Effect of visual acuity on biometry prediction error after cataract surgery

被引:15
作者
Daniel, C
Tuft, S
Ionides, A
Bunce, C
机构
[1] Inst Ophthalmol, Dept Pathol, London EC1V 9EL, England
[2] Moorfields Eye Hosp, London, England
[3] Univ London St Georges Hosp, London SW17 0RE, England
关键词
D O I
10.1016/S0886-3350(02)01913-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the effect of visual acuity on biometry prediction error. Setting: Postgraduate teaching hospital. Methods: The study was an observational case series of the first operated eye of 2149 consecutive patients who had cataract surgery. Biometry prediction error was defined as the difference between the planned refraction determined by biometry and the spherical equivalent of the final refraction. The principal outcome measure was the percentage of eyes within +/-1.00 diopter (D) of the intended refraction. This outcome was calculated for patients with visual loss caused by cataract alone, defined as eyes with a postoperative acuity of 6/6 or better, and eyes with different levels of postoperative visual acuity. Results: Complete data were available for 1978 eyes (92%). Of these, 1438 (73%) were within +/-1.00 D of the intended refraction. When the final corrected visual acuity was 6/6 or better, the percentage of eyes within +/-1.00 D of the predicted refraction was at least 78%. When the preoperative acuity was worse than 6/60, 74% in the counting fingers group and 69% in the hand movements group with a final corrected acuity of 6/6 or better were within +/-1.00 D. This trend bordered on statistical significance (P = .05). There was a rapid reduction in the percentage of eyes within +/-1.00 D of the intended refraction as the postoperative acuity decreased because of ocular comorbidity, with a statistically significant difference between eyes with a postoperative acuity of 6/6 or better and each group with an acuity of 6/9 or worse (P<.01). Conclusions: In eyes without visually significant ocular comorbidity, cataract must reduce vision to 6/60 or worse before there is an increase in biometry prediction error. In contrast, ocular comorbidity that reduces the postoperative acuity causes an early and marked increase in biometry prediction error. (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:1365 / 1369
页数:5
相关论文
共 16 条
[1]   National cataract surgery survey 1997-8. A report of the results of the clinical outcomes [J].
Desai, P ;
Minassian, DC ;
Reidy, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (12) :1336-1340
[2]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[3]   Improved prediction of intraocular lens power using partial coherence interferometry [J].
Findl, O ;
Drexler, W ;
Menapace, R ;
Heinzl, H ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (06) :861-867
[4]  
Goss D A, 1996, J Am Optom Assoc, V67, P619
[5]  
HOFFER K J, 1982, International Ophthalmology Clinics, V22, P37, DOI 10.1097/00004397-198202220-00005
[6]  
HOFFER KJ, 1994, J CATARACT REFR SURG, V20, P677
[7]  
JANSSON F, 1963, ACTA OPHTHALMOL S, P74
[8]  
KORA Y, 1991, OPHTHALMIC SURG LAS, V22, P78
[9]   1998 European Cataract Outcome Study -: Report from the European Cataract Outcome Study Group [J].
Lundström, M ;
Barry, P ;
Leite, E ;
Seward, H ;
Stenevi, U .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (08) :1176-1184
[10]   EFFECT OF KERATOMETER AND AXIAL LENGTH MEASUREMENT ERRORS ON PRIMARY IMPLANT POWER CALCULATIONS [J].
MCEWAN, JR ;
MASSENGILL, RK ;
FRIEDEL, SD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :61-70