchurin, N
Bing, O
Braver, A
Cardini, A
DiGirolamo, B
Ditta, J
Dufournaud, J
Flaminio, V
Gorin, AM
Khaustov, P
Kuroda, K
Manuilov, IV
Okada, K
Onel, Y
Penzo, A
Rappazzo, GF
Riazantsev, AV
Rykalin, VI
Sasaki, M
Sillou, D
Takeutchi, F
TarebReyes, M
Yoshida, T
机构
[1] CERN,DIV PS BD,CH-1211 GENEVA 23,SWITZERLAND
[2] ANNECY LAPP,IN2P3,ANNECY,FRANCE
[3] UNIV IOWA,IOWA CITY,IA
[4] KYOTO SANGYO UNIV,KYOTO,JAPAN
[5] UNIV MESSINA,IST NAZL FIS NUCL,MESSINA,ITALY
[6] OSAKA CITY UNIV,OSAKA 558,JAPAN
[7] UNIV PISA,IST NAZL FIS NUCL,I-56100 PISA,ITALY
[8] STRASBOURG CTR RECH NUCL,STRASBOURG,FRANCE
[9] UNIV TRIESTE,IST NAZL FIS NUCL,TRIESTE,ITALY
[10] SERPUKHOV HIGH ENERGY PHYS INST,SERPUKHOV 142284,RUSSIA
[11] UNIV TOKYO,TOKYO,JAPAN
关键词
D O I
10.1016/0168-9002(95)01023-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present some of the recent results of an R&D program on scintillating fibers readout by position-sensitive photomultiplier tubes. Considerable improvements have been achieved compared to the previous studies, in particular in detection efficiency (>95%) and linearity. In addition, a detailed study on two-hit resolution enabled us to confirm the possibility of reconstructing double-hit events in real-time by using the delay-line method.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [1] Scintillating fiber hodoscopes using position-sensitive photomultipliers (vol 372, pg 63, 1996)
    Agoritsas, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (02): : 343 - 343
  • [2] Scintillating fibre detectors using position-sensitive photomultipliers
    Agoritsas, V
    Akchurin, N
    Bergdolt, AM
    Bing, O
    Bravar, A
    Cardini, A
    Ditta, J
    Dolinski, S
    Drevenak, R
    Dufournaud, J
    Finger, M
    Finger, M
    Flaminio, V
    DiGirolamo, B
    Giacomich, R
    Gorin, AM
    Hess, R
    Khaustov, P
    Kuroda, K
    Manuilov, IV
    Michalowicz, A
    Newsom, C
    Okada, K
    Okusawa, K
    Onel, Y
    Penzo, A
    Rapin, D
    Rappazzo, GF
    Riazantsev, AV
    Rykalin, VI
    Salvato, G
    Schiavon, P
    Sillou, D
    Slunecka, M
    Takeutchi, F
    TarebReyes, M
    Yoshida, T
    NUCLEAR PHYSICS B, 1995, : 323 - 331
  • [3] FAST READOUT OF SCINTILLATING-FIBER ARRAYS USING POSITION-SENSITIVE PHOTOMULTIPLIERS
    AGORITSAS, V
    AKCHURIN, N
    BERGDOLT, AM
    BRAVAR, A
    BING, O
    DITTA, J
    DUFOURNAUD, J
    GIACOMICH, R
    GORIN, AM
    KURODA, K
    MAGAUDDA, D
    MANUILOV, IV
    MICHALOWICZ, A
    NEWSOM, C
    OKADA, K
    OKUSAWA, K
    ONEL, Y
    PENZO, A
    RIAZANTSEV, AV
    RYKALIN, VI
    SALVATO, G
    SCHIAVON, P
    SILLOU, D
    TAKEUTCHI, F
    TAREBREYES, M
    YOSHIDA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (01): : 78 - 86
  • [4] FAST READOUT OF SCINTILLATING FIBERS USING POSITION-SENSITIVE PHOTOMULTIPLIERS
    GORIN, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (01): : 220 - 227
  • [5] STUDIES OF POSITION-SENSITIVE PHOTOMULTIPLIERS IN READOUT OF SCINTILLATING AND WAVESHIFTING FIBERS
    MAJEWSKI, S
    KROSS, B
    WOJCIK, R
    WEISENBERGER, A
    ZORN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 323 (1-2): : 489 - 504
  • [6] TESTS OF CROSSED-WIRE POSITION-SENSITIVE PHOTOMULTIPLIERS FOR SCINTILLATING-FIBER PARTICLE TRACKING
    PERDRISAT, CF
    DAY, A
    KOECHNER, D
    KROSS, B
    MAJEWSKI, S
    POURANG, R
    PUNJABI, V
    RAINE, D
    WEISENBERGER, A
    WILSON, CD
    WOJCIK, R
    ZORN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (2-3): : 378 - 384
  • [7] A SCINTILLATING-FIBER HODOSCOPE USING A POSITION-SENSITIVE PHOTOMULTIPLIER
    KURODA, K
    LEHAR, F
    MAKINO, S
    MICHALOWICZ, A
    PENZO, A
    TAKEUTCHI, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02): : 259 - 267
  • [8] Fast readout of scintilating fiber arrays using position-sensitive photomultipliers
    Agorrisas, V.
    Akchurin, N.
    Bergdol, A.M.
    Bravar, A.
    Bing, O.
    Ditta, J.
    Dufournaud, J.
    Gaconmich, R.
    Gorin, A.M.
    Kuroda, K.
    Magaudda, D.
    Manuilov, I.V.
    Michalowicz, A.
    Newson, C.
    Okada, K.
    Okusawa, K.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 357 (01):
  • [9] TEST OF FIBER DETECTOR READOUT BY POSITION-SENSITIVE PHOTOMULTIPLIERS
    BAHR, J
    HILLER, K
    HOFFMANN, B
    LUDECKE, H
    NAHNHAUER, R
    MENCHIKOV, A
    POHL, M
    ROLOFF, HE
    VOLKERT, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 713 - 718
  • [10] Neutron imaging device using position-sensitive photomultipliers
    Kuroda, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 280 - 286