Hyperintensity in the subarachnoid space on FLAIR MRI

被引:90
作者
Stuckey, Stephen L.
Goh, Tony D.
Heffernan, Theresa
Rowan, David
机构
[1] Princess Alexandra Hosp, Dept Radiol, Woolloongabba, Qld 4102, Australia
[2] Christchurch Hosp, Dept Radiol, Christchurch, New Zealand
[3] Wesley Hosp, Dept Radiol, Auchenflower, Qld, Australia
[4] Alfred Hosp, Dept Radiol, Prahran, Vic 3181, Australia
关键词
brain; CSF; FLAIR; MRI; subarachnoid space;
D O I
10.2214/AJR.07.2424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purposes of this essay are to illustrate the causes of FLAIR hyperintensity in the subarachnoid space and to outline the mechanisms of the findings. CONCLUSION. FLAIR subarachnoid space hyperintensity may be encountered with both pathological conditions and artifacts. Knowledge of these conditions and appearances coupled with any associated findings may suggest the cause of the FLAIR subarachnoid space hyperintensity. A diffuse distribution and a lack of ancillary findings often remain nonspecific and may require clinical correlation and CSF analysis.
引用
收藏
页码:913 / 921
页数:9
相关论文
共 38 条
[1]  
Anzai Y, 2004, AM J NEURORADIOL, V25, P274
[2]   MR IMAGING IS HIGHLY SENSITIVE FOR ACUTE SUBARACHNOID HEMORRHAGE - NOT [J].
ATLAS, SW .
RADIOLOGY, 1993, 186 (02) :319-322
[3]  
Bakshi R, 1999, AM J NEURORADIOL, V20, P629
[4]   Cerebrospinal fluid changes after intravenous injection of gadolinium chelate: assessment by FLAIR MR imaging [J].
Bozzao, A ;
Floris, R ;
Fasoli, F ;
Fantozzi, LM ;
Colonnese, C ;
Simonetti, G .
EUROPEAN RADIOLOGY, 2003, 13 (03) :592-597
[5]  
Braga FT, 2003, AM J NEURORADIOL, V24, P1863
[6]   Cerebrospinal fluid signal intensity increase on FLAIR MR images in patients under general anesthesia:: The role of supplemental O2 [J].
Deliganis, AV ;
Fisher, DJ ;
Lam, AM ;
Maravilla, KR .
RADIOLOGY, 2001, 218 (01) :152-156
[7]  
Ercan N, 2004, AM J NEURORADIOL, V25, P761
[8]   Supplemental oxygen causes increased signal intensity in subarachnoid cerebrospinal fluid on brain FLAIR MR images obtained in children during general anesthesia [J].
Frigon, C ;
Shaw, DWW ;
Heckbert, SR ;
Weinberger, E ;
Jardine, DS .
RADIOLOGY, 2004, 233 (01) :51-55
[9]   Post-contrast FLAIR MR imaging of the brain in children: normal and abnormal intracranial enhancement [J].
Goo, HW ;
Choi, CG .
PEDIATRIC RADIOLOGY, 2003, 33 (12) :843-849
[10]   USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844