Closure of Patent Foramen Ovale Defects Using GORE® CARDIOFORM Septal Occluder: Results From a Prospective European Multicenter Study

被引:18
作者
Hardt, Stefan E. [1 ,2 ]
Eicken, Andreas [3 ]
Berger, Felix [4 ]
Schubert, Stephan [4 ]
Carminati, Mario [5 ]
Butera, Gianfranco [5 ]
Grohmann, Jochen [6 ]
Hoehn, Rene [6 ]
Nielsen-Kudsk, Jens Erik [7 ]
Hildick-Smith, David [8 ]
Settergren, Magnus [9 ]
Thomson, John D. [10 ]
Geis, Nicolas [1 ]
Sondergaard, Lars [11 ]
机构
[1] Heidelberg Univ, Dept Cardiol Angiol & Pulmol, Heidelberg, Germany
[2] Ctr Cardiac & Circulatory Dis, Hoheneggerstr 9, D-76646 Bruchsal, Germany
[3] Tech Univ Munich, Deutsch Herzzentrum Munchen, Dept Pediat Cardiol & Congenital Heart Dis, Munich, Germany
[4] Deutsch Herzzentrum Berlin, Klin Kinderkardiol & Angeborene Herzfehler, Berlin, Germany
[5] IRCCS Policlin San Donato, Dept Paediat Cardiol & Cardiac Surg & Adult Conge, I-20097 Milan, Italy
[6] Univ Freiburg, Heart Ctr, Dept Congenital Heart Defects & Pediat Cardiol, Freiburg, Germany
[7] Aarhus Univ, Hosp Skejby, Inst Clin Med, Dept Cardiol Res, DK-8200 Aarhus N, Denmark
[8] Sussex Cardiac Ctr, Dept Cardiol, Brighton, E Sussex, England
[9] Karolinska Univ Hosp, Dept Cardiol, Stockholm, Sweden
[10] Leeds Gen Infirm, Dept Congenital Cardiol, Leeds, W Yorkshire, England
[11] Univ Hosp, Heart Ctr, Rigshosp, DK-2100 Copenhagen, Denmark
关键词
closure; ASD/PDA/PFO; stroke; structural heart disease intervention; TRANSCATHETER CLOSURE; PERCUTANEOUS CLOSURE; CLINICAL-EXPERIENCE; DEVICES; AMPLATZER; CHILDREN; PFO; GSO;
D O I
10.1002/ccd.26993
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The GORE (R) CARDIOFORM Septal Occluder (GSO) is a novel device designed for rapid and effective closure of patent foramen ovale (PFO) which has distinctive features making it suitable for a broad spectrum of anatomical variations. We report the procedural and 6 months follow-up results of the first prospective, multicenter study using GSO. Methods and Results: This single-arm study included 150 subjects undergoing closure of PFO in 10 European centers. In 149 out of 150 patients implantation of a GSO device was successful. One patient had a different PFO-closure device implanted. Periprocedural complications were few including one patient with suspected transient ischemic attack, two access site bleedings, and one patient with AV-fistula. No device embolization occurred. During the 6-month follow-up period one patient had a transient asymptomatic thrombus on the device and four patients (2.6%) were diagnosed new onset paroxysmal atrial fibrillation, which were successfully treated. No thrombembolic events occurred. Closure was successful in 94.2% of subjects at discharge evaluation and 96.9% at 6 months follow-up. Conclusion: This prospective, multicenter study adds to previous published data and suggests that GSO is a versatile device for PFO closure with high procedural and closure success rates and low complication rates through mid-term follow-up. (C) 2017 Wiley Periodicals, Inc.
