A study of neutron activation analysis compared to inductively coupled plasma atomic emission spectrometry for geological samples in Iran

被引:5
作者
Mohammadzadeh, Mohammad [1 ]
Ajami, Mona [2 ]
Shadeghipanah, Arash [3 ]
Rezvanifard, Mehdi [4 ]
机构
[1] Shahid Beheshti Univ, GC, Dept Radiat Med, Tehran 1983969411, Iran
[2] Shahid Beheshti Univ, GC, Dept Nucl Engn, Tehran 1983969411, Iran
[3] Shahid Beheshti Univ, GC, Dept Radiat Applicat, Tehran 1983969411, Iran
[4] NSTRI, Reactor Res & Nucl Safety Sch, Tehran 1439951113, Iran
关键词
Geological samples; Detection limit; Neutron activation analysis; MCNPX; ICP-AES; ORIGEN;
D O I
10.1016/j.net.2018.07.015
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) is widely used for the determination of trace elements in geological samples in Iran. In this paper, we have calculated the detection limits of neutron activation analysis (NAA) for some of the common elements in such samples utilizing the ORIGEN and MCNP codes and verified the simulations using the experimental results of three soil standard reference materials, namely, G02.SRM, G18.SRM, and G28.SRM. The results show that while the detection limit of ICP-AES method is usually in the mg/kg range, it is represented to the mu g/kg range for most of the elements of interest using the NAA method, and the simulations can be verified in a tolerance range of 20%. (C) 2018 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1349 / 1354
页数:6
相关论文
共 15 条
[1]  
Ahmed Y.A., 2006, LOW POWER MINIATURE
[2]  
Alfassi ZeevB., 1990, Activation Analysis, VI
[3]  
[Anonymous], ICP OES DETECTION LI
[4]  
Bell M.J., 1973, ORNL4628
[5]  
Briesmeister J. F., 2000, LA13709M OAK RIDG NA
[6]  
Croft S., 1987, PHYS B, V38, P149
[8]   Determination of matrix elements of As-S glasses by inductively coupled plasma atomic emission spectrometry [J].
Evdokimov, I. I. ;
Fadeeva, D. A. ;
Pimenov, V. G. .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2018, 480 :34-37
[9]   Metal and trace element assessments of bottom sediments from medium Tiet River basin, Sao Paulo State, Brazil: part II [J].
Favaro, D. I. T. ;
Rocha, F. R. ;
Angelini, M. ;
Henriques, H. R. A. ;
Soares, J. S. ;
Silva, P. S. C. ;
Oliveira, S. M. B. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 316 (02) :805-818
[10]   Comparative PGAA and NAA results of geological samples and standards [J].
Gmeling, K. ;
Simonits, A. ;
Laszlo, I. Sziklai ;
Parkanyi, D. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) :507-516