A Biomechanical Comparison of Periprosthetic Femoral Fracture Fixation in Normal and Osteoporotic Cadaveric Bone

被引:45
作者
Demos, Harry A. [1 ]
Briones, Marcus S. [2 ]
White, Peter H. [1 ]
Hogan, Kathleen A. [3 ]
Barfield, William R. [1 ,4 ]
机构
[1] Med Univ S Carolina, Dept Orthopaed Surg, Charleston, SC 29425 USA
[2] OrthoCarolina, Monroe, NC USA
[3] New Hampshire Orthopaed Ctr, Amherst, NH USA
[4] Coll Charleston, Charleston, SC 29401 USA
关键词
periprosthetic; Vancouver B1 fracture; cadaver; biomechanics; fixation; SHAFT FRACTURES; PLATE FIXATION; HIP; COMPRESSION; CABLE; LOCKING; STEM; TIP;
D O I
10.1016/j.arth.2011.08.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Several techniques are described for fixation of Vancouver B1 femoral shaft fractures after total hip arthroplasty. Twenty-four femurs were scanned by dual x-ray absorptiometry scanned and matched for bone mineral density. Femurs were implanted with a cemented simulated total hip prosthesis with a simulated periprosthetic femur fracture distal to the stem. Fractures were fixed with Synthes (Paoli, Pa) 12-hole curved plates and 4 different constructs proximally. Each construct was loaded to failure in axial compression. Constructs with locking and nonlocking screws demonstrated equivalent loads at failure and were superior in load at failure compared with cables. Cable constructs failed proximally. No proximal failures occurred in specimens fixed with screws and cables. A combination of locked or nonlocked screws and supplemental cable fixation is recommended for the treatment of Vancouver B1 periprosthetic femur fractures.
引用
收藏
页码:783 / 788
页数:6
相关论文
共 29 条
[11]   Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate [J].
Haddad, FS ;
Duncan, CP ;
Berry, DJ ;
Lewallen, DG ;
Gross, AE ;
Chandler, HP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06) :945-950
[12]   Peri-prosthetic femoral shaft fractures treated with plate and cable fixation [J].
Kamineni, S ;
Vindlacheruvu, R ;
Ware, HE .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (04) :261-268
[13]  
Kelley, 1994, J Am Acad Orthop Surg, V2, P164
[14]  
Köse N, 2000, J ORTHOP TRAUMA, V14, P414
[15]   TELEMETERIZED INVIVO HIP-JOINT FORCE DATA - A REPORT ON 2 PATIENTS AFTER TOTAL HIP-SURGERY [J].
KOTZAR, GM ;
DAVY, DT ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
HEIPLE, KG ;
BROWN, RH ;
BURSTEIN, AH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :621-633
[16]   Three hundred and twenty-one periprosthetic femoral fractures [J].
Lindahl, Hans ;
Garellick, Goran ;
Regner, Hans ;
Herberts, Peter ;
Malchau, Henrik .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (06) :1215-1222
[17]   Periprosthetic fractures evaluation and treatment [J].
Masri, BA ;
Meek, RMD ;
Duncan, CP .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) :80-95
[18]  
Mont M A, 1994, J Arthroplasty, V9, P511, DOI 10.1016/0883-5403(94)90098-1
[19]  
Ogden WS, 1978, ORTHOP T, V2, P70
[20]   Surgical management of intra- and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty [J].
Schmotzer, H ;
Tchejeyan, GH ;
Dall, DM .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :709-717