CORROSION RESISTANCE IMPROVEMENT OF TITANIUM BASE ALLOYS

被引:25
作者
Popa, Mihai V. [1 ]
Vasilescu, Ecaterina [1 ]
Drob, Paula [1 ]
Vasilescu, Cora [1 ]
Drob, Silviu I. [1 ]
Mareci, Daniel [2 ]
Mirza Rosca, Julia C. [3 ]
机构
[1] Inst Phys Chem Ilie Murgulescu, Bucharest 060021, Romania
[2] Tech Univ Gh Asachi, Iasi 700050, Romania
[3] Las Palmas de Gran Canaria Univ, Dept Mech Engn, Tafira 35017, Spain
来源
QUIMICA NOVA | 2010年 / 33卷 / 09期
关键词
corrosion rates; EIS; Ti6Al4V1Zr alloy; IMPLANT MATERIALS; DENTAL ALLOYS; ZIRCONIUM; INTERFACE; STABILITY; BIOFLUIDS; BEHAVIOR; TI-13NB-13ZR; TI-6AL-4V; NB;
D O I
10.1590/S0100-40422010000900014
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The corrosion resistance of the new Ti-6Al-4V-1Zr alloy in comparison with ternary Ti-6Al-4V alloy in Ringer-Brown solution and artificial Carter-Brugirard saliva of different pH values was studied. In Ringer-Brown solution, the new alloy presented an improvement of all electrochemical parameters due to the alloying with Zr; also, impedance spectra revealed better protective properties of its passive layer. In Carter-Brugirard artificial saliva, an increase of the passive film thickness was proved. Fluoride ions had a slight negative influence on the corrosion and ion release rates, without to affect the very good stability of the new Ti-6Al-4V-1Zr alloy.
引用
收藏
页码:1892 / 1896
页数:5
相关论文
共 35 条
[1]  
ALMEIDA D, 2007, QUIM NOVA, V30, P1129
[2]  
ARAUJO JC, 2007, QUIM NOVA, V30, P1853
[3]   Electrochemical evaluation of Ti-13Nb-13Zr, Ti-6Al-4V and Ti-6Al-7Nb alloys for biomedical application by long-term immersion tests [J].
Assis, S. L. ;
Costa, I. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2007, 58 (05) :329-333
[4]  
Black J., 1999, BIOLOGICAL PERFORMAN, V3rd
[5]   Corrosion behaviour of porous titanium-graphite composites designed for surgical implants [J].
Blackwood, DJ ;
Chua, AWC ;
Seah, KHW ;
Thampuran, R ;
Teoh, SH .
CORROSION SCIENCE, 2000, 42 (03) :481-503
[6]  
Cabrini R L, 1993, Implant Dent, V2, P264
[7]   WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[8]   Porous titanium production and porosity control by powder metallurgy (P/M) [J].
de Almeida Braga, Neila ;
Ferreira, Neidenei Gomes ;
Alves Cairo, Carlos Alberto .
QUIMICA NOVA, 2007, 30 (02) :450-457
[9]   Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy [J].
Geetha, M ;
Mudali, UK ;
Gogia, AK ;
Asokamani, R ;
Raj, B .
CORROSION SCIENCE, 2004, 46 (04) :877-892
[10]  
Guglielmotti M B, 1997, Acta Odontol Latinoam, V10, P11