A numerical investigation of fan wall cooling system for modular air-cooled data center

被引:29
作者
Xiong, Xin [1 ]
Fulpagare, Yogesh [1 ]
Lee, Poh Seng [1 ]
机构
[1] Natl Univ Singapore, Dept Mech Engn, 9 Engn Dr 1, Singapore 117575, Singapore
基金
新加坡国家研究基金会;
关键词
Data center; Fan wall cooling; Thermal environment; Hot aisle containment; THERMAL MANAGEMENT;
D O I
10.1016/j.buildenv.2021.108287
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Airflow management in the data center is one of the most researched topics to achieve uniform airflow for effective thermal management. Recently, the Fan Wall Cooling (FWC) system is popular in air-cooled data centers due to the advantage of no raised floor plenum. In this research, a validated CFD model is used to study the FWC performance with different configurations to gain insights for the optimum design. Five new configurations are proposed to optimize the FWC performance along with ordinary FWC. Each of them has a different rack-tilted and row-tilted angle. The results show that tilting the rack by 15 degrees towards the supply air direction can increase the rack air flowrate by 2.5% (800 CFM), and reduce the maximum normalized server temperature (T*ser,max) by 7% from 1.30 to 1.21. The CFD simulations also reveal that all new configurations can effectively mitigate the airflow maldistribution. Lastly, the FWC exhibits superior thermal performance compared to the conventional Underfloor Air Delivery (UFAD) and the Overhead Air Supply (OHAS) methods.
引用
收藏
页数:14
相关论文
共 61 条
[1]   A parametric CFD study of computer room air handling bypass in air-cooled data centers [J].
Ahmadi, Vahid Ebrahimpour ;
Erden, Hamza Salih .
APPLIED THERMAL ENGINEERING, 2020, 166
[2]  
AirWall TM, AIR FAN WALL MOD 4 1
[3]  
Alissa H.A., 2015, STEADY STATE TRANSIE, V5688
[4]  
Alissa HA, 2015, INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2015, VOL 1
[5]  
Alkharabsheh S.A., 2013, NUMERICAL STEADY STA
[6]   Experimentally Validated Computational Fluid Dynamics Model for a Data Center With Cold Aisle Containment [J].
Alkharabsheh, Sami A. ;
Sammakia, Bahgat G. ;
Shrivastava, Saurabh K. .
JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (02)
[7]  
[Anonymous], 2019, DATA CTR DESIGN SING
[8]   Thermal Characteristics of Open and Contained Data Center Cold Aisle [J].
Arghode, Vaibhav K. ;
Sundaralingam, Vikneshan ;
Joshi, Yogendra ;
Phelps, Wally .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2013, 135 (06)
[9]   Rack Level Modeling of Air Flow Through Perforated Tile in a Data Center [J].
Arghode, Vaibhav K. ;
Kumar, Pramod ;
Joshi, Yogendra ;
Weiss, Thomas ;
Meyer, Gary .
JOURNAL OF ELECTRONIC PACKAGING, 2013, 135 (03)
[10]  
Ashrae, 2012, THERM GUID DAT PROC, Vthird