Analytical interference of quinolone antibiotics and quinine derived drugs on urinary protein determined by reagent strips and the pyrogallol red-molybdate protein assay

被引:11
作者
da Silva, Adriana Scotti [2 ]
Falkenberg, Miriam [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Ciencias Farmaceut, Ctr Ciencias Saude, Postgrad Program Pharm, BR-88040970 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Univ Hosp, Clin Lab Anal, BR-88040970 Florianopolis, SC, Brazil
关键词
Analytical interference; Antimalarial drugs; Ciprofloxacin; Hydroxychloroquine; Pyrogallol red-molybdate assay; Quinolones; Urinary protein; CHEMISTRY;
D O I
10.1016/j.clinbiochem.2011.05.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To investigate the analytical interference of drugs in urinary protein and to estimate the lowest interfering concentrations. Design and methods: Drug supplemented urine samples were compared to the control with two reagent strips and the total protein was determined using Pyrogallol Red-Molybdate (PRM). Results: False-positive interferences occurred with Multistix (R) 10 SG for hydroxychloroquine, levofloxacin and ofloxacin. No interference was observed with Combur (R) 10 Test M. Statistically significant false-positive interferences were observed in the PRM assay with all tested drugs, and lowest interfering concentrations were mostly above estimated therapeutic concentrations. The PRM assay "confirmed" the results of the Multistix dipstick, so a real proteinuria could be presumed from the double analytical interference. Conclusions: This is the first report of analytical interference by quinolone and quinine derivatives in the PRM assay. Special attention to patients using these drugs is needed to minimize errors in the interpretation of urinary protein results. (C) 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1000 / 1004
页数:5
相关论文
共 35 条
[1]  
[Anonymous], 1989, Scand J Clin Lab Invest Suppl, V195, P1
[2]  
[Anonymous], CURR PAEDIAT
[3]  
[Anonymous], 2007, MEDICINE
[4]   Quinolones and false-positive urine screening for opiates by immunoassay technology [J].
Baden, LR ;
Horowitz, G ;
Jacoby, H ;
Eliopoulos, GM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (24) :3115-3119
[5]  
Bonini P, 2002, CLIN CHEM, V48, P691
[6]  
Colombeli Adriana Scotti da Silva, 2006, J. Bras. Patol. Med. Lab., V42, P85, DOI 10.1590/S1676-24442006000200005
[7]   Analytical interferences of drugs in the chemical examination of urinary protein [J].
da Silva-Colombeli, Adriana Scotti ;
Falkenberg, Miriam .
CLINICAL BIOCHEMISTRY, 2007, 40 (13-14) :1074-1076
[8]  
FUJITA Y, 1983, BUNSEKI KAGAKU, V32, pE379
[9]  
Galteau M M, 1984, Ann Biol Clin (Paris), V42, P137
[10]  
Hartke K, 1987, DAB 9 KOMMENTAR, V3, P407