引用
收藏
页码:824 / 829
页数:6
相关论文
共 50 条
  • [31] Percutaneous Closure of Atrial Septal Defects with the MemoPart Atrial Septal Occluder: The Early-Term Results of a Multicenter Study
    Baykan, Ali
    Bilici, Meki
    Narin, Nazmi
    Erdem, Abdullah
    Uzum, Kazim
    Akin, Alper
    Pamukcu, Ozge
    Balik, Hasan
    Ture, Mehmet
    Vural, Cagdas
    Dogan, Alper
    PEDIATRIC CARDIOLOGY, 2022, 43 (01) : 39 - 44
  • [32] Mid-term results of interventional closure of patent foramen ovale with the Occlutech Figulla® Flex II Occluder
    Neuser, Jonas
    Akin, Muharrem
    Bavendiek, Udo
    Kempf, Tibor
    Bauersachs, Johann
    Widder, Julian D.
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [33] Application of Transesophageal Echocardiography in Amplatzer Atrial Septal Defect Occluder for Percutaneous Closure of Large Patent Foramen Ovale
    Du, Yajuan
    Xie, Hang
    Shao, Hui
    Cheng, Gesheng
    He, Lu
    Wang, Xingye
    He, Xumei
    Lan, Beidi
    Zhang, Yushun
    Tian, Gang
    CARDIOVASCULAR THERAPEUTICS, 2022, 2022
  • [34] Results of the US multicenter pivotal study of the HELEX septal occluder for percutaneous closure of secundum atrial septal defects
    Jones, Thomas K.
    Latson, Larry A.
    Zahn, Evan
    Fleishman, Craig E.
    Jacobson, Joth
    Vincent, Robert
    Kanter, Kirk
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (22) : 2215 - 2221
  • [35] Patent foramen ovale closure in patients with cryptogenic thrombo-embolic events using the Cardia PFO occluder
    Spies, C
    Strasheim, R
    Timmermanns, I
    Schraeder, R
    EUROPEAN HEART JOURNAL, 2006, 27 (03) : 365 - 371
  • [36] Amplatzer or Figulla Flex II Occluder: A Comparative Study of Outcomes After Transcatheter Patent Foramen Ovale Closure
    Toggweiler, Stefan
    Moccetti, Federico
    Conrad, Nina
    Loretz, Lucca
    Madanchi, Mehdi
    Bossard, Matthias
    Attiger-Toller, Adrian
    Cuculi, Florim
    Wolfrum, Mathias
    JOURNAL OF INVASIVE CARDIOLOGY, 2024, 36 (04)
  • [37] UK Multicenter Experience Using the Gore Septal Occluder (GSO™) for Atrial Septal Defect Closure in Children and Adults
    Smith, Ben
    Thomson, John
    Crossland, David
    Spence, Mark S.
    Morgan, Gareth J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (04) : 581 - 586
  • [38] Incidence of atrial fibrillation after percutaneous closure of patent foramen ovale and small atrial septal defects in patients presenting with cryptogenic stroke
    Bonvini, R. F.
    Sztajzel, R.
    Dorsaz, P. -A.
    Righini, M.
    Bonvin, C.
    Alibegovic, J.
    Sigwart, U.
    Camenzind, E.
    Verin, V.
    Sztajzel, J.
    INTERNATIONAL JOURNAL OF STROKE, 2010, 5 (01) : 4 - 9
  • [39] Percutaneous Closure of Atrial Septal Defects with the MemoPart Atrial Septal Occluder: The Early-Term Results of a Multicenter Study
    Ali Baykan
    Meki Bilici
    Nazmi Narin
    Abdullah Erdem
    Kazim Uzum
    Alper Akin
    Ozge Pamukcu
    Hasan Balik
    Mehmet Ture
    Cagdas Vural
    Alper Dogan
    Pediatric Cardiology, 2022, 43 : 39 - 44
  • [40] Echocardiographic characteristics of transcatheter closure of patent foramen ovale with mallow biodegradable occluder: A single-center, phase III clinical study
    Song, Lin
    Shi, Peixuan
    Zheng, Xiaozhou
    Hongxin, Li
    Li, Ziang
    Lv, Meng
    Wang, Haiyan