Automation of nanoflow liquid chromatography-tandem mass spectrometry for proteome and peptide profiling analysis by using a monolithic analytical capillary column

被引:13
作者
Jiang, Xiaogang [1 ,2 ]
Dong, Jing [1 ]
Wang, Fangjun [1 ]
Feng, Shun [1 ]
Ye, Mingliang [1 ]
Zou, Hanfa [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
[2] Suzhou Univ, Sch Med, Suzhou 215006, Peoples R China
关键词
automation; monolithic analytical capillary column; nano-LC-MS/MS; peptide separation; sample introduction;
D O I
10.1002/elps.200700513
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated nano-LC-MS/MS platform without trap column was established, which only used a 20 cm lauryl methacrylate-ethylene dimethacrylate (LMA-EDMA) monolithic capillary column to allow preconcentration and separation of peptides. The monolithic column had the advantages of good permeability and low backpressure resulting in higher flow rates for capillary columns. Tryptic digests of bovine albumin and yeast protein extract were tested using the monolithic column system. High proteomic coverage using this approach were demonstrated in this study. Furthermore, peptide samples extracted from mouse liver were separated by using the monolithic column system combined with size-exclusion chromatography prefractionation. This monolithic column system might be a promising alternative for the automated system previously using a trap column for routine proteome and peptide profiling analysis.
引用
收藏
页码:1612 / 1618
页数:7
相关论文
共 38 条
[1]  
Devreese B, 2001, RAPID COMMUN MASS SP, V15, P50, DOI 10.1002/1097-0231(20010115)15:1<50::AID-RCM191>3.0.CO
[2]  
2-V
[3]   Capillary electrochromatography with a neutral monolithic column for classification of analytes and determination of basic drugs in human serum [J].
Dong, J ;
Xie, CH ;
Tian, RJ ;
Wu, RN ;
Hu, JW ;
Zou, HF .
ELECTROPHORESIS, 2005, 26 (18) :3452-3459
[4]   Coupling the immobilized trypsin microreactor of monolithic capillary with μRPLC-MS/MS for shotgun proteome analysis [J].
Feng, S ;
Ye, ML ;
Jiang, XG ;
Jin, WH ;
Zou, HF .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (02) :422-428
[5]   Fe3+ immobilized metal affinity chromatography with silica monolithic capillary column for phosphoproteome analysis [J].
Feng, Shun ;
Pan, Chensong ;
Jiang, Xiaogang ;
Xu, Songyu ;
Zhou, Houjiang ;
Ye, Mingliang ;
Zou, Hanfa .
PROTEOMICS, 2007, 7 (03) :351-360
[6]   Efficient polymer monolith for strong cation-exchange capillary liquid chromatography of peptides [J].
Gu, Binghe ;
Chen, Zhaoyuan ;
Thulin, Craig D. ;
Lee, Milton L. .
ANALYTICAL CHEMISTRY, 2006, 78 (11) :3509-3518
[7]   Low-molecular-weight human serum proteome using ultrafiltration, isoelectric focusing, and mass spectrometry [J].
Harper, RG ;
Workman, SR ;
Schuetzner, S ;
Timperman, AT ;
Sutton, JN .
ELECTROPHORESIS, 2004, 25 (09) :1299-1306
[8]   Comprehensive peptidome analysis of mouse livers by size exclusion chromatography prefractionation and NanoLC-MS/MS identification [J].
Hu, Lianghai ;
Li, Xin ;
Jiang, Xinning ;
Zhou, Houjiang ;
Jiang, Xiaogang ;
Kong, Liang ;
Ye, Mingliang ;
Zou, Hanfa .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (02) :801-808
[9]   Method development of efficient protein extraction in bone tissue for proteome analysis [J].
Jiang, Xiaogang ;
Ye, Mingliang ;
Jiang, Xinning ;
Liu, Guangpeng ;
Feng, Shun ;
Cui, Lei ;
Zou, Hanfa .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (06) :2287-2294
[10]   Automation of nanoflow liquid chromatography-tandem mass spectrometry for proteome analysis by using a strong cation exchange trap column [J].
Jiang, Xiaogang ;
Feng, Shun ;
Tian, Ruijun ;
Han, Guanghui ;
Jiang, Xinning ;
Ye, Mingliang ;
Zou, Hanfa .
PROTEOMICS, 2007, 7 (04) :528-539