Numerical study of conduction and convection heat losses from a half-insulated air-filled annulus of the receiver of a parabolic trough collector

被引:75
作者
Al-Ansary, Hany [1 ]
Zeitoun, O. [1 ]
机构
[1] King Saud Univ, Dept Mech Engn, Riyadh 11421, Saudi Arabia
关键词
Parabolic trough collectors; Air-filled annulus; Natural convection; Heat loss; Concentrated solar power; Computational fluid dynamics; NATURAL-CONVECTION;
D O I
10.1016/j.solener.2011.09.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Grid-quality parabolic trough collectors utilize expensive receivers that maintain vacuum in their annuli to reduce convection losses. On the other hand, receivers with air-filled annuli, currently used mainly for process heat applications, are significantly less expensive, but their thermal performance is inferior to evacuated receivers. A promising technique that can bridge the cost and performance gap between the two types of receivers is introduced in this work. A heat-resistant thermal insulation material is fitted into the portion of the receiver annulus that does not receive concentrated sunlight. The presence of this insulation material is expected to reduce not only convection heat losses, but also radiation losses. This study focuses on the calculation of conduction and convection heat losses from the proposed receiver using numerical modeling. The performance of the proposed concept is compared to that of a conventional receiver with an air-filled annulus. The results have shown that the combined conduction and convection heat loss from the proposed receiver can be smaller than that from a receiver with an air-filled annulus by as much as 25% when fiberglass insulation is used. However, the fact that the thermal conductivity of the insulating material increases with temperature reduces the benefit of the proposed concept at high temperatures. As a result, the proposed receiver is expected to be suitable as a replacement for receivers with air-filled annuli or as an economical alternative to evacuated receivers that are used at the lower temperature end of utility-scale solar power plants. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3036 / 3045
页数:10
相关论文
共 25 条
[1]  
Al-Ansary H., 2010, US Patent Application, Patent No. [12/718,960, 12718960]
[2]  
ALSHAHRANI D, 2006, INT J HEAT TECHNOLOG, V24
[3]  
Alshahrani D, 2005, ALEXANDRIA ENG J, V44, P813
[4]  
[Anonymous], 1998, 7 AIAA ASME JOINT TH
[5]   NATURAL CONVECTIVE OSCILLATORY FLOW IN CYLINDRICAL ANNULI [J].
BISHOP, EH ;
CARLEY, CT ;
POWE, RE .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1968, 11 (12) :1741-&
[6]  
Burkholder F., 2009, HEAT LOSS TESTING SC
[7]   NATURAL CONVECTION IN HORIZONTAL CONCENTRIC CYLINDRICAL ANNULI [J].
CRAWFORD, L ;
LEMLICH, R .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1962, 1 (04) :260-&
[8]  
Dudley V., 1978, SAND0780624 SAND NAT
[9]  
EISherbiny S. M., 2004, ALEX ENG J, V43, P297
[10]   LAMINAR AND TURBULENT NATURAL-CONVECTION IN THE ANNULUS BETWEEN HORIZONTAL CONCENTRIC CYLINDERS [J].
FAROUK, B ;
GUCERI, SI .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (04) :631-636