Validation of 3D-laser surface registration for image-guided cranio-maxillofacial surgery

被引:65
作者
Hoffmann, J
Westendorff, C
Leitner, C
Bartz, D
Reinert, S
机构
[1] Univ Tubingen Hosp, Dept Oral & Maxillofacial Plast Surg, D-72076 Tubingen, Germany
[2] Univ Tubingen, Wilhelm Schickard Inst Comp Sci, Dept Graph Interact Syst, Tubingen, Germany
关键词
image-guided minimally invasive surgery; laser surface scanning; patient registration; navigation-assisted cranio-maxillofacial surgery;
D O I
10.1016/j.jcms.2004.10.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Image-data-based navigation plays an important role during surgical treatment in anatomically complex areas. Conventional patient-to-image registration techniques on the basis of skin and bone markers require expensive and time-consuming logistic support. A new markerless, high-resolution laser surface scan technique for patient registration has been tested in experimental and clinical settings. Methods: In a phantom study, a skull model was registered with laser scanning and marker-based algorithms. The registration procedure was repeated 25 times in each group. The values for the root mean-square error were calculated as a measure of the deviation of the forecast position from the actual position and the target difference. In a clinical setting, 21 consecutive patients who presented with cranio-maxillofacial disorders were scheduled for navigational surgery using laser surface scanning for patient-to-image registration. Here the accuracy was determined by anatomical landmark localization. Results: In the experimental study, a root mean-square error of 1.3+/-0.14mm, and a mean target deviation of 2.08+/-0.49mm were found for laser scanning. In contrast, a root mean-square error of 0.38+/-0.01mm and a mean target deviation of 0.99+/-0.15mm were found for marker registration. The differences were statistically significant (p < 0.005). A strong correlation between the root mean-square error and the target deviation was found for laser (r = 0.96) and marker registration (r = 0.95). During the 21 clinical procedures, the overall accuracy of laser scan registration determined by the root mean-square error was 1.21+/-0.34mm, and the mean clinical precision was 1.8+/-0.5mm. Conclusions: Three-dimensional laser surface registration offers an interesting approach for selected image-guided procedures in cranio-maxillofacial surgery. (C) 2004 European Association for Cranio-Maxillofacial Surgery.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 28 条
[1]  
Alp MS, 1998, NEUROL RES, V20, P31
[2]   3 DIMENSIONAL DIGITIZATION OF THE FACE AND SKULL [J].
ARRIDGE, S ;
MOSS, JP ;
LINNEY, AD ;
JAMES, DR .
JOURNAL OF MAXILLOFACIAL SURGERY, 1985, 13 (03) :136-143
[3]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[4]   In-vitro assessment of a registration protocol for image guided implant dentistry [J].
Birkfellner, W ;
Solar, P ;
Gahleitner, A ;
Huber, K ;
Kainberger, F ;
Kettenbach, J ;
Homolka, P ;
Diemling, M ;
Watzek, G ;
Bergmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :69-78
[5]  
Bucholz R, 2000, Stud Health Technol Inform, V70, P39
[6]   Three-dimensional facial anthropometry using a laser surface scanner: Validation of the technique [J].
Bush, K ;
Antonyshyn, O .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (02) :226-235
[7]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[8]   Navigational precision of drilling tools preventing damage to the mandibular canal [J].
Gaggl, A ;
Schultes, G ;
Kärcher, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2001, 29 (05) :271-275
[9]   Computer assisted oral and maxillofacial surgery -: a review and an assessment of technology [J].
Hassfeld, S ;
Mühling, J .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 30 (01) :2-13
[10]   Comparative examination of the accuracy of a mechanical and an optical system in CT and MRT based instrument navigation [J].
Hassfeld, S ;
Mühling, J .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 29 (06) :400-407