Comparison of dose volume parameters evaluated using three forward planning - optimization techniques in cervical cancer brachytherapy involving two applicators

被引:10
|
作者
Chakrobarti, Bikramjit [1 ,2 ]
Basu-Roy, Somapriya
Kar, Sanjay Kumar
Das, Sounik
Lahiri, Annesha
机构
[1] Inst Postgrad Med Educ & Res, Dept Radiotherapy, Kolkata 700020, India
[2] Seth Sukhlal Kernani Mem Hosp, Kolkata 700020, India
关键词
cervical cancer; cervix; carcinoma; dosimetry; optimization; INTRACAVITARY BRACHYTHERAPY; AMERICAN BRACHYTHERAPY; COMPUTED-TOMOGRAPHY; MRI; RECOMMENDATIONS; BLADDER; GUIDELINES; CARCINOMA; ANATOMY; TANDEM;
D O I
10.5114/jcb.2017.70677
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study is intended to compare dose-volume parameters evaluated using different forward planning optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose rate (HDR) fractionation schedules. Material and methods: We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times ('no optimization'), 'manual dwell weight/times', and 'graphical'. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results: Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D-2cc) rectum and rectal point etc.; D-2cc, minimum, maximum, median, and average dose to sigmoid colon; D-2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions: Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced.
引用
收藏
页码:431 / 445
页数:15
相关论文
共 50 条
  • [1] High-dose-rate brachytherapy using inverse planning optimization with tandem and ovoid applicators for locally advanced cervical cancer: a simulation study
    Yaegashi, Yuji
    Sasaki, Kohei
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (03) : 262 - 270
  • [2] Correlation Between Bladder Volume and Irradiated Dose of Small Bowel in CT-based Planning of Intracavitary Brachytherapy for Cervical Cancer
    Yamashita, Hideomi
    Nakagawa, Keiichi
    Okuma, Kae
    Sakumi, Akira
    Haga, Akihiro
    Kobayashi, Reiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2012, 42 (04) : 302 - 308
  • [3] Prospective comparison of rectal dose reduction during intracavitary brachytherapy for cervical cancer using three rectal retraction techniques
    Kong, Iwa
    Vorunganti, Sachi
    Patel, Malti
    Farrell, Thomas
    Timotin, Emilia
    Quinlan-Davidson, Sean
    Pond, Greg
    Sur, Ranjan
    Hunter, Robert
    BRACHYTHERAPY, 2016, 15 (04) : 450 - 455
  • [4] Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer
    Kirisits, C
    Pötter, R
    Lang, S
    Dimopoulos, J
    Wachter-Gerstner, N
    Georg, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03): : 901 - 911
  • [5] Dosimetric comparison of two-dimensional versus three-dimensional intracavitary brachytherapy in locally advanced cervical cancer
    Klisarovska, Violeta
    Smichkoska, Snezhana
    Chakalaroski, Petar
    Krstevska, Valentina
    Dimitrovska, Nadica
    Stefanovski, Zoran
    Lazarova, Emilija
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2018, 146 (3-4) : 157 - 162
  • [6] DOSE AND VOLUME PARAMETERS FOR CT BASED TREATMENT PLANNING IN INTRACAVITARY BRACHYTHERAPY FOR CERVICAL CANCER. A COMPARISON BETWEEN 2D AND 3D BRACHYTHERAPY
    Enciu, Lucia Elena
    Constantinescu, Amalia
    Savu, Mircea
    Baranga, Gabriel
    Oprea, Alexandru
    Croitoriu, Madalina
    Busuioc, Laurentiu
    ROMANIAN REPORTS IN PHYSICS, 2018, 70 (02)
  • [7] High-dose-rate brachytherapy using inverse planning optimization with tandem and ovoid applicators for locally advanced cervical cancer: a simulation study
    Yuji Yaegashi
    Kohei Sasaki
    Radiological Physics and Technology, 2021, 14 : 262 - 270
  • [8] Dosimetric comparison of two different applicators and rectal retraction methods used in inverse optimization-based intracavitary brachytherapy for cervical cancer
    Biltekin, Fatih
    Gultekin, Melis
    Yilmaz, Melek Tugce
    Yildiz, Ferah
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (01) : 35 - 43
  • [9] DOSE-VOLUME HISTOGRAM PARAMETERS AND LOCAL TUMOR CONTROL IN MAGNETIC RESONANCE IMAGE-GUIDED CERVICAL CANCER BRACHYTHERAPY
    Dimopoulos, Johannes C. A.
    Lang, Stefan
    Kirisits, Christian
    Fidarova, Elena F.
    Berger, Daniel
    Georg, Petra
    Doerr, Wolfgang
    Poetter, Richard
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 56 - 63
  • [10] CONE BEAM CT-BASED THREE-DIMENSIONAL PLANNING IN HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL CANCER
    Al-Halabi, Hani
    Portelance, Lorraine
    Duclos, Marie
    Reniers, Brigitte
    Bahoric, Boris
    Souhami, Luis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04): : 1092 - 1097