Two-Dimensional Longitudinal Strain in Patients with Aortic Stenosis Can Be Reliably Acquired at the Bedside without Additional Benefit of Offline Analysis

被引:4
作者
Beaver, Timothy A. [1 ]
Steiner, Johannes [2 ]
Sullivan, Clyde D. [3 ]
Costa, Salvatore P.
Palac, Robert T.
机构
[1] Dartmouth Hitchcock Med Ctr, Cardiol Sect, Dept Med, Lebanon, NH 03756 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Internal Med, Lebanon, NH 03756 USA
[3] Dartmouth Hitchcock Med Ctr, Dept Cardiol, Lebanon, NH 03756 USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2011年 / 28卷 / 01期
关键词
SPECKLE-TRACKING ECHOCARDIOGRAPHY; MYOCARDIAL-FUNCTION; DOPPLER; VALIDATION; REPRODUCIBILITY; DEFORMATION; ACCURACY;
D O I
10.1111/j.1540-8175.2010.01275.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Two-dimensional strain echocardiography (2DS) has been used to assess ventricular function in several disease states. In previous studies of 2DS, strain analysis was usually performed offline by experienced echocardiographers. The applicability of 2DS in busy clinical labs would be enhanced if 2DS could be reproducibly measured by sonographers at the time of the echo exam. In this study we compared the reproducibility of strain measurements between sonographers at the time of the echo exam with those performed offline by an experienced echocardiographer. Methods: Apical left ventricular (LV) B-mode images were acquired in 98 consecutive patients being evaluated for aortic stenosis. 2DS analysis was performed at the time of the exam by a sonographer. The same images were analyzed offline by an experienced echocardiographer. Global longitudinal strain (GLS) results were analyzed for interobserver reproducibility. Additionally, the regional longitudinal strain (RLS) of 20 randomly selected patients was analyzed for intraobserver reproducibility. Results: Acceptable data quality was available in 97.8% of the segments measured at the time of the exam and in 96.9% at the workstation. Interobserver reproducibility of the global peak strain was high (r = 0.855, P < 0.001). Additionally, applying cutoffs for separating normal from abnormal GLS revealed good agreement between sonographer and experienced echocardiographer [kappa analysis (kappa = 0.739, P < 0.001)]. Overall RLS intraobserver reproducibility was high (raw mean adjusted r = 0.915). Conclusion: The GLS in aortic stenosis patients can be reliably measured at the bedside by a sonographer without additional benefit of offline analysis. (Echocardiography 2011;28:22-28).
引用
收藏
页码:22 / 28
页数:7
相关论文
共 18 条
[1]  
AMUNDSEN BH, 2009, EUR J ECHOCARDIOGR
[2]   Feasibility and Accuracy of Different Techniques of Two-Dimensional Speckle Based Strain and Validation With Harmonic Phase Magnetic Resonance Imaging [J].
Bansal, Manish ;
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Haluska, Brian A. ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) :1318-1325
[3]   Automated function imaging: a new operator-independent strain method for assessing left ventricular function [J].
Belghiti, H. ;
Brette, S. ;
Lafitte, S. ;
Reant, P. ;
Picard, F. ;
Serri, K. ;
Lafitte, M. ;
Courregelongue, M. ;
Dos Santos, P. ;
Douard, H. ;
Roudaut, R. ;
DeMaria, A. .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2008, 101 (03) :163-169
[4]   3-D correlation-based speckle tracking [J].
Chen, X ;
Xie, H ;
Erkamp, R ;
Kim, K ;
Jia, C ;
Rubin, JM ;
O'Donnell, M .
ULTRASONIC IMAGING, 2005, 27 (01) :21-36
[5]   Comparison of two-dimensional speckle and tissue velocity based strain and validation with harmonic phase magnetic resonance imaging [J].
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Strudwick, Mark ;
Marwick, Thomas H. .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11) :1661-1666
[6]   New noninvasive method for assessment of left ventricular rotation - Speckle tracking echocardiography [J].
Helle-Valle, T ;
Crosby, J ;
Edvardsen, T ;
Lyseggen, E ;
Amundsen, BH ;
Smith, HJ ;
Rosen, BD ;
Lima, JAC ;
Torp, H ;
Ihlen, H ;
Smiseth, OA .
CIRCULATION, 2005, 112 (20) :3149-3156
[7]   Direct ultrasound measurement of longitudinal, circumferential, and radial strain using 2-dimensional strain imaging in normal adults [J].
Hurlburt, Heather M. ;
Aurigemma, Gerard P. ;
Hill, Jeffrey C. ;
Narayanan, Arumugam ;
Gaasch, William H. ;
Vinch, Craig S. ;
Meyer, Theo E. ;
Tighe, Dennis A. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (07) :723-731
[8]   Accuracy, reproducibility, and comparability of Doppler tissue imaging by two high-end ultrasound systems [J].
Kjaergaard, J ;
Korinek, J ;
Belohlavek, M ;
Oh, JK ;
Sogaard, P ;
Hassager, C .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (03) :322-328
[9]   Two-dimensional strain - a Doppler-independent ultrasound method for quantitation of regional deformation: Validation in vitro and in vivo [J].
Korinek, J ;
Wang, JW ;
Sengupta, PP ;
Miyazaki, C ;
Kjaergaard, J ;
McMahon, E ;
Abraham, TP ;
Belohlavek, M .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1247-1253
[10]   Two-dimensional strain - A novel software for real-time quantitative echocardiographic assessment of myocardial function [J].
Leitman, M ;
Lysyansky, P ;
Sidenko, S ;
Shir, V ;
Peleg, E ;
Binenbaum, M ;
Kaluski, E ;
Krakover, R ;
Vered, Z .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (10) :1021-1029