Effects of evaporator frosting on the performance of an air-to-air heat pump

被引:12
|
作者
Martínez-Frías, J [1 ]
Aceves, SM [1 ]
机构
[1] Ctr Ingn & Desarrollo Ind, Queretaro, Mexico
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 1999年 / 121卷 / 01期
关键词
D O I
10.1115/1.2795061
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper shows the development and use of a transient model for evaluating frost formation on a parallel-plate hear pump evaporator. A frost formation model is derived by applying the equations of conservation of mass, momentum, and energy, as well as empirical correlations, to calculate the growth and densification of the frost layer. The frost formation model is validated by comparison with experimental results. The frost formation model is then incorporated into the evaporator subroutine of an existing heat primp model to calculate performance losses due to frosting as a function of weather conditions and time of operation since the last evaporator defrost. Performance loss calculation includes the effect of air pressure drop through the evaporator and the reduction in evaporator temperature caused by the growth of the frost layer. The results show frost formation parameters and heat pump COP as a function of time and ambient conditions. It is determined that there is a range of ambient temperatures and humidities in which frosting effects are most severe, and this range is explored to calculate heat pump operating conditions. The heat pump analysis results are expected to be useful in predicting optimum defrosting conditions, and to evaluate alternative methods for defrosting.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 50 条
  • [1] PERFORMANCE OF AN AIR-TO-AIR HEAT-PUMP UNDER FROSTING AND DEFROSTING CONDITIONS
    KAYGUSUZ, K
    APPLIED ENERGY, 1994, 48 (03) : 225 - 241
  • [2] INFLUENCE OF EVAPORATOR FROSTING ON THE PERFORMANCE OF AN OUTDOOR AIR WATER HEAT-PUMP
    DANJOUX, R
    EGEE, M
    BAILLY, A
    POPLIMONT, P
    REVUE GENERALE DE THERMIQUE, 1986, 25 (293): : 289 - 296
  • [3] Performance evaluation of a compact air-to-air heat pump
    Kent, EF
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (04) : 341 - 345
  • [4] FACTORS AFFECTING PERFORMANCE OF A RESIDENTIAL AIR-TO-AIR HEAT PUMP
    PARKEN, WH
    BEAUSOLIEL, RW
    KELLY, GE
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 43 - 44
  • [5] EFFECTS OF EVAPORATOR FROSTING AND DEFROSTING ON THE PERFORMANCE OF AIR-TO-WATER HEAT-PUMPS
    TASSOU, SA
    MARQUAND, CJ
    APPLIED ENERGY, 1987, 28 (01) : 19 - 33
  • [6] EFFECTS OF EVAPORATOR FROSTING AND DEFROSTING ON THE PERFORMANCE OF AIR-TO-WATER HEAT PUMPS.
    Tassou, S.A.
    Marquand, C.J.
    Applied energy, 1987, 28 (0l) : 9 - 33
  • [7] A POLYMERIC APPROACH TO COUNTERACT FROSTING IN AIR-TO-AIR HEAT-EXCHANGERS
    OSTIN, R
    JOHANNESSON, G
    HEAT RECOVERY SYSTEMS & CHP, 1991, 11 (05): : 415 - 421
  • [8] Effects of the fraction of evaporator bypass air on heat pump dryer performance
    Achariyaviriya, Siva
    Chotswasd, Methawut
    FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT ASME/JSME FLUIDS ENGINEERING SUMMER CONFERENCE, VOL 2, PTS A AND B, 2007, : 1305 - 1313
  • [9] A review of frosting in air-to-air energy exchangers
    Rafati Nasr, M. (mh.rafati@usask.ca), 1600, Elsevier Ltd (30):
  • [10] A review of frosting in air-to-air energy exchangers
    Nasr, Mohammad Rafati
    Fauchoux, Melanie
    Besant, Robert W.
    Simonson, Carey J.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 30 : 538 - 554