Experimental exploration on airtightness performance of residential buildings in the hot summer and cold winter zone in China

被引:17
作者
Zheng, Hanjie [1 ]
Long, Enshen [1 ]
Cheng, Zhu [1 ]
Yang, Zhao [1 ]
Jia, Yonghong [1 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, MOE Key Lab Deep Earth Sci & Engn, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Residential building; Airtightness performance; Partial space heating; cooling; Window opening; Hot summer and cold winter zone; AIR-TIGHTNESS; ENERGY IMPACT; POWER-LAW; INFILTRATION; LEAKAGE; HOUSES; DWELLINGS; AREA; FLOW;
D O I
10.1016/j.buildenv.2022.108848
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The partial space heating/cooling mode and window opening for natural ventilation are significant character-istics of residential buildings' usage patterns in the Hot Summer and Cold Winter (HSCW) zone. At present, less attention has been paid to the partial space airtightness performance of residential buildings in this zone. In this study, the airtightness measurements of 4 spaces (whole space-Space 1, living room-Space 2, living room & bedroom-Space 3, living room & study-Space 4) in 11 newly-built and 3 existing high-rise apartments in Chengdu were carried out by the Blower Door Test method (BDT). Under the initial condition, the space with the best airtightness performance is Space 1, and the space with the worst airtightness performance is Space 2. The general disregard for the structural gaps of inner doors during the construction and installation is pointed as the most probable cause for such a significant difference in the airtightness performance under the initial condition of the 4 tested spaces. Although the implementation of stricter building design regulation is advantageous for upgrading whole-suite airtightness performance, the airtightness of the partial space has not been given enough attention, which is quite important in partial heating/cooling apartments. It may be necessary to emphasize the requirements for partial space airtightness in the building performance standards of HSCW zone.
引用
收藏
页数:14
相关论文
共 48 条
  • [1] Experimental analysis of air tightness in Mediterranean buildings using the fan pressurization method
    Alfano, F. R. d'Ambrosio
    Dell'Isola, M.
    Ficco, G.
    Tassini, F.
    [J]. BUILDING AND ENVIRONMENT, 2012, 53 : 16 - 25
  • [2] [Anonymous], 2017, GBT 34010 2017
  • [3] [Anonymous], 2019, DB5150272008
  • [4] [Anonymous], 2001, 138292001 EN
  • [5] [Anonymous], 2010, JGJ 134 2010
  • [6] AIR-FLOW THROUGH CRACKS
    BAKER, PH
    SHARPLES, S
    WARD, IC
    [J]. BUILDING AND ENVIRONMENT, 1987, 22 (04) : 293 - 304
  • [7] Factors influencing envelope airtightness of lightweight timber-frame houses built in the Czech Republic in the period of 2006?2019
    Bohm, Martin
    Berankova, Jitka
    Brich, Jiri
    Polasek, Marek
    Srba, Jaromir
    Nemcova, Dana
    Cerny, Robert
    [J]. BUILDING AND ENVIRONMENT, 2021, 194
  • [8] Building Energy Conservation Research Center of Tsinghua University, 2020, ANN REPORT CHINA BUI
  • [9] Measured air tightness performance of residential buildings in North China and its influence on district space heating energy use
    Chen, Shuqin
    Levine, Mark D.
    Li, Haiying
    Yowargana, P.
    Xie, Linna
    [J]. ENERGY AND BUILDINGS, 2012, 51 : 157 - 164
  • [10] Numerical and experimental validations of the theoretical basis for a nozzle based pulse technique for determining building airtightness
    Cooper, Edward
    Zheng, Xiaofeng
    Wood, Christopher J.
    [J]. BUILDING AND ENVIRONMENT, 2021, 188