Ultrasensitive flow-injection electrochemical method for determination of histamine in tuna fish samples

被引:26
作者
Akbari-adergani, Behrouz [1 ]
Norouzi, Parviz [2 ,3 ]
Ganjali, Mohammad Reza [2 ,3 ]
Dinarvand, Rassoul [4 ]
机构
[1] Food & Drug Labs Res Ctr, Minist Hlth & Med Educ, Tehran, Iran
[2] Univ Tehran, Ctr Excellence Electrochem, Fac Chem, Tehran, Iran
[3] Med Sci Univ Tehran, Endocrinol & Metab Res Ctr, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Pharmaceut, Fac Pharm, Tehran, Iran
关键词
Histamine; Tuna fish; Electrochemical detection; Flow-injection analysis; Cyclic voltammetry; CONTINUOUS CYCLIC VOLTAMMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; AMPEROMETRIC DETECTION; AU MICROELECTRODE; LEVEL; ELECTRODE; PRODUCTS; TABLETS; SENSOR;
D O I
10.1016/j.foodres.2010.02.007
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Histamine is a potentially hazardous compound and one of the major concerns in food chemistry. High amount of histamine may be found in food as a consequence of the use of poor quality raw materials, contamination and inappropriate conditions during food processing and storage. A novel method for the determination of histamine in flow-injection systems has been developed for use in seafood quality inspection and food quality control laboratories. The developed technique is very simple, precise, accurate, time saving and economic as compared to all of the previously reported methods. The effects of various parameters on the sensitivity of the method were investigated. The best performance was obtained with the conditions, pH value of 2.0, and sweep rate value of 40 V/s, accumulation potential of 900 mV and accumulation time of 0.4 s. In this work, we introduce a special computer based numerical method, for calculation of the analyte signal and noise reduction. The electrode response was calculated based on partial and total charge exchanges at the electrode surface after subtracting the background current from noise. The waveform potential consisting of potential steps for cleaning and accumulation of analyte, and potential ramp was applied on an Au disk microelectrode (with a radius of 12.5 mu m). The method was linear over the concentration range of 1.1-5555 pg/ml (r = 0.998) with a limit of detection and quantification 0.35 and 1.16 pg/ml, respectively. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1116 / 1122
页数:7
相关论文
共 40 条
[1]   High performance liquid chromatography method for determination of methyl-5-benzoyl-2-benzimidazole carbamate (mebendazole) and its main degradation product in pharmaceutical dosage forms [J].
Al-Kurdi, Z ;
Al-Jallad, T ;
Badwan, A ;
Jaber, AMY .
TALANTA, 1999, 50 (05) :1089-1097
[2]   Porphyrins as carriers in poly(vinyl chloride)-based membrane potentiometric sensors for histamine [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYST, 1999, 124 (09) :1319-1322
[3]  
ARNOLD SH, 1978, ADV FOOD RES, V34, P113
[4]   High-frequency impedance spectroscopy of platinum ultramicroelectrodes in flowing solutions [J].
Baranski, AS ;
Krogulec, T ;
Nelson, LJ ;
Norouzi, P .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2895-2901
[5]  
Bockris J.O'M., 1980, COMPR TREAT, V1
[6]   A SENSITIVE AND SPECIFIC RADIOMETRIC METHOD FOR THE MEASUREMENT OF PLASMA HISTAMINE IN NORMAL INDIVIDUALS [J].
BROWN, MJ ;
IND, PW ;
BARNES, PJ ;
JENNER, DA ;
DOLLERY, CT .
ANALYTICAL BIOCHEMISTRY, 1980, 109 (01) :142-146
[7]   Determination of histamine by high-pH anion-exchange chromatography with electrochemical detection [J].
Casella, IG ;
Gatta, M ;
Desimoni, E .
FOOD CHEMISTRY, 2001, 73 (03) :367-372
[8]   Validation and comparison of analytical methods for the determination of histamine in tuna fish samples [J].
Cinquina, AL ;
Longo, F ;
Calì, A ;
De Santis, L ;
Baccelliere, R ;
Cozzani, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :79-85
[9]   Fourier transform cyclic voltammetric technique for monitoring ultratrace amounts of salbutamol at gold ultra microelectrode in flowing solutions [J].
Ganjali, MR ;
Norouzi, P ;
Ghorbani, M ;
Sepehri, A .
TALANTA, 2005, 66 (05) :1225-1233
[10]   The effect of storage temperature on histamine production and the freshness of yellowfin tuna (Thunnus albacares) [J].
Guizani, N ;
Al-Busaidy, MA ;
Al-Belushi, IM ;
Mothershaw, A ;
Rahman, MS .
FOOD RESEARCH INTERNATIONAL, 2005, 38 (02) :215-222