An Ideal strain gage placement plan for structural health monitoring under seismic loadings

被引:7
作者
Vafaei, Mohammadreza [1 ]
Alih, Sophia C. [1 ]
机构
[1] Univ Teknol Malaysia, Fac Civil Engn, Johor Baharu, Malaysia
关键词
structural health monitoring; strain gage; sensor placement; airport traffic control tower; performance based seismic design; OPTIMAL SENSOR PLACEMENT; IDENTIFICATION; METHODOLOGY; LOCATIONS; DAMAGE;
D O I
10.12989/eas.2015.8.3.541
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Structural Health Monitoring (SHM) systems can provide valuable information regarding the safety of structures during and after ground motions which can be used by authorities to reduce post-earthquake hazards. Strain gages as a key element play an important role in the success of SHM systems. Reducing the number of required strain gages while keeping the efficiency of SHM system not only can reduce the cost of structural health monitoring but also avoids storage and process of uninformative data. In this study, a method based on performance based seismic design of structures is proposed for ideal placement of stain gages in structures. The robustness and efficiency of the proposed method is demonstrated through installation of strain gages on an Airport Traffic Control (ATC) Tower. The obtained results show that the number of required strain gages decrease significantly.
引用
收藏
页码:541 / 553
页数:13
相关论文
共 13 条
[1]  
[Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
[2]   SEISMIC PERFORMANCE ANALYSIS OF WENCHUAN HOSPITAL STRUCTURE WITH VISCOUS DAMPERS [J].
Chew, Xue-Wei ;
Li, Jia-Xuan ;
Cheang, Jack .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2010, 19 (04) :397-419
[3]  
Computers and Structures Inc., 2006, PERF 3D VERS 4 NONL
[4]   A Bayesian approach to optimal sensor placement for structural health monitoring with application to active sensing [J].
Flynn, Eric B. ;
Todd, Michael D. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2010, 24 (04) :891-903
[5]   Optimal sensor locations for structural vibration measurements [J].
Li, ZN ;
Tang, J ;
Li, QS .
APPLIED ACOUSTICS, 2004, 65 (08) :807-818
[6]   Optimal sensor placement for spatial lattice structure based on genetic algorithms [J].
Liu, Wei ;
Gao, Wei-cheng ;
Sun, Yi ;
Xu, Min-jian .
JOURNAL OF SOUND AND VIBRATION, 2008, 317 (1-2) :175-189
[7]   Optimal sensor placement methodology for parametric identification of structural systems [J].
Papadimitriou, C .
JOURNAL OF SOUND AND VIBRATION, 2004, 278 (4-5) :923-947
[8]   Identification of damage in reinforced concrete structures from earthquake records - Optimal location of sensors [J].
Skjaeraek, PS ;
Nielsen, SRK ;
Cakmak, AS .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 1996, 15 (06) :347-358
[9]   METHODOLOGY FOR OPTIMUM SENSOR LOCATIONS FOR PARAMETER-IDENTIFICATION IN DYNAMIC-SYSTEMS [J].
UDWADIA, FE .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1994, 120 (02) :368-390
[10]   Seismic performance evaluation of an airport traffic control tower through linear and nonlinear analysis [J].
Vafaei, Mohammadreza ;
bin Adnan, Azlan ;
Abd Rahman, Ahmad Baharuddin .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2014, 10 (08) :963-975