Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex

被引:38
作者
Wilson, JL [1 ]
Jezzard, P [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, FMRIB Ctr, Dept Clin Neurol, Oxford OX3 9DU, England
关键词
passive shimming; fMRI; susceptibility artifact; inferior frontal cortex; BOLD;
D O I
10.1002/mrm.10626
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the presence of gross magnetic susceptibility artifacts, functional MRI (fMRI) has proved problematic in studies of the human inferior frontal cortex (IFC). There is a strong desire, therefore, to employ techniques that mitigate susceptibility artifacts in the IFC while preserving the imaging parameters of an MRI study. It has been shown that the use of a single, strongly diamagnetic, intra-oral passive shim significantly improves the homogeneity of the static magnetic field (B-0) and, as a result, alleviates the susceptibility artifacts within the IFC. In this study, practical issues regarding the use of an intra-oral passive shim are examined. We investigated B-0 instabilities within the IFC resulting from subject head motion in order to calculate the effects of an intra-oral passive shim on the temporal variance of an EPI time series. These studies show that the addition of an intra-oral passive shim improves both B-0 homogeneity and signal stability, and increases sensitivity to functional activation. Magn Reson Med 50:1089-1094, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1089 / 1094
页数:6
相关论文
共 18 条
[1]   Modeling geometric deformations in EPI time series [J].
Andersson, JLR ;
Hutton, C ;
Ashburner, J ;
Turner, R ;
Friston, K .
NEUROIMAGE, 2001, 13 (05) :903-919
[2]   Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head [J].
Collins, CM ;
Yang, B ;
Yang, QX ;
Smith, MB .
MAGNETIC RESONANCE IMAGING, 2002, 20 (05) :413-424
[3]  
DARCY RCN, 2002, P 10 ANN M ISMRM HON, P1408
[4]   Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI Imaging [J].
Deichmann, R ;
Josephs, O ;
Hutton, C ;
Corfield, DR ;
Turner, R .
NEUROIMAGE, 2002, 15 (01) :120-135
[5]   Image distortion correction in fMRI: A quantitative evaluation [J].
Hutton, C ;
Bork, A ;
Josephs, O ;
Deichmann, R ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2002, 16 (01) :217-240
[6]  
Jenkinson M, 2001, NEUROIMAGE, V13, pS165
[7]  
JENKINSON M, 2002, P 10 ANN M ISMRM HON, P2325
[8]  
Jezzard P, 1999, HUM BRAIN MAPP, V8, P80, DOI 10.1002/(SICI)1097-0193(1999)8:2/3<80::AID-HBM2>3.0.CO
[9]  
2-C
[10]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73