First-Pass Perfusion Cardiac MRI Using the Partially Separable Functions Model with Generalized Support

被引:3
作者
Brinegar, Cornelius [1 ]
Zhang, Haosen [2 ]
Wu, Yi-Jen L. [2 ]
Foley, Lesley M. [2 ]
Hitchens, T. Kevin [2 ]
Ye, Qing [2 ]
Ho, Chien [2 ]
Liang, Zhi-Pei [1 ]
机构
[1] Univ Illinois, Dept Elect & Comp Engn, 1406 W Green St, Urbana, IL 61801 USA
[2] Carnegie Mellon Univ, Pittsburg NMR Ctr, Biomed Res, Dept Biol Sci, Pittsburgh, PA 15213 USA
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
K-T BLAST; MYOCARDIAL-PERFUSION; RECONSTRUCTION; SENSE;
D O I
10.1109/IEMBS.2010.5626078
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic imaging methods based on the Partially Separable Functions (PSF) model have been used to perform ungated cardiac MRI, and the critical parameter determining the quality of the reconstructed images is the order, L, of the PSF model. This work extends previous methods by increasing L in the cardiac region to improve the ability of the PSF model to represent complex spatiotemporal signals. The resulting higher order PSF model is fit to sparse (k, t)-space data using spatial-spectral support, spatial-eigenbasis support, and spectral sparsity constraints. This new method is demonstrated in the context of 2D first-pass perfusion MRI in a healthy rat heart.
引用
收藏
页码:2833 / 2836
页数:4
相关论文
共 15 条
[1]  
Biederman RW, 2008, CARDIOVASCULAR MRI T
[2]   Real-Time Cardiac MRI Without Triggering, Gating, or Breath Holding [J].
Brinegar, Cornelius ;
Wu, Yi-Jen L. ;
Foley, Lesley M. ;
Hitchens, T. Kevin ;
Ye, Qing ;
Ho, Chien ;
Liang, Zhi-Pei .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :3381-+
[3]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[4]   Cardiac MR imaging: State of the technology [J].
Finn, J. Paul ;
Nael, Kambiz ;
Deshpande, Vibhas ;
Ratib, Osman ;
Laub, Gerhard .
RADIOLOGY, 2006, 241 (02) :338-354
[5]   Sparse signal reconstruction from limited data using FOCUSS: A re-weighted minimum norm algorithm [J].
Gorodnitsky, IF ;
Rao, BD .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (03) :600-616
[6]   Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE [J].
Kellman, P ;
Derbyshire, JA ;
Agyeman, KO ;
McVeigh, ER ;
Arai, AE .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :200-204
[7]  
Liang ZP, 2007, I S BIOMED IMAGING, P988
[8]   Cardiac magnetic resonance perfusion imaging identifies transplant arteriopathy by a reduced endomyocardial resting perfusion [J].
Muehling, OM ;
Panse, P ;
Jerosch-Herold, M ;
Wilson, BV ;
Wilson, RF ;
Wilke, NM ;
Miller, LW .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (08) :1122-1123
[9]   k-t PCA: Temporally Constrained k-t BLAST Reconstruction Using Principal Component Analysis [J].
Pedersen, Henrik ;
Kozerke, Sebastian ;
Ringgaard, Steffen ;
Nehrke, Kay ;
Kim, Won Yong .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) :706-716
[10]   Dynamic contrast-enhanced myocardial perfusion MRI accelerated with k-t SENSE [J].
Plein, Sven ;
Ryf, Salome ;
Schwitter, Juerg ;
Radjenovic, Aleksandra ;
Boesiger, Peter ;
Kozerke, Sebastian .