Reliability of bounce drop jump parameters within elite male rugby players

被引:12
作者
Costley, Lisa [1 ,2 ]
Wallace, Eric [1 ]
Johnston, Michael [3 ,4 ]
Kennedy, Rodney [1 ]
机构
[1] Univ Ulster, SESRI, Jordanstown, North Ireland
[2] Univ Ulster, Sports Inst Northern Ireland, Jordanstown BT37 0QB, North Ireland
[3] Loughborough Univ, British Athlet, Loughborough, Leics, England
[4] Swansea Univ, Sport & Exercise Sci Res Ctr, Swansea, W Glam, Wales
关键词
Athletic performance; Plyometric exercise; Reproducibility of results; REACTIVE STRENGTH INDEX; VERTICAL JUMP; LEG STIFFNESS; INTERSESSION RELIABILITY; FORCE VARIABLES; COUNTERMOVEMENT; PERFORMANCE; VALIDITY; FAMILIARIZATION; FATIGUE;
D O I
10.23736/S0022-4707.17.07400-X
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
BACKGROUND: The aims of the study were to investigate the number of familiarization sessions required to establish reliability of the bounce drop jump (BDJ) and subsequent reliability once familiarization is achieved. METHODS: Seventeen trained male athletes completed 4 BDJs in 4 separate testing sessions. Force-time data from a 20 cm BDJ was obtained using two force plates (ensuring ground contact <250 ms). Subjects were instructed to "jump for maximal height and minimal contact time" while the best and average of four jumps were compared. A series of performance variables were assessed in both eccentric and concentric phases including jump height, contact time. flight time, Reactive Strength Index (RSI), peak power, rate of force development (RFD) and actual dropping height (ADH). Reliability was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV) while familiarization was assessed using a repeated-measures analysis of variance (ANOVA). RESULTS: The majority of DJ parameters exhibited excellent reliability with no systematic bias evident, while the average of 4 trials provided greater reliability. With the exception of vertical stiffness (CV: 12.0%) and RFD (CV: 16.2%), all variables demonstrated low within subject variation (CV range: 3.1-8.9 6 /0). Relative reliability was very poor for ADH, with heights ranging from 14.87-29.85 cm. CONCLUSIONS: High levels of reliability can be obtained from the BDJ with the exception of vertical stiffness and RFD, however, extreme caution must be taken when comparing DJ results between individuals and squads due to large discrepancies between actual drop height and platform height.
引用
收藏
页码:1390 / 1397
页数:8
相关论文
共 45 条
[1]  
[Anonymous], PHYSIOTHERAPY PRACTI
[2]   Influence of leg stiffness and its effect on myodynamic jumping performance [J].
Arampatzis, A ;
Schade, F ;
Walsh, M ;
Brüggemann, GP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2001, 11 (05) :355-364
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]   A comparison of methods for analyzing drop jump performance [J].
Baca, A .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (03) :437-442
[5]   WHICH MEASURE OF DROP JUMP PERFORMANCE BEST PREDICTS SPRINTING SPEED? [J].
Barr, Matt J. ;
Nolte, Volker W. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (07) :1976-1982
[6]  
BOBBERT MF, 1987, MED SCI SPORT EXER, V19, P339
[7]   DROP JUMPING AS A TRAINING METHOD FOR JUMPING ABILITY [J].
BOBBERT, MF .
SPORTS MEDICINE, 1990, 9 (01) :7-22
[8]   BIOMECHANICAL ANALYSIS OF DROP AND COUNTERMOVEMENT JUMPS [J].
BOBBERT, MF ;
MACKAY, M ;
SCHINKELSHOEK, D ;
HUIJING, PA ;
SCHENAU, GJV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1986, 54 (06) :566-573
[9]  
Cohen J., 1977, Statistical Power Analysis for the Behavioral Sciences, DOI DOI 10.1016/B978-0-12-179060-8.50006-2
[10]   Reliability of Measures Obtained During Single and Repeated Countermovement Jumps [J].
Cormack, Stuart J. ;
Newton, Robert U. ;
McGuigan, Michael R. ;
Doyle, Tim L. A. .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2008, 3 (02) :131-144