Cascaded systems analysis of noise reduction algorithms in dual-energy imaging

被引:91
作者
Richard, Samuel [1 ]
Siewerdsen, Jeffrey H. [1 ,2 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[2] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
关键词
dual-energy imaging; noise reduction; flat-panel detector; imaging performance; cascaded systems analysis; DQE; MTF; NPS; NEQ; imaging task;
D O I
10.1118/1.2826556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An important aspect of dual-energy (DE) x-ray image decomposition is the incorporation of noise reduction techniques to mitigate the amplification of quantum noise. This article extends cascaded systems analysis of imaging performance to DE imaging systems incorporating linear noise reduction algorithms. A general analytical formulation of linear DE decomposition is derived, with weighted log subtraction and several previously reported noise reduction algorithms emerging as special cases. The DE image noise-power spectrum (NPS) and modulation transfer function (MTF) demonstrate that noise reduction algorithms impart significant, nontrivial effects on the spatial-frequency-dependent transfer characteristics which do not cancel out of the noise-equivalent quanta (NEQ). Theoretical predictions were validated in comparison to the measured NPS and MTF. The resulting NEQ was integrated with spatial-frequency-dependent task functions to yield the detectability index, d', for evaluation of DE imaging performance using different decomposition algorithms. For a 3 mm lung nodule detection task, the detectability index varied from d' < 1 (i.e., nodule barely visible) in the absence of noise reduction to d' > 2.5 (i.e., nodule clearly visible) for "anti-correlated noise reduction" (ACNR) or "simple-smoothing of the high-energy image" (SSH) algorithms applied to soft-tissue or bone-only decompositions, respectively. Optimal dose allocation (A*, the fraction of total dose delivered in the low-energy projection) was also found to depend on the choice of noise reduction technique. At fixed total dose, multi-function optimization suggested a significant increase in optimal dose allocation from A* = 0.32 for conventional log subtraction to A* = 0.79 for ACNR and SSH in soft-tissue and bone-only decompositions, respectively. Cascaded systems analysis extended to the general formulation of DE image decomposition provided an objective means of investigating DE imaging performance across a broad range of acquisition and decomposition algorithms in a manner that accounts for the spatial-frequency-dependent imaging task. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:586 / 601
页数:16
相关论文
共 55 条
  • [1] Linear response theory for detectors consisting of discrete arrays
    Albert, M
    Maidment, ADA
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2417 - 2434
  • [2] *AM I PHYS, 1991, 31 AAPM
  • [3] Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications
    Antonuk, LE
    Jee, KW
    El-Mohri, Y
    Maolinbay, M
    Nassif, S
    Rong, X
    Zhao, Q
    Siewerdsen, JH
    Street, RA
    Shah, KS
    [J]. MEDICAL PHYSICS, 2000, 27 (02) : 289 - 306
  • [4] Megalopinakophobia: Its symptoms and cures
    Barrett, HH
    Myers, KJ
    Gallas, B
    Clarkson, E
    Zhang, HB
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 299 - 307
  • [5] OPTIMAL RADIOGRAPHIC MAGNIFICATION FOR PORTAL IMAGING
    BISSONNETTE, JP
    JAFFRAY, DA
    FENSTER, A
    MUNRO, P
    [J]. MEDICAL PHYSICS, 1994, 21 (09) : 1435 - 1445
  • [6] STATISTICALLY DEFINED BACKGROUND - PERFORMANCE OF A MODIFIED NONPREWHITENING OBSERVER MODEL
    BURGESS, AE
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (04): : 1237 - 1242
  • [7] COMPARISON OF RECEIVER OPERATING CHARACTERISTIC AND FORCED-CHOICE OBSERVER PERFORMANCE-MEASUREMENT METHODS
    BURGESS, AE
    [J]. MEDICAL PHYSICS, 1995, 22 (05) : 643 - 655
  • [8] Human observer detection experiments with mammograms and power-law noise
    Burgess, AE
    Jacobson, FL
    Judy, PF
    [J]. MEDICAL PHYSICS, 2001, 28 (04) : 419 - 437
  • [9] Cunningham I., 2000, SPIE, P79
  • [10] Cascaded models and the DQE of flat-panel imagers: Noise aliasing, secondary quantum noise and reabsorption
    Cunningham, IA
    Yao, J
    Subotic, V
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 61 - 72