A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

被引:52
|
作者
Tsuchimochi, M
Sakahara, H
Hayama, K
Funaki, M
Ohno, R
Shirahata, T
Orskaug, T
Maehlum, G
Yoshioka, K
Nygard, E
机构
[1] Nippon Dent Univ, Sch Dent Niigata, Dept Oral & Maxillofacial Radiol, Niigata 9518580, Japan
[2] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 43131, Japan
[3] Acrorad Co Ltd, Tokyo, Japan
[4] Integrated Detector & Elect AS, Hovik, North Ireland
关键词
CdTe; gamma camera; semiconductor; sentinel lymph node biopsy; radioguided surgery;
D O I
10.1007/s00259-003-1301-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 rum. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (Tc-99m), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM had a mean value of 1.56+/-0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating subsequent radioguided surgery.
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 33 条
  • [1] A prototype small CdTe gamma camera for radioguided surgery and other imaging applications
    Makoto Tsuchimochi
    Harumi Sakahara
    Kazuhide Hayama
    Minoru Funaki
    Ryoichi Ohno
    Takashi Shirahata
    Terje Orskaug
    Gunnar Maehlum
    Koki Yoshioka
    Einar Nygard
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1605 - 1614
  • [2] Performance of a small CdTe gamma camera for radioguided surgery
    Makoto, T
    Sakahara, H
    Hayama, K
    Funaki, M
    Shirahata, T
    Orskaug, T
    Maehlum, G
    Yoshioka, K
    Nygard, E
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 : 74 - 87
  • [3] CdTe compact gamma camera for coded aperture imaging in radioguided surgery
    Russo, Paolo
    Di Lillo, Francesca
    Corvino, Veronica
    Frallicciardi, Paola Maria
    Sarno, Antonio
    Mettivier, Giovanni
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 223 - 232
  • [4] Intraoperative gamma cameras for radioguided surgery: Technical characteristics, performance parameters, and clinical applications
    Tsuchimochi, Makoto
    Hayama, Kazuhide
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 126 - 138
  • [5] Feasibility of a beta-gamma digital imaging probe for radioguided surgery
    Tipnis, SV
    Nagarkar, VV
    Shestakova, I
    Gaysinskiy, V
    Entine, G
    Tornai, MP
    Stack, BC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 110 - 116
  • [6] Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging
    Russo, Paolo
    Curion, Assunta S.
    Mettivier, Giovanni
    Esposito, Michela
    Aurilio, Michela
    Caraco, Corradina
    Aloj, Luigi
    Lastoria, Secondo
    MEDICAL PHYSICS, 2011, 38 (03) : 1547 - 1560
  • [7] A small field of view camera for hybrid gamma and optical imaging
    Lees, J. E.
    Bugby, S. L.
    Bhatia, B. S.
    Jambi, L. K.
    Alqahtani, M. S.
    McKnight, W. R.
    Ng, A. H.
    Perkins, A. C.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [8] Small prototype gamma camera based on wavelength-shifting fibres
    Castro, I. F.
    Soares, A. J.
    Moutinho, L. M.
    Veloso, J. F. C. A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [9] Applicability of a high-resolution small semiconductor gamma camera to small animal imaging
    Kiyono, Yasushi
    Kuge, Yuji
    Katada, Yumiko
    Kawashima, Hidekazu
    Magata, Yasuhiro
    Saji, Hideo
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (09) : 736 - 741
  • [10] Radioguided surgery with combined use of gamma probe and hand-held gamma camera for treatment of papillary thyroid cancer locoregional recurrences: a preliminary study
    Bellotti, C.
    Castagnola, G.
    Tierno, S. M.
    Centanini, F.
    Sparagna, A.
    Vetrone, I.
    Mezzetti, G.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2013, 17 (24) : 3362 - 3366