Comparison of dose volume parameters evaluated using three forward planning - optimization techniques in cervical cancer brachytherapy involving two applicators

被引:10
|
作者
Chakrobarti, Bikramjit [1 ,2 ]
Basu-Roy, Somapriya
Kar, Sanjay Kumar
Das, Sounik
Lahiri, Annesha
机构
[1] Inst Postgrad Med Educ & Res, Dept Radiotherapy, Kolkata 700020, India
[2] Seth Sukhlal Kernani Mem Hosp, Kolkata 700020, India
关键词
cervical cancer; cervix; carcinoma; dosimetry; optimization; INTRACAVITARY BRACHYTHERAPY; AMERICAN BRACHYTHERAPY; COMPUTED-TOMOGRAPHY; MRI; RECOMMENDATIONS; BLADDER; GUIDELINES; CARCINOMA; ANATOMY; TANDEM;
D O I
10.5114/jcb.2017.70677
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study is intended to compare dose-volume parameters evaluated using different forward planning optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose rate (HDR) fractionation schedules. Material and methods: We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times ('no optimization'), 'manual dwell weight/times', and 'graphical'. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results: Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D-2cc) rectum and rectal point etc.; D-2cc, minimum, maximum, median, and average dose to sigmoid colon; D-2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions: Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced.
引用
收藏
页码:431 / 445
页数:15
相关论文
共 50 条
  • [21] Comparison of two inverse planning algorithms for cervical cancer brachytherapy
    Fu, Qi
    Xu, Yingjie
    Zuo, Jing
    An, Jusheng
    Huang, Manni
    Yang, Xi
    Chen, Jiayun
    Yan, Hui
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 157 - 165
  • [22] Toxicities and dose-volume histogram parameters of MRI-based brachytherapy for cervical cancer
    Kim, Youngkyong
    Kim, Yeon-Joo
    Kim, Joo-Young
    Lim, Young Kyung
    Jeong, Chiyoung
    Jeong, Jonghwi
    Kim, Meyoung
    Lim, Myong Cheol
    Seo, Sang-Soo
    Park, Sang-Yoon
    BRACHYTHERAPY, 2017, 16 (01) : 116 - 125
  • [23] Automated treatment planning framework for brachytherapy of cervical cancer using 3D dose predictions
    Kallis, Karoline
    Moore, Lance C.
    Cortes, Katherina G.
    Brown, Derek
    Mayadev, Jyoti
    Moore, Kevin L.
    Meyers, Sandra M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (08)
  • [24] A comparison of dosimetric parameters in high-dose-rate intracavitary brachytherapy using tandem and ring applicators: is the combination of a rectal retractor and radio-opaque vaginal packing better than rectal retractor alone for rectum sparing in cervical cancer?
    Vats, Siddarth
    Thakur, Shabnum
    Sharma, Mukesh
    Gupta, Manish
    Chandrakant, Lalit
    Negi, Muninder
    Verma, Swati
    Negi, Anup
    Kumar, Vivek
    Sharma, Parul
    Negi, Rattan Mahesh
    ECANCERMEDICALSCIENCE, 2022, 16
  • [25] SINGLE VERSUS CUSTOMIZED TREATMENT PLANNING FOR IMAGE-GUIDED HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL CANCER: DOSIMETRIC COMPARISON AND PREDICTING FACTOR FOR ORGANS AT RISK OVERDOSE WITH SINGLE PLAN APPROACH
    Chi, Alexander
    Gao, Mingcheng
    Sinacore, James
    Nguyen, Nam P.
    Vali, Faisal
    Albuquerque, Kevin
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 309 - 314
  • [26] Outcomes and dose-volume parameters for computed tomography-based brachytherapy planning for vaginal recurrence of uterine cancer primarily treated with surgery
    Murofushi, Keiko Nemoto
    Tanaka, Reiko
    Ohkawa, Ayako
    Numajiri, Haruko
    Okumura, Toshiyuki
    Sakurai, Hideyuki
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2021, 48 (03) : 601 - 606
  • [27] Interstitial preoperative high-dose-rate brachytherapy for early stage cervical cancer: Dose-volume histogram parameters, pathologic response and early clinical outcome
    Hannoun-Levi, Jean-Michel
    Chand-Fouche, Marie-Eve
    Gautier, Mathieu
    Dejean, Catherine
    Marcy, Myriam
    Fouche, Yves
    BRACHYTHERAPY, 2013, 12 (02) : 148 - 155
  • [28] Comparison of dose delivered to vagina using two different intracavitary brachytherapy applicators for carcinoma cervix
    Bajwa, Harjot Kaur
    Talluri, Anil Kumar
    Maqbool, Aijaz
    Reddy, Devender
    Singareddy, Rohith
    Sresty, N. V. N. Madhusudhana
    Raju, Alluri Krishnam
    BRACHYTHERAPY, 2022, 21 (02) : 151 - 157
  • [29] Effect of Hyaluronate Acid Injection on Dose-Volume Parameters in Brachytherapy for Cervical Cancer
    Kobayashi, Rei
    Murakami, Naoya
    Chiba, Takahito
    Okuma, Kae
    Inaba, Koji
    Takahashi, Kana
    Kaneda, Tomoya
    Kashihara, Tairo
    Takahashi, Ayaka
    Shimizu, Yuri
    Nakayama, Yuko
    Kato, Tomoyasu
    Ito, Yoshinori
    Igaki, Hiroshi
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (03)
  • [30] Dosimetric comparison of manual forward planning with uniform dwell times versus volume-based inverse planning in interstitial brachytherapy of cervical malignancies
    Palled, Siddanna R.
    Radhakrishna, Nikhila K.
    Manikantan, Senthil
    Khanum, Hashmath
    Venugopal, Bindu K.
    Vishwanath, Lokesh
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 851 - 855