摘要
The corrosion resistance of the new Ti-6Al-4V-1Zr alloy in comparison with ternary Ti-6Al-4V alloy in Ringer-Brown solution and artificial Carter-Brugirard saliva of different pH values was studied. In Ringer-Brown solution, the new alloy presented an improvement of all electrochemical parameters due to the alloying with Zr; also, impedance spectra revealed better protective properties of its passive layer. In Carter-Brugirard artificial saliva, an increase of the passive film thickness was proved. Fluoride ions had a slight negative influence on the corrosion and ion release rates, without to affect the very good stability of the new Ti-6Al-4V-1Zr alloy.
引用
收藏
页码:1892 / 1896
页数:5
相关论文
共 35 条
[11]  
Kulakov O B, 2005, Morfologiia, V127, P52
[12]   Surface characteristics and corrosion behavior of Ti-Al-Zr alloy implanted with Al and Nb [J].
Liu, Y. Z. ;
Zu, X. T. ;
Li, C. ;
Qiu, S. Y. ;
Huang, X. Q. ;
Wang, L. M. .
CORROSION SCIENCE, 2007, 49 (03) :1069-1080
[13]  
Manhabosco TM, 2009, QUIM NOVA, V32, P2263, DOI 10.1590/S0100-40422009000900004
[14]  
Mareci D, 2008, REV CHIM-BUCHAREST, V59, P999
[15]   Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy [J].
Milosev, I ;
Metikos-Hukovic, M ;
Strehblow, HH .
BIOMATERIALS, 2000, 21 (20) :2103-2113
[16]   Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads [J].
Milosev, L ;
Antolic, V ;
Minovic, A ;
Cör, A ;
Herman, S ;
Pavlovcic, V ;
Campbell, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03) :352-357
[17]   Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V [J].
Okazaki, Y ;
Rao, S ;
Ito, Y ;
Tateishi, T .
BIOMATERIALS, 1998, 19 (13) :1197-1215
[18]   Surface analysis of Ti-15Zr-4Nb-4Ta alloy after implantation in rat tibia [J].
Okazaki, Y ;
Nishimura, E ;
Nakada, H ;
Kobayashi, K .
BIOMATERIALS, 2001, 22 (06) :599-607
[19]  
Oliveira NTC, 2002, J BRAZIL CHEM SOC, V13, P463, DOI 10.1590/S0103-50532002000400009
[20]   In situ characterization of passive films on Al-Ti alloy by photocurrent and impedance spectroscopy [J].
Piazza, S ;
Lo Biundo, G ;
Romano, MC ;
Sunseri, C ;
Di Quarto, F .
CORROSION SCIENCE, 1998, 40 (07) :1087-1108