Calibration of double focusing Glow Discharge Mass Spectrometry instruments with pin-shaped synthetic standards

被引:20
作者
Gusarova, T. [1 ,2 ]
Methven, B. [3 ]
Kipphardt, H. [2 ]
Sturgeon, R. [3 ]
Matschat, R. [2 ]
Panne, U. [1 ,2 ]
机构
[1] Humboldt Univ, Dept Chem, D-12489 Berlin, Germany
[2] BAM Fed Inst Mat Res & Testing, D-12489 Berlin, Germany
[3] NRC Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
Glow discharge; Pin sample; Calibration; ION-SOURCE; GAS-FLOW;
D O I
10.1016/j.sab.2011.12.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Calibration of two commercially available glow discharge double focusing mass spectrometers, the VG 9000 and Element GD, is described using synthetic pin standards pressed from solution doped copper and zinc matrices. A special pressing die was developed for this purpose and optimal results were obtained with the highest possible pressures, i.e., 95 kN.cm(-2). This calibration approach permits the determination of trace element mass fractions down to mu g.kg(-1) with small uncertainties and additionally provides traceability of the GD-MS results in the most direct manner to the SI (International System of Units). Results were validated by concurrent measurements of a number of compact copper and zinc certified reference materials. The impact of the sample pin cross-section (circular or square) was investigated with the use of a new pin-sample holder system for the Element GD. The pin-sample holder was designed by the manufacturer for pin-samples having circular cross-section; however, samples with square pin cross-section were also shown to provide acceptable results. Relative Sensitivity Factors for some 50 analytes in copper (VG 9000, Element GD) and zinc matrices (VG 9000) are presented. The field of applicability of GD-MS may be considerably extended via analysis of pin geometry samples based on their ease of preparation, especially with respect to the accuracy and traceability of the results and the enhanced number of analytes which can be reliably calibrated using such samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:847 / 854
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 2008, DIN 32645:2008-11
[2]  
[Anonymous], 2005, FINN EL GD HARDW MAN
[3]  
[Anonymous], CERTIFICATES REPORTS
[4]   Development and analytical characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution [J].
Beyer, C ;
Feldmann, I ;
Gilmour, D ;
Hoffmann, V ;
Jakubowski, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (10) :1521-1533
[5]   Calculation of the gas flow and its effect on the plasma characteristics for a modified Grimm-type glow discharge cell [J].
Bogaerts, A ;
Okhrimovskyy, A ;
Gijbels, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) :1076-1082
[6]  
Born S., 1999, THESIS TU CLAUSTHAL
[7]  
Brochure, BROCH FINN ELEMENT G
[8]   Commercial development of HR-ICPMS, MC-ICPMS and HR-GDMS [J].
Douthitt, Charles B. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) :685-689
[9]  
Goddard P.J., 1985, GLOW DISCHARGE MASS
[10]  
Grimm W., 1970, U.S. patent, Patent No. [3,543,077, 3543077]