Closure of Patent Foramen Ovale Defects Using GORE® CARDIOFORM Septal Occluder: Results From a Prospective European Multicenter Study

被引:18
|
作者
Hardt, Stefan E. [1 ,2 ]
Eicken, Andreas [3 ]
Berger, Felix [4 ]
Schubert, Stephan [4 ]
Carminati, Mario [5 ]
Butera, Gianfranco [5 ]
Grohmann, Jochen [6 ]
Hoehn, Rene [6 ]
Nielsen-Kudsk, Jens Erik [7 ]
Hildick-Smith, David [8 ]
Settergren, Magnus [9 ]
Thomson, John D. [10 ]
Geis, Nicolas [1 ]
Sondergaard, Lars [11 ]
机构
[1] Heidelberg Univ, Dept Cardiol Angiol & Pulmol, Heidelberg, Germany
[2] Ctr Cardiac & Circulatory Dis, Hoheneggerstr 9, D-76646 Bruchsal, Germany
[3] Tech Univ Munich, Deutsch Herzzentrum Munchen, Dept Pediat Cardiol & Congenital Heart Dis, Munich, Germany
[4] Deutsch Herzzentrum Berlin, Klin Kinderkardiol & Angeborene Herzfehler, Berlin, Germany
[5] IRCCS Policlin San Donato, Dept Paediat Cardiol & Cardiac Surg & Adult Conge, I-20097 Milan, Italy
[6] Univ Freiburg, Heart Ctr, Dept Congenital Heart Defects & Pediat Cardiol, Freiburg, Germany
[7] Aarhus Univ, Hosp Skejby, Inst Clin Med, Dept Cardiol Res, DK-8200 Aarhus N, Denmark
[8] Sussex Cardiac Ctr, Dept Cardiol, Brighton, E Sussex, England
[9] Karolinska Univ Hosp, Dept Cardiol, Stockholm, Sweden
[10] Leeds Gen Infirm, Dept Congenital Cardiol, Leeds, W Yorkshire, England
[11] Univ Hosp, Heart Ctr, Rigshosp, DK-2100 Copenhagen, Denmark
关键词
closure; ASD/PDA/PFO; stroke; structural heart disease intervention; TRANSCATHETER CLOSURE; PERCUTANEOUS CLOSURE; CLINICAL-EXPERIENCE; DEVICES; AMPLATZER; CHILDREN; PFO; GSO;
D O I
10.1002/ccd.26993
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The GORE (R) CARDIOFORM Septal Occluder (GSO) is a novel device designed for rapid and effective closure of patent foramen ovale (PFO) which has distinctive features making it suitable for a broad spectrum of anatomical variations. We report the procedural and 6 months follow-up results of the first prospective, multicenter study using GSO. Methods and Results: This single-arm study included 150 subjects undergoing closure of PFO in 10 European centers. In 149 out of 150 patients implantation of a GSO device was successful. One patient had a different PFO-closure device implanted. Periprocedural complications were few including one patient with suspected transient ischemic attack, two access site bleedings, and one patient with AV-fistula. No device embolization occurred. During the 6-month follow-up period one patient had a transient asymptomatic thrombus on the device and four patients (2.6%) were diagnosed new onset paroxysmal atrial fibrillation, which were successfully treated. No thrombembolic events occurred. Closure was successful in 94.2% of subjects at discharge evaluation and 96.9% at 6 months follow-up. Conclusion: This prospective, multicenter study adds to previous published data and suggests that GSO is a versatile device for PFO closure with high procedural and closure success rates and low complication rates through mid-term follow-up. (C) 2017 Wiley Periodicals, Inc.
