Optimized Fresh and Hardened Properties of Strain Hardening Cementitious Composites: Effect of Mineral Admixtures, Cementitious Composition, Size, and Type of Aggregates

被引:25
作者
Khan, M. Iqbal [1 ,2 ]
Fares, Galal [3 ]
Mourad, Shehab [4 ]
机构
[1] King Saud Univ, Coll Engn, Ctr Excellence Concrete Res & Testing, Struct Engn, POB 800, Riyadh 11421, Saudi Arabia
[2] King Saud Univ, Coll Engn, Ctr Excellence Concrete Res & Testing, Dept Civil Engn, POB 800, Riyadh 11421, Saudi Arabia
[3] King Saud Univ, Coll Engn, Ctr Excellence Concrete Res & Testing, POB 800, Riyadh 11421, Saudi Arabia
[4] King Saud Univ, Coll Engn, Dept Civil Engn, Struct Engn, POB 800, Riyadh 11421, Saudi Arabia
关键词
Aggregate size; Engineered cementitious composites; Fly ash and slag-based cementitious system; Ductility; Water sorptivity; BLAST-FURNACE SLAG; MECHANICAL-PROPERTIES; REINFORCED-CONCRETE; HIGH VOLUMES; FLY-ASH; PERFORMANCE; DUCTILITY; BEHAVIOR;
D O I
10.1061/(ASCE)MT.1943-5533.0002039
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present paper thoroughly investigates the effects of mix design with various water-to-binder (W/B) ratios, types of mineral admixture and types and sizes of local sands on the tensile ductility of engineered cementitious composites (ECC). White and red dune sands-denoted W and D, whereas their sieved forms are denoted SW and SD, respectively-were collected from the Arabian Desert, the second largest on the earth. Fly ash (FA) and ground granulated blast furnace slag (GGBFS) were separately used as mineral admixtures in the production of ECC. The development of ductility in ECC mixtures incorporating FA was found to reduce with curing time, whereas it was found to increase with GGBFS. An ECC mixture containing 62% GGBFS with W/B ratio of 0.35 has delivered the best fresh and hardened properties with strain capacity of 4.2% and tensile strength of 5.2 MPa at 28 days. Water sorptivity of fully cracked dune sand-based ECC mixtures was lower than that given by normal concrete. It is concluded that dune sand-based ECC mixtures have provided comparable results to the reference silica sand-based ECC mixtures. (C) 2017 American Society of Civil Engineers.
引用
收藏
页数:16
相关论文
共 38 条
[1]  
[Anonymous], 2006, P INT RILEM WORKSH H
[2]  
[Anonymous], 2015, C61815 ASTM
[3]  
ASTM, 2017, C150/C150M-17, standard specification for Portland cement, Am. Soc. Test. Mater.
[4]  
ASTM, 2016, C989C989M16E1 ASTM
[5]  
ASTM C1585-04/C1585-13, 2004, Standard test method for measurement of rate of absorption of water by hydraulic cement concretes, DOI [DOI 10.1520/C1585-13, DOI 10.1520/C1585-13.2]
[6]  
BANTHIA N, 1995, ACI MATER J, V92, P48
[7]  
BUYUKOZTURK O, 2002, P 7 US NAT C EARTHQ
[8]   The hydration of slag, part 1: reaction models for alkali-activated slag [J].
Chen, W. ;
Brouwers, H. J. H. .
JOURNAL OF MATERIALS SCIENCE, 2007, 42 (02) :428-443
[9]   Activation of fly ash and its effects on cement properties [J].
Fan, YM ;
Yin, SH ;
Wen, ZY ;
Zhong, JY .
CEMENT AND CONCRETE RESEARCH, 1999, 29 (04) :467-472
[10]  
Kanda T., 1999, J ENG MECH, DOI [10.1061/(ASCE)0733-9399(1999)125, DOI 10.1061/(ASCE)0733-9399(1999)125]