Study of Concrete under Combined Action of Aggressive Environment and Long-Term Loading

被引:11
作者
Blikharskyy, Yaroslav [1 ]
Selejdak, Jacek [2 ]
Kopiika, Nadiia [3 ]
Vashkevych, Rostyslav [3 ]
机构
[1] Lviv Polytech Natl Univ, Dept Highways & Bridges, 12 St S Bandera, UA-79013 Lvov, Ukraine
[2] Czestochowa Tech Univ, Fac Civil Engn, 69 St Dabrowskiego, PL-42201 Czestochowa, Poland
[3] Lviv Polytech Natl Univ, Dept Bldg Construct & Bridges, 12 St S Bandera, UA-79013 Lvov, Ukraine
关键词
corrosion damages; concrete corrosion; material properties; corrosion in RC constructions; REINFORCED-CONCRETE; STAINLESS-STEEL; CORROSION RATE; ACID; DAMAGE; REBAR;
D O I
10.3390/ma14216612
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A significant part of reinforced concrete structures is subjected to intensive environmental impact during operation. This can cause local destruction and failure of buildings if obligatory measures are not taken to protect them from corrosion. This is especially true for industrial buildings, where the environment could be contaminated with aggressive products or waste. An important issue is the development of methods for calculating the load-bearing capacity and serviceability of reinforced concrete structures with corrosion damage. The main reason for this is the necessity to determine the durability and reliability of buildings and structures and the estimation of their safe operation time. As corrosion damages of concrete are a critical issue, more detailed experimental studies are needed. This paper presents experimental studies of concrete prisms under the simultaneous action of an aggressive environment and a constant level of compressive force. In total, 32 prisms under different loading conditions and in different aggressive medium were tested. Samples were divided in series, for which different load levels were chosen (0.25f(ck), 0.35f(ck), 0.45f(ck)). Additionally, control samples in the air and immersed in water were tested. During the experiment, different parameters were monitored and recorded: decrease of cross-sectional size, the temperature and environmental humidity. Results of the study showed that destruction occurred due to the presence of corrosion damages of concrete and a reduction of the cross-sectional area. The stresses in the concrete at the destruction stage were less than the value of the prism strength by 10-12%. It was established that along the contour of the section, there is a partially degraded layer of concrete of 1.5-3.7 mm thickness, with corrosion microcracks and corrosion products. Additionally, experimental and theoretical diagrams of concrete with corrosion damages were obtained and compared. The ultimate deformations of concrete with corrosion damage, which correspond to the prismatic strength of concrete, in comparison with undamaged concrete were lower by 11-18%. Therefore, the concrete strength is decreased during exploitation under loading in an aggressive environment, which needs to be taken into account during calculations.
引用
收藏
页数:21
相关论文
共 46 条
  • [21] Jedidi M., 2018, MOJ Civ. Eng, V4, P40, DOI [10.15406/mojce.2018.04.00095, DOI 10.15406/MOJCE.2018.04.00095]
  • [22] Corrosion mechanisms in reinforced concrete by acoustic emission
    Kawasaki, Yuma
    Wakuda, Tomoyo
    Kobarai, Tomoe
    Ohtsu, Masayasu
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 : 1240 - 1247
  • [23] Klimecka-Tatar D., 2020, Materials Research Proceedings, V17, P72, DOI [10.21741/9781644901038-11, DOI 10.21741/9781644901038-11]
  • [24] Kotes P., 2018, IOP Conference Series: Materials Science and Engineering, V385, DOI 10.1088/1757-899X/385/1/012031
  • [25] Kusak Ivo, 2014, Advanced Materials Research, V897, P131, DOI 10.4028/www.scientific.net/AMR.897.131
  • [26] Kusak Ivo, 2013, Applied Mechanics and Materials, V248, P370, DOI 10.4028/www.scientific.net/AMM.248.370
  • [27] Monitoring of concrete hydration by electrical measurement methods
    Kusak, Ivo
    Lunak, Miroslav
    Chobola, Zdenek
    [J]. ECOLOGY AND NEW BUILDING MATERIALS AND PRODUCTS 2016, 2016, 151 : 271 - 276
  • [28] Corrosion of the 1.4362 Duplex Stainless Steel in a Nitric Acid Environment at 333 K
    Lipinski, T.
    [J]. ACTA PHYSICA POLONICA A, 2019, 135 (02) : 203 - 206
  • [29] Investigation of corrosion rate of X55CrMo14 stainless steel at 65% nitrate acid at 348 K
    Lipinski, Tomasz
    [J]. PRODUCTION ENGINEERING ARCHIVES, 2021, 27 (02) : 108 - 111
  • [30] Influence of inclusions on bending fatigue strength coefficient the medium carbon steel melted in an electric furnace
    Lipinski, Tomasz
    Wach, Anna