NUMERICAL STUDIES ON THE EFFECT OF TIP CLEARANCE AND TIP COOLING FLOW ON ENDWALL LOSSES OF AN UNSHROUDED AXIAL TURBINE ROTOR

被引:0
作者
Ali, K. Asgar [1 ]
Nagpurwala, Quamber H. [2 ]
Nassar, Abdul [3 ]
Ramanamurthy, S. V. [4 ]
机构
[1] QuEST Global Engn Pvt Ltd, Bangalore, Karnataka, India
[2] MS Ramaiah Sch Adv Studies, Bangalore, Karnataka, India
[3] Softlnway Turbomachinery Solut Pvt Ltd, Bangalore, Karnataka, India
[4] Gas Turbine Res Estab, Bangalore, Karnataka, India
来源
PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2013 | 2014年
关键词
Turbine Losses; Tip Clearance; Tip Coolant Ejection; End Wall Flow;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper deals with the numerical investigations on a low pressure axial turbine stage to assess the effect of variation in rotor tip clearance and tip coolant ejection rate on the end wall losses. The rotor, along with the NGV; was modeled to represent the entire turbine stage. The CFX TASCflow software was used to perform steady state analysis for different rotor tip clearances and different tip coolant ejection rates. The locations of the cooling slots were identified on the blade tip and the coolant ejection rate was specified at these areas. The simulations were carried out with tip clearances of 0%, 1% and 2% of blade height and ejection flow rates of 0.5%, 0.75% and 1% of main turbine flow rate. It is shown that the size and strength of the leakage vortex is directly related to the tip clearance. The reduction in efficiency is not in linearity with the tip clearance owing to the effect of boundary layer growth on the end walls. Introduction of the tip coolant flow shows increased total total efficiency compared to that of the uncooled tip. This is attributed to a reduction in the strength of the leakage vortex due to reduced cross-flow over the tip clearance from pressure surface to suction surface. At a coolant flow rate of 0.75% of the main flow rate, there is significant increase in efficiency of about 0.5%. Optimum tip clearance and coolant flow rate are obtained based on the results of the present analysis.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effect of tip clearance on cavitating flow of a hydraulic axial turbine applied in turbopump
    Whitacker, Luiz Henrique Lindquist
    Tomita, Jesuino Takachi
    Bringhenti, Cleverson
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2022, 213
  • [2] Flow Visualization and Topological Analysis of a Turbine Rotor Cascade with Tip Clearance
    Han Wanjin
    Liu Fengjun
    Zhong Jingjun
    Wang Zhongqi (Department of Power Engineering
    JournalofThermalScience, 1997, (03) : 164 - 170
  • [3] Flow visualization and topological analysis of a turbine rotor cascade with tip clearance
    Han W.
    Liu F.
    Zhong J.
    Wang Z.
    Journal of Thermal Science, 1997, 6 (3) : 164 - 170
  • [4] Experimental study of endwall and tip clearance flows in a two - Dimensional turbine rotor blade cascade - Effect of incidence angle
    Govardhan M.
    Gowda B.H.L.
    Wankhade R.M.
    Journal of Thermal Science, 2000, 9 (1) : 63 - 76
  • [5] NUMERICAL INVESTIGATION OF LEAKAGE FLOW IN AXIAL FLOW TURBINES: EFFECT OF TIP CLEARANCE AND RELATIVE MOTION
    Maral, Hidir
    Senel, Cem Berk
    Kavurmacioglu, Levent Ali
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 37 (01) : 79 - 92
  • [6] Effect of tip clearance, winglets, and shroud height on the tip leakage in axial flow fans
    Jung, Jae Hyuk
    Joo, Won-Gu
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 93 : 195 - 204
  • [7] Experimental Study of Endwall and Tip Clearance Flows in a Two- Dimensional Turbine Rotor Blade Cascade - Effect of Incidence Angle
    M. Govardhan
    B.H.L. Gowda
    R.M. Wankhade
    Journal of Thermal Science, 2000, (01) : 63 - 76
  • [8] Numerical Simulation on Axial Flow Fan Performance with Changing Tip Clearance
    Ye, Zhou
    Zhao, Haiyang
    Zhang, Lu
    Li, Chun
    Gao, Wei
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 577 - 580
  • [9] THE EFFECT OF TIP CLEARANCE ON THE PERFORMANCE OF AN AXIAL-FLOW FAN
    VENTER, SJ
    KROGER, DG
    ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (02) : 89 - 97
  • [10] Effect of tip clearance and rotor-stator axial gap on the efficiency of a multistage compressor
    Danish, Syed Noman
    Qureshi, Shafiq Rehman
    Imran, Malik Muhammad
    Khan, Salah Ud-Din
    Sarfraz, Muhammad Mansoor
    El-Leathy, Abdelrahman
    Al-Ansary, Hany
    Wei, Mingshan
    APPLIED THERMAL ENGINEERING, 2016, 99 : 988 - 995