Capillary zone electrophoresis with electrochemical detection for the determination of glutathione in human red blood cells without preseparation of hemoglobin

被引:7
作者
Jin, WR [1 ]
Li, W
Xu, Q
机构
[1] Shandong Univ, Sch Chem, Analyt Sci Lab, Jinan 250100, Peoples R China
[2] Hlth & Dis Prevent Ctr Shandong Province, Jinan 250014, Peoples R China
[3] Anim Husbandry Vur Shandong Province, Jinan 250012, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1093/chromsci/38.12.545
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Interference is studied for the determination of glutathione (GSH) in human red blood cells by using capillary zone electrophoresis with end-column amperometric detection at a gold-mercury amalgam microelectrode. It is found that when interference substances such as hemoglobin (Hb) in the hemolysate flow off from the end of the separation capillary, they can be adsorbed on the surface of the electrode and interfere with the signal of GSH. If the concentration of hemolysate is lower than 0.5% (v/v), this phenomenon can be overcome because they are adsorbed on the surface of the capillary wall and do not flow off from the capillary. A method is developed for the determination of GSH in human erythrocytes without the preseparation of Hb.
引用
收藏
页码:545 / 550
页数:6
相关论文
共 13 条
[1]  
ADAMS JD, 1987, CLIN CHEM, V33, P1675
[2]   ACETAMINOPHEN HEPATOTOXICITY [J].
BLACK, M .
ANNUAL REVIEW OF MEDICINE, 1984, 35 :577-593
[3]  
CURELLO S, 1987, CLIN CHEM, V33, P1441
[4]   DETERMINATION OF CYSTEINE AND GLUTATHIONE IN PLASMA AND BLOOD BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CHEMICALLY MODIFIED ELECTRODE CONTAINING COBALT PHTHALOCYANINE [J].
HALBERT, MK ;
BALDWIN, RP .
JOURNAL OF CHROMATOGRAPHY, 1985, 345 (01) :43-49
[5]   CAPILLARY ELECTROPHORESIS FOR DIAGNOSIS AND STUDIES OF HUMAN-DISEASE, PARTICULARLY METABOLIC DISORDERS [J].
JELLUM, E ;
THORSRUD, AK ;
TIME, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :455-465
[6]   Determination of bovine serum albumin by capillary zone electrophoresis with end-column amperometric detection at the carbon fiber microdisk array electrode [J].
Jin, WR ;
Weng, QF ;
Wu, JR .
ANALYTICA CHIMICA ACTA, 1997, 342 (01) :67-74
[7]   Determination of cysteine by capillary zone electrophoresis with end-column amperometric detection at a gold/mercury amalgam microelectrode without deoxygenation [J].
Jin, WR ;
Wang, Y .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :307-314
[8]   Capillary zone electrophoresis with end-column amperometric detection for the determination of glutathione at a gold/mercury amalgam microelectrode without deoxygenation [J].
Jin, WR ;
Wang, Y .
ANALYTICA CHIMICA ACTA, 1997, 343 (03) :231-239
[9]   QUANTITATIVE-DETERMINATION OF NATIVE PROTEINS IN INDIVIDUAL HUMAN ERYTHROCYTES BY CAPILLARY ZONE ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE DETECTION [J].
LEE, TT ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :3045-3051
[10]  
LING BL, 1991, ANAL CHIM ACTA, V255, P283