引用
收藏
页码:824 / 829
页数:6
相关论文
共 50 条
  • [21] Intermediate and Long-Term Results of Transcatheter Closure of Patent Foramen Ovale Using the Amplatzer Patent Foramen Ovale Occluder: One Case of Pulmonary Embolism Irrespective of Patent Foramen Ovale Closure
    Yoon, Ju Hee
    Kim, Joon Sik
    Lee, Dae Hyung
    Shim, Eun Jung
    Lee, So Yeon
    Min, Ki Sik
    Cho, Do Jun
    Lee, Hye Ran
    KOREAN CIRCULATION JOURNAL, 2011, 41 (07) : 356 - 362
  • [22] Percutaneous closure of patent foramen ovale and atrial septal aneurysm using the Atriasept™ II PFO occluder: clinical and technical implications
    Brown, Stephen
    Buys, Daniel
    CARDIOVASCULAR JOURNAL OF AFRICA, 2012, 23 (01) : E18 - E21
  • [23] Gore Helex Septal Occluder for Percutaneous Closure of Patent Foramen Ovale Associated With Atrial Septal Aneurysm: Short- and Mid-Term Clinical and Echocardiographic Outcomes
    Musto, Carmine
    Cifarelli, Alberta
    Fiorilli, Rosario
    De Felice, Francesco
    Parma, Antonio
    Pandolfi, Claudia
    Confessore, Pierpaolo
    Bernardi, Leda
    Violini, Roberto
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10): : 510 - 514
  • [24] Is Routine Ultrasound Guidance Really Necessary for Closure of Patent Foramen Ovale Using the Amplatzer PFO Occluder?
    Fateh-Moghadam, Suzanne
    Steeg, Martin
    Dietz, Rainer
    Bocksch, Wolfgang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (03) : 361 - 366
  • [25] Suture-Mediated Patent Foramen Ovale Closure Using the NobleStitch EL: Results from a Hospital-Based HTA
    Gaetti, Giovanni
    Beneduce, Alessandro
    La Fauci, Dario
    Scardoni, Alessandro
    Chiappa, Federica
    Bellini, Lorenzo
    Franzin, Michela
    Natale, Anna Maria
    Marras, Paola
    Ranieri, Paolo
    Signorelli, Carlo
    Bossi, Eleonora
    Ferrario, Lucrezia
    Foglia, Emanuela
    Montorfano, Matteo
    Odone, Anna
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (13)
  • [26] ASSURED clinical study: New GORE® CARDIOFORM ASD occluder for transcatheter closure of atrial septal defect
    Sommer, Robert J.
    Love, Barry A.
    Paolillo, Joseph A.
    Gray, Robert G.
    Goldstein, Bryan H.
    Morgan, Gareth J.
    Gillespie, Matthew J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (07) : 1285 - 1295
  • [27] Multicenter Midterm Follow-Up Results Using the Gore Septal Occluder for Atrial Septal Defect Closure in Pediatric Patients
    Grohmann, Jochen
    Wildberg, Christian
    Zartner, Peter
    Abu-Tair, Tariq
    Tarusinov, Gleb
    Kitzmueller, Erwin
    Schmoor, Claudia
    Stiller, Brigitte
    Kampmann, Christoph
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (07) : E226 - E232
  • [28] Recurrent and Residual Shunts After Patent Foramen Ovale Closure: Results From a Long-Term Transcranial Doppler Study
    Cheli, Martino
    Canepa, Marco
    Brunelli, Claudio
    Bezante, Gian Paolo
    Favorini, Serena
    Rollando, Daniela
    Sivori, Giorgia
    Viani, Erica
    Finocchi, Cinzia
    Balbi, Manrico
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2015, 28 (06) : 600 - 608
  • [29] Mullins-Sheath Facilitated Delivery of Gore Cardioform ASD Occluder Devices for Closure of Large or Challenging Secundum Atrial Septal Defects
    Eilers, Lindsay F.
    Gowda, Srinath T.
    Gowda, Shaila
    Lahiri, Subhrajit
    Aggarwal, Varun
    Stapleton, Gary E.
    Gillespie, Matthew J.
    Qureshi, Athar M.
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06): : E425 - +
  • [30] In vivo study of a reserved atrial septal puncture area patent foramen ovale occluder
    Jiang, Haibin
    Cao, Suyan
    Wang, Renrong
    Wang, Shuya
    He, Ziqian
    Xu, Xin
    Yang, Chengjian
    Liu, Xiaoxiao
    CARDIOLOGY IN THE YOUNG, 2023, 33 (09) : 1581 - 1586