Comparative study of 150 keV Ar+ and O+ ion implantation induced structural modification on electrical conductivity in Bakelite polymer

被引:7
作者
Kumar, K. V. Aneesh [1 ]
Krishnaveni, S. [1 ]
Asokan, K. [2 ]
Ranganathaiah, C. [3 ]
Ravikumar, H. S. [1 ]
机构
[1] Univ Mysore, Dept Studies Phys, Mysuru 570006, Karnataka, India
[2] IUAC, Aruna Asaf Ali Marg, New Delhi 110067, India
[3] JSS Tech Inst, JSSTI Campus, Mysuru 570006, Karnataka, India
关键词
Ion implantation; RPC detector material; Cross-linking; Free volume; Electrical conductivity; FREE-VOLUME; POSITRON-ANNIHILATION; DIFFUSION; RPC; IRRADIATION;
D O I
10.1016/j.jpcs.2017.10.023
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A comparative study of 150 keV argon (Ar+) and oxygen (O+) ion implantation induced microstructural modifications in Bakelite Resistive Plate Chamber (RPC) detector material at different implantation fluences have been studied using Positron Annihilation Lifetime Spectroscopy (PALS). Positron lifetime parameters viz., o-Ps lifetime (re) and its intensity (I-3) upon lower implantation fluences can be interpreted as the cross-linking and the increased local temperature induced diffusion followed by trapping of ions in the interior polymer voids. The increased o-Ps lifetime (tau(3)) at higher O+ ion implantation fluences indicates chain scission owing to the oxidation and track formation. This is also justified by the X-Ray Diffraction (XRD) and Fourier Transform Infrared (FTIR) results. The modification in the microstructure and electrical conductivity of Bakelite materials are more upon implantation of O+ ions than Ar+ ions of same energy and fluences. The reduced electrical conductivity of Bakelite polymer material upon ion implantation of both the ions is correlated to the conducting pathways and cross-links in the polymer matrix. The appropriate energy and fluence of implanting ions might reduce the leakage current and hence improve the performance of Bakelite RPC detectors.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 37 条
[1]   Aging study for resistive plate chambers of the CMS muon trigger detector [J].
Abbrescia, M ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Altieri, S ;
Belli, G ;
Bruno, G ;
Guida, R ;
Ratti, SP ;
Riccardi, C ;
Torre, P ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (1-2) :342-347
[2]   Positron annihilation and ion beam analysis of ion-bombardment-induced hydrogen release and oxidation of ultra high molecular weight polyethylene [J].
Al-Qaradawi, I. Y. ;
Madi, N. K. ;
Turos, A. ;
Abdul-Kader, A. M. .
RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (02) :123-128
[3]   Grafted natural rubber-based polymer electrolytes: ATR-FTIR and conductivity studies [J].
Ali, A. M. M. ;
Subban, R. H. Y. ;
Bahron, H. ;
Winie, T. ;
Latif, F. ;
Yahya, M. Z. A. .
IONICS, 2008, 14 (06) :491-500
[4]   Ageing tests on the low-resistivity RPC for the ALICE dimuon arm [J].
Arnaldi, R ;
Baldit, A ;
Barret, V ;
Bastid, N ;
Blanchard, G ;
Chiavassa, E ;
Cortese, P ;
Crochet, P ;
Dellacasa, G ;
De Marco, N ;
Drancourt, C ;
Dupieux, P ;
Espagnon, B ;
Ferretti, A ;
Forestier, B ;
Gallio, M ;
Genoux-Lubain, A ;
Insa, C ;
Jouve, F ;
Lamoine, L ;
Lefevre, F ;
Manso, F ;
Mereu, P ;
Musso, A ;
Oppedisano, C ;
Piccotti, A ;
Poggio, F ;
Royer, L ;
Rosnet, P ;
Saturnini, P ;
Scalas, E ;
Scomparin, E ;
Sigaudo, F ;
Travaglia, G ;
Vercellin, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 508 (1-2) :106-109
[5]   Development of 2 m x 2 m size glass RPCs for INO [J].
Bhuyan, M. ;
Datar, V. M. ;
Kalmani, S. D. ;
Lahamge, S. M. ;
Mohammed, S. ;
Mondal, N. K. ;
Nagaraj, P. ;
Redij, A. ;
Samuel, D. ;
Saraf, M. N. ;
Satyanarayana, B. ;
Shinde, R. R. ;
Verma, P. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 :S64-S67
[6]  
Carlson P., 2001, P NUCL SCI S MED IM, P1
[7]  
Chowdhury P, 2011, INDIAN J CHEM A, V50, P802
[8]   Compatibilization of recycled polymers through radiation treatment [J].
Czvikovszky, T ;
Hargitai, H .
RADIATION PHYSICS AND CHEMISTRY, 1999, 55 (5-6) :727-730
[9]   THE TEMPERATURE-DEPENDENCE OF POSITRON LIFETIMES IN SOLID PIVALIC ACID [J].
ELDRUP, M ;
LIGHTBODY, D ;
SHERWOOD, JN .
CHEMICAL PHYSICS, 1981, 63 (1-2) :51-58
[10]  
Fink D., 2004, Fundamentals of Ion-Irradiated Polymers