Wall thinning in carbon steel pipeline carrying pure water at high temperature

被引:9
|
作者
Matsumura, M.
机构
[1] 237-101 Fukumoto, Saijo, Higashi-Hiroshima
来源
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION | 2015年 / 66卷 / 07期
关键词
boiler; elbow; flow accelerated corrosion; localized corrosion; macro-cell corrosion; water-line corrosion;
D O I
10.1002/maco.201407650
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the boilers of thermal and nuclear power plants, neutral pure water with low electric conductivity is generally used after de-oxygenation, which is utilized to suppress the corrosiveness of the water. Nevertheless, a relatively high rate of wall thinning occurs on the inside surface of carbon steel pipes, in particular the downstream orifice meters and T-junctions, sometimes leading to the rupture of the pipe. The generation of wall thinning has been attributed to FAC (flow accelerated corrosion), implying that the water flow must raise the corrosiveness of the boiler water. Contrary to this explanation, the macro-cell corrosion theory, which was proposed by this author, regards this occurrence as merely localized corrosion. Under such circumstances, a case study was conducted on a burst carbon steel pipe from a high pressure steam line, and the cause was substantially proven to be water-line corrosion. Because water-line corrosion is a localized corrosion that can occur without water flow, the wall thinning damage that occurred in the carbon steel pipes must have been brought about by localized corrosion and not FAC.
引用
收藏
页码:688 / 694
页数:7
相关论文
共 50 条
  • [1] A case study of unusual corrosion damage in a carbon steel pipe wall carrying pure water at elevated temperatures
    Hiroshima University, Saijo, Fukumoto 237-101, Higashi-Hiroshima, 739-0031, Japan
    Zairyo Kankyo, 2007, 8 (362-366):
  • [2] Corrosion of carbon steel in flowing pure water under high temperature and high pressure conditions
    Tachibana, Shinya
    Yabuki, Akihiro
    Matsumura, Masanobu
    Marugame, Kazuo
    2000, Japan Soc of Corrosion Engineering, Tokyo, Japan (49):
  • [3] The safety evaluation and life prediction for local wall thinning elbows of high temperature steam pipeline
    He, Xiaohua
    Zhou, Changyu
    EVALUATION, INSPECTION AND MONITORING OF STRUCTURAL INTEGRITY, 2008, : 323 - 326
  • [4] LOW-CYCLE FATIGUE OF CARBON-STEEL IN HIGH-TEMPERATURE PURE WATER ENVIRONMENT
    HIGUCHI, M
    SAKAMOTO, H
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 (08): : 1025 - 1031
  • [5] Erosion/corrosion of carbon steel in high temperature water
    Shibata, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 2005, 47 (01): : 30 - 34
  • [6] Fracture and general yield for carbon steel pipes with local wall thinning
    Miyazaki, K
    Kanno, S
    Ishiwata, M
    Hasegawa, K
    Ahn, SH
    Ando, K
    NUCLEAR ENGINEERING AND DESIGN, 2002, 211 (01) : 61 - 68
  • [7] Wall thinning analysis of carbon steel pipes in nuclear power plants
    Ma, Na
    Yin, Chang-Geng
    Qin, Jin-Guang
    Hedongli Gongcheng/Nuclear Power Engineering, 2013, 34 (02): : 123 - 125
  • [8] Nonlinear magnetic method for estimation of wall thinning in carbon steel pipe
    Park, Il Han
    Chai, Jangbom
    Kim, Young Sun
    Baek, Myung Ki
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2011, 37 (2-3) : 189 - 198
  • [9] Effect of length of thinning area on the failure behavior of carbon steel pipe containing a defect of wall thinning
    Kim, JW
    Park, CY
    NUCLEAR ENGINEERING AND DESIGN, 2003, 220 (03) : 274 - 284
  • [10] Fundamental study on corrosion of carbon steel in high temperature water
    Isomoto Y.
    Sato T.
    Zairyo to Kankyo/ Corrosion Engineering, 2010, 59 (07): : 265 - 271