Frequency-Offset Self-Injection-Locked Radar With Digital Frequency Demodulation for SNR Improvement, Elimination of EMI Issue, and DC Offset Calibration

被引:17
作者
Juan, Pin-Hsun [1 ]
Chen, Kuan-Hung [1 ]
Wang, Fu-Kang [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung 80424, Taiwan
关键词
Radar; Demodulation; Electromagnetic interference; Doppler radar; Clutter; Oscillators; Computer architecture; DC offset; electromagnetic interference (EMI); frequency demodulation; frequency-offset technique; low intermediate frequency (IF); self-injection-locked (SIL) radar; vital sign; CONCURRENT VITAL SIGN; CANCELLATION; SYNTHESIZER; DETECTOR; SENSOR; IF;
D O I
10.1109/TMTT.2020.3039780
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The proposed frequency-offset self-injection-locked (FOSIL) radar combines two independent SIL radar front-ends with up/down-mixers. The transmit frequency can be held constant by properly adjusting the injection phases and amplitudes of two oscillators. Therefore, electromagnetic interference (EMI) in the monitoring of a moving subject using conventional SIL radars is eliminated, and multiple FOSIL radars can be operated simultaneously within a limited bandwidth. In this work, one RF mixer with digital frequency demodulation is used to extract the motion of the target relative to the radar, reducing the system complexity and eliminating the I/ Q imbalance and dc offset calibration. The proposed system substantially improves the SNR over that of the conventional SIL radar by 28 dB, by mitigating the flicker noise and the large Doppler shift. In noncontact vital sign sensing experiments, the 5.8-GHz industrial scientific medical (ISM) band FOSIL radar prototype had a sensing range of 8 m, and its frequency swing range was reduced by over 96% without or with clutter signals. Two FOSIL radars with a frequency spacing of 2 MHz can yield exact information on the cardiopulmonary activities of two subjects at the same time in the experimental environment.
引用
收藏
页码:1149 / 1160
页数:12
相关论文
共 30 条
  • [1] Changyu Wei, 2015, 2015 IEEE MTT-S International Microwave Symposium (IMS2015), P1, DOI 10.1109/MWSYM.2015.7167109
  • [2] 60-GHz CMOS Doppler Radar Sensor With Integrated V-Band Power Detector for Clutter Monitoring and Automatic Clutter-Cancellation in Noncontact Vital-Signs Sensing
    Chou, Chien-Chang
    Lai, Wen-Chian
    Hsiao, Yi-Kai
    Chuang, Huey-Ru
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (03) : 1635 - 1643
  • [3] Radius Correction Technique for Doppler Radar Noncontact Periodic Displacement Measurement
    Gao, Xiaomeng
    Boric-Lubecke, Olga
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (02) : 621 - 631
  • [4] Instrument-Based Noncontact Doppler Radar Vital Sign Detection System Using Heterodyne Digital Quadrature Demodulation Architecture
    Gu, Changzhan
    Li, Changzhi
    Lin, Jenshan
    Long, Jiang
    Huangfu, Jiangtao
    Ran, Lixin
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (06) : 1580 - 1588
  • [5] Automated DC Offset Calibration Strategy for Structural Health Monitoring Based on Portable CW Radar Sensor
    Guan, Shanyue
    Rice, Jennifer A.
    Li, Changzhi
    Gu, Changzhan
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (12) : 3111 - 3118
  • [6] Noninvasive Measurement and Analysis of Laboratory Rat's Cardiorespiratory Movement
    Huang, Tien-Yu
    Hayward, Linda F.
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (02) : 574 - 581
  • [7] Juan PH, 2020, IEEE MTT S INT MICR, P643, DOI 10.1109/IMS30576.2020.9224009
  • [8] Design and Analysis of a 60-GHz CMOS Doppler Micro-Radar System-in-Package for Vital-Sign and Vibration Detection
    Kao, Te-Yu J.
    Yan, Yan
    Shen, Tze-Min
    Chen, Austin Ying-Kuang
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (04) : 1649 - 1659
  • [9] A 3-to-8-GHz fast-hopping frequency synthesizer in 0.18-/μm CMOS technology
    Lee, J
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2006, 41 (03) : 566 - 573
  • [10] Experiment and spectral analysis of a low-power Ka-band heartbeat detector measuring from four sides of a human body
    Li, Changzhi
    Xiao, Yanming
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (12) : 4464 - 4471