Spot Check Analysis of Gas Exchange: Invasive versus Noninvasive Methods

被引:20
作者
Ekkernkamp, Emelie [1 ]
Welte, Lena [1 ]
Schmoor, Claudia [2 ]
Huttmann, Sophie Emilia [3 ]
Dreher, Michael [4 ]
Windisch, Wolfram [3 ]
Storre, Jan Hendrik [1 ,3 ]
机构
[1] Univ Hosp, Dept Pneumol, Freiburg, Germany
[2] Univ Med Ctr, Clin Trials Unit, Freiburg, Germany
[3] Univ Witten Herdecke, Kliniken Stadt Koln gGmbH, Cologne Merheim Hosp, Fac Med,Sch Med,Dept Pneumol, DE-51109 Cologne, Germany
[4] Univ Hosp, Dept Cardiol Pneumol Angiol & Intens Care, Aachen, Germany
关键词
Blood gas analysis; Respiratory failure; Transcutaneous; blood gas measurement; CARBON-DIOXIDE; BLOOD-GASES; TRANSCUTANEOUS OXYGEN; CAPILLARY BLOOD; ARTERIAL; PCO2; VENTILATION; ELECTRODE; THERAPY; TENSION;
D O I
10.1159/000371769
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Correct measurement of PO2 and PCO2 is essential to establish appropriate therapy such as long-term oxygen therapy (LTOT) in patients suffering from respiratory failure. Objectives: We aimed to compare common invasive and noninvasive methods for assessing blood gas components for spot check analysis. Methods: Arterial (PaO2, PaCO2) and capillary blood gas (PCBGO2, PCBGCO2) measurements were taken consecutively in a randomized order and were compared with noninvasive measurements obtained from the transcutaneous monitoring of PO2 and PCO2 (PtcO2, PtcC2, sensor-temperature 44 degrees C). Capillary samples were taken from both arterialized earlobes, where samples of right earlobes were defined as a reference value. Pain assessment of all measurements was evaluated by each subject using the 100-mm visual analogue scale. Results: 83 patients and 17 healthy subjects were included. The mean difference between PaO2 and PtcO2 was 11.9 +/- 15.0 mm Hg, with lower limits of agreement (LLA) of -17.4 mm Hg (95% confidence interval (CI) -22.5 to -12.3 mm Hg), and upper limits of agreement (ULA) of 41.1 mm Hg (95% CI 36.0-46.2 mm Hg). The comparison of PaO2 with PCBGO2 showed a mean difference of 5.6 +/- 7.2 mm Hg (LLA -11.0; ULA 19.6 mm Hg). The mean difference between PaCO2 and PtcCO2 was 1.1 +/- 4.9 mm Hg (LLA -8.6; ULA 10.8 mm Hg) and that between PaCO2 and PCBGCO2 was 0.7 +/- 2.0 mm Hg (LLA -3.3; ULA 4.8 mm Hg). The analysis of capillary blood gases (36.2 +/- 22.3 mm) was rated as more painful than the analysis of arterial blood gases (26.1 +/- 20.6 mm), while transcutaneous measurement was rated as the least painful method (1.9 +/- 7.4 mm; all p < 0.0001). Conclusions: The comparison of different methods for blood gas measurements showed substantial differences between capillary and arterial PO2 and between transcutaneous and arterial PO2. Therefore, arterial PO2 analysis is the essential method evaluating indication for LTOT. Nevertheless, comparative analysis further indicated capillary PCO2 as an adequate surrogate for arterial PCO2. (C) 2015 S. Karger AG, Basel
引用
收藏
页码:294 / 303
页数:10
相关论文
共 29 条
[1]   Transcutaneous Pco2 monitoring in critically ill adults:: Clinical evaluation of a new sensor [J].
Bendjelid, K ;
Schütz, N ;
Stotz, M ;
Gerard, I ;
Suter, PM ;
Romand, JA .
CRITICAL CARE MEDICINE, 2005, 33 (10) :2203-2206
[2]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[3]  
Cox Paul, 2007, J Minim Access Surg, V3, P8, DOI 10.4103/0972-9941.30680
[4]   Limitations of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation [J].
Cuvelier, A ;
Grigoriu, B ;
Molano, LC ;
Muir, JF .
CHEST, 2005, 127 (05) :1744-1748
[5]   ARTERIAL VERSUS CAPILLARY SAMPLING FOR ANALYZING BLOOD-GAS PRESSURES [J].
DAR, K ;
WILLIAMS, T ;
AITKEN, R ;
WOODS, KL ;
FLETCHER, S .
BRITISH MEDICAL JOURNAL, 1995, 310 (6971) :24-25
[6]   AARC Clinical Practice Guideline: Blood Gas Analysis and Hemoximetry: 2013 [J].
Davis, Michael D. ;
Walsh, Brian K. ;
Sittig, Steve E. ;
Restrepo, Ruben D. .
RESPIRATORY CARE, 2013, 58 (10) :1694-1703
[7]   Transcutaneous monitoring of blood gases: is it comparable with arterialized earlobe sampling? [J].
Dawson, S ;
Cave, C ;
Pavord, I ;
Potter, JF .
RESPIRATORY MEDICINE, 1998, 92 (03) :584-587
[8]   Sedation during Flexible Bronchoscopy in Patients with Pre-Existing Respiratory Failure: Midazolam versus Midazolam plus Alfentanil [J].
Dreher, Michael ;
Ekkernkamp, Emelie ;
Storre, Jan Hendrik ;
Kabitz, Hans-Joachim ;
Windisch, Wolfram .
RESPIRATION, 2010, 79 (04) :307-314
[9]   The clinical utility of arterialized earlobe capillary blood in the assessment of patients for long-term oxygen therapy [J].
Eaton, T ;
Rudkin, S ;
Garrett, JE .
RESPIRATORY MEDICINE, 2001, 95 (08) :655-660
[10]   The Design, Use, and Results of Transcutaneous Carbon Dioxide Analysis: Current and Future Directions [J].
Eberhard, Patrick .
ANESTHESIA AND ANALGESIA, 2007, 105 :S48-S52