Anatomical and Technical Predictors of Three-Dimensional Mitral Valve Area Reduction After Transcatheter Edge-To-Edge Repair

被引:15
作者
Kassar, Mohammad [1 ]
Praz, Fabien [1 ]
Hunziker, Lukas [1 ]
Pilgrim, Thomas [1 ]
Windecker, Stephan [1 ]
Seiler, Christian [1 ]
Brugger, Nicolas [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, CH-3010 Bern, Switzerland
关键词
Mitral valve area; Transcatheter edge-to-edge repair; MitraClip; Latrogenic mitral stenosis; Three-dimensional echocardiography; EUROPEAN ASSOCIATION; ECHOCARDIOGRAPHY; MANAGEMENT; SURGERY; SOCIETY; 2D;
D O I
10.1016/j.echo.2021.08.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Among current transcatheter therapies for the treatment of mitral regurgitation, the MitraClip (MC; Abbott Vascular, Abbott Park, IL) system is the most commonly used. MitraClip implantation is usually contraindicated in patients with a mitral valve area (MVA) < 4.0 cm(2). However, little is known about the real impact of MC implantation on MVA. Our goal was to investigate the factors influencing MVA reduction and derive the minimal MVA required to prevent the development of a clinically significant mitral stenosis (MVA < 1.5 cm(2)) in different clinical scenarios. Methods: Using three-dimensional data sets, the annulus and leaflet anatomy and MVA before clip implanta-tion (MVA(BC)) were assessed. After each MC implant (NTR or XTR), the relative MVA reduction and the absolute residual MVA were measured and