Optical heterodyne surface plasmon resonance biosensor

被引:0
作者
Chou, C [1 ]
Kuo, WC [1 ]
Wu, HT [1 ]
机构
[1] Natl Yang Ming Univ, Inst Radiol Sci, Taipei 112, Taiwan
来源
OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS III | 2003年 / 4957卷
关键词
surface plasma wave (SPW); surface plasmon resonance (SPR); biosensor; optical heterodyne;
D O I
10.1117/12.476721
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel optical heterodyne surface plasmon resonance (SPR) biosensor using Zeeman laser is proposed. There are two surface plasma waves (SPWs) being excited by two correlated P polarized waves in an SPR device of Kretschmann configuration. The two reflected P waves are optically heterodyned so that. the magnitude of the heterodyned signal is proportional to the multiplication of two attenuated reflected P waves. Then the detection sensitivity and the dynamical range based on this amplitude sensitive method are enhanced. In the experiment, the kinetics between mouse IgG and anti-mouse IgG is obtained according to the sensograms of, different concentrations of anti-mouse IgG The detection sensitivity corresponding to 0.2 nM is achieved. In addition, a concentration of 5 ng/ml of protein G interacting with mouse IgG is measured successfully.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 13 条
[1]  
*AFF SENS, IAS APPL NOT 2 1
[2]   Interferometric sensor for detection of surface-bound bioreactions [J].
Brandenburg, A ;
Krauter, R ;
Künzel, C ;
Stefan, M ;
Schulte, H .
APPLIED OPTICS, 2000, 39 (34) :6396-6405
[3]   Determination of the refractive index increments of small molecules for correction of surface plasmon resonance data [J].
Davis, TM ;
Wilson, WD .
ANALYTICAL BIOCHEMISTRY, 2000, 284 (02) :348-353
[4]   BIOSPECIFIC INTERACTION ANALYSIS USING SURFACE-PLASMON RESONANCE DETECTION APPLIED TO KINETIC, BINDING-SITE AND CONCENTRATION ANALYSIS [J].
FAGERSTAM, LG ;
FROSTELLKARLSSON, A ;
KARLSSON, R ;
PERSSON, B ;
RONNBERG, I .
JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2) :397-410
[5]   Surface plasmon resonance sensors: review [J].
Homola, J ;
Yee, SS ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :3-15
[6]   An amperometric biosensor for real-time analysis of molecular recognition [J].
Ivnitski, D ;
Wolf, T ;
Solomon, B ;
Fleminger, G ;
Rishpon, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (01) :27-32
[7]   Sensitivity and detection limit of concentration and adsorption measurements by laser-induced surface-plasmon resonance [J].
Kolomenskii, AA ;
Gershon, PD ;
Schuessler, HA .
APPLIED OPTICS, 1997, 36 (25) :6539-6547
[8]  
KUO WC, 2001, P OPT PHOT TAIW 01, V1, P325
[10]   DETERMINATION OF RATE AND EQUILIBRIUM BINDING CONSTANTS FOR MACROMOLECULAR INTERACTIONS USING SURFACE-PLASMON RESONANCE - USE OF NONLINEAR LEAST-SQUARES ANALYSIS-METHODS [J].
OSHANNESSY, DJ ;
BRIGHAMBURKE, M ;
SONESON, KK ;
HENSLEY, P ;
BROOKS, I .
ANALYTICAL BIOCHEMISTRY, 1993, 212 (02) :457-468