Technical Note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks

被引:92
作者
Fayad, Hadi [1 ]
Pan, Tinsu [2 ]
Clement, Jean Francois [1 ]
Visvikis, Dimitris [1 ]
机构
[1] CHU Morvan, LaTIM, INSERM, U650, F-29200 Brest, France
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
respiratory motion; patient external surface; 4D CT; TUMOR MOTION; TRACKING SYSTEM; IMAGING-SYSTEM; LOCALIZATION; RADIOTHERAPY; ACCURACY; POSITION; THERAPY; SENSOR;
D O I
10.1118/1.3589131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the entire patient external surface in real time. The main objective of this study was to assess the motion correlation between such an external patient surface and internal anatomical landmarks motion. Methods: Four dimensional computed tomography (4D CT) volumes for ten patients were used in this study. Anatomical landmarks were manually selected in the thoracic region across the 4D CT datasets by two experts. The landmarks included normal structures as well as the tumor location. In addition, a distance map representing the entire external patient surface, which corresponds to surfaces acquired by a time of flight (ToF) camera or similar devices, was created by segmenting the skin of all 4D CT volumes using a thresholding algorithm. Finally, the correlation between the internal landmarks and external surface motion was evaluated for different regions (placement and size) throughout a patient's surface. Results: Significant variability was observed in the motion of the different parts of the external patient surface. The larger motion magnitude was consistently measured in the central regions of the abdominal and the thoracic areas for the different patient datasets considered. The highest correlation coefficients were observed between the motion of these external surface areas and internal landmarks such as the diaphragm and mediastinum structures as well as the tumor location landmarks (0.8 +/- 0.18 and 0.72 +/- 0.12 for the abdominal and the thoracic regions, respectively). Worse correlation was observed when one considered landmarks not significantly influenced by respiratory motion such as the apex and the sternum. Conclusions: There were large differences in the motion correlation observed considering different regions of interest placed over a patients' external surface and internal anatomical landmarks. The positioning of current devices used for respiratory motion synchronization may reduce such correlation by averaging the motion over correlated and poorly correlated external regions. The potential of capturing in real-time the motion of the complete external patient surface as well as choosing the area of the surface that correlates best with the internal motion should allow reducing such variability and associated errors in both respiratory motion synchronization and subsequent motion modeling processes. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3589131]
引用
收藏
页码:3157 / 3164
页数:8
相关论文
共 31 条
[1]   Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT [J].
Beddar, A. Sam ;
Kainz, Kristofer ;
Briere, Tina Marie ;
Tsunashima, Yoshikazu ;
Pan, Tinsu ;
Prado, Karl ;
Mohan, Radhe ;
Gillin, Michael ;
Krishnan, Sunil .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02) :630-638
[2]   A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup [J].
Bert, C ;
Metheany, KG ;
Doppke, K ;
Chen, GTY .
MEDICAL PHYSICS, 2005, 32 (09) :2753-2762
[3]  
Clement JF, 2009, J NUCL MED, V50
[4]   A Patient Specific Respiratory Model Based on 4D CT Data and a Time of Flight Camera (TOF) [J].
Fayad, H. ;
Pan, T. ;
Roux, C. ;
Le Rest, C. Cheze ;
Pradier, O. ;
Clement, J. F. ;
Visvikis, D. .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :2594-+
[5]  
Fayad H., IEEE ISBI C P BOST M, P1319
[6]   The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating [J].
Gierga, DP ;
Brewer, J ;
Sharp, GC ;
Betke, M ;
Willett, CG ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1551-1558
[7]  
Giraud P, 2003, Cancer Radiother, V7 Suppl 1, p15s
[8]   Internal-external correlation investigations of respiratory induced motion of lung tumors [J].
Ionascu, Dan ;
Jiang, Steve B. ;
Nishioka, Seiko ;
Shirato, Hiroki ;
Berbeco, Ross I. .
MEDICAL PHYSICS, 2007, 34 (10) :3893-3903
[9]   Derivation of the tumor position from external respiratory surrogates with periodical updating of the internal/external correlation [J].
Kanoulas, E. ;
Aslam, J. A. ;
Sharp, G. C. ;
Berbeco, R. I. ;
Nishioka, S. ;
Shirato, H. ;
Jiang, S. B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17) :5443-5456
[10]   The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J].
Keall, Paul J. ;
Mageras, Gig S. ;
Balter, James M. ;
Emery, Richard S. ;
Forster, Kenneth M. ;
Jiang, Steve B. ;
Kapatoes, Jeffrey M. ;
Low, Daniel A. ;
Murphy, Martin J. ;
Murray, Brad R. ;
Ramsey, Chester R. ;
Van Herk, Marcel B. ;
Vedam, S. Sastry ;
Wong, John W. ;
Yorke, Ellen .
MEDICAL PHYSICS, 2006, 33 (10) :3874-3900