Cementing a polyethylene liner into a well-fixed acetabular shell during revision hip arthroplasty may be appropriate in select patients. The purpose of this Study was to review Our early results with this technique. Sixteen patients with >2-year follow-up or who had any complications at <2 years from surgery were identified. Indications for this technique included: failure of the previous locking mechanism, significant polyethylene wear, malposition of the well-fixed metal shell, and previous removal of the liner with a retained acetabular shell. One acetabular shell has been revised at 13 months for multiple dislocations. Hip scores improved an average of 24.2 points. Radiographs revealed no polyethylene dissociation or acetabular loosening. Complications occurred in 7 patients. Initial results appear successful at providing secure fixation, while preventing the bone loss that might occur with removal of a well-fixed component. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 19 条
[1]   COMPLICATIONS RELATED TO MODULARITY OF TOTAL HIP COMPONENTS [J].
BARRACK, RL ;
BURKE, DW ;
COOK, SD ;
SKINNER, HB ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :688-692
[2]   Mechanical stability of polyethylene liners cemented into acetabular shells [J].
Bensen, CV ;
Del Schutte, H ;
Weaver, KD .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2000, 28 (1-2) :7-10
[3]   Well-fixed acetabular component retention or replacement - The whys and the wherefores [J].
Blaha, JD .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :157-161
[4]  
BOBYN JD, 1994, CLIN ORTHOP RELAT R, V298, P27
[5]   Survival analysis of the Harris-Galante I acetabular cup [J].
Böhm, P ;
Bösche, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :396-403
[6]   Cementation of a polyethylene liner into a metal shell - Factors related to mechanical stability [J].
Bonner, KF ;
Delanois, RE ;
Harbach, G ;
Bushelow, M ;
Mont, MA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (09) :1587-1593
[7]  
CHMELL MJ, 1995, CLIN ORTHOP RELAT R, P77
[8]  
FEHRING TK, 1999, CLIN ORTHOP RELAT R, V367, P306
[9]   Polyethylene liner cementation into fixed acetabular shells [J].
Haft, GF ;
Heiner, AD ;
Callaghan, JJ ;
Dorr, LD ;
Wan, ZN ;
Long, W ;
Longjohn, DB ;
Brown, TD .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :167-170
[10]  
Harris W H, 1971, Clin Orthop Relat Res, V81, P105, DOI 10.1097/00003086-197111000-00016