Inter-tester reliability of non-invasive technique for measurement of innominate motion

被引:14
作者
Adhia, Divya Bharatkumar [2 ]
Bussey, Melanie D. [1 ]
Mani, Ramakrishnan [2 ]
Jayakaran, Prasath [2 ]
Aldabe, Daniela [1 ]
Milosavljevic, Stephan [2 ]
机构
[1] Univ Otago, Sch Phys Educ, Dunedin, New Zealand
[2] Univ Otago, Ctr Physiotherapy Res, Sch Physiotherapy, Dunedin, New Zealand
关键词
Reliability; Sacroiliac joint; Kinematics; Electromagnetic tracking device; SACROILIAC JOINTS; REPRODUCIBILITY; POSITIONS; MOVEMENTS; MOBILITY;
D O I
10.1016/j.math.2011.09.005
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Although the complex anatomical orientation and position of the sacroiliac joints (SIJ) has rendered their 3D kinematic evaluation difficult, recent techniques of palpation-digitization of pelvic landmarks using electromagnetic tracking device have been able to accurately and non-invasively quantify the subtle SIJ kinematics. While this technique demonstrates radiographic validity and high test-retest reliability, it is yet to be assessed with regards to inter-tester and trial-to-trial reliability. A single-group repeated measure design using 4 testers was conducted to evaluate the inter-tester and trial-to-trial reliability of palpation-digitization technique for innominate vector length measurements using the Polhemus electromagnetic tracking device. Fourteen young, healthy adults between the ages of 18-40 years participated in the study. The innominate vector length was calculated from 3D co-ordinates of palpated and digitized pelvic landmarks in two test positions of hip. A sensitivity analysis was conducted to determine how palpation-digitization errors for pelvic landmarks impacts on innominate angle calculation. Reliability indexes of Intraclass correlation coefficient (ICC) (>= 0.97) and Standard error of measurement (SEM) (<= 2.02 mm) demonstrated very high inter-tester and trial-to-trial reliability and accuracy of palpation-digitization technique for innominate vector length measurements, irrespective of the two test positions. A higher consistency of measurements was obtained within-testers as compared to between testers, and sensitivity analysis demonstrated a negligible influence of palpation-digitization errors on the innominate angle measurements. The results support clinical and research utility of this technique for non-invasive kinematic evaluation of SIJ motion for this population. Further research on the use of this palpation-digitization technique in symptomatic population is warranted. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 26 条
[1]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[2]   A non-invasive technique for assessing innominate bone motion [J].
Bussey, MD ;
Yanai, T ;
Milburn, P .
CLINICAL BIOMECHANICS, 2004, 19 (01) :85-90
[3]   Does the demand for asymmetric functional lower body postures in lateral sports relate to structural asymmetry of the pelvis? [J].
Bussey, Melanie D. .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2010, 13 (03) :360-364
[4]   The influence of hip abduction and external rotation on sacroiliac motion [J].
Bussey, Melanie D. ;
Bell, Melanie L. ;
Milosavljevic, Stephan .
MANUAL THERAPY, 2009, 14 (05) :520-525
[5]  
Cattley Peter, 2002, Australas Chiropr Osteopathy, V10, P73
[6]  
Domholdt E, 2005, REHABILITATION RES P, P252
[7]   Measurement of sacroiliac joint dysfunction: A multicenter intertester reliability study [J].
Freburger, JK ;
Riddle, DL .
PHYSICAL THERAPY, 1999, 79 (12) :1134-1141
[8]  
Fryer G, 2006, INT J OSTEOPATH MED, V9, P58
[9]  
Giraudeau B, 2001, STAT MED, V20, P3205, DOI 10.1002/sim.935.abs
[10]   Three-Dimensional Movements of the Sacroiliac Joint: A Systematic Review of the Literature and Assessment of Clinical Utility [J].
Goode, Adam ;
Hegedus, Eric ;
Sizer, Philip, Jr. ;
Brismee, Jean-Michel ;
Linberg, Alison ;
Cook, Chad .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2008, 16 (01) :25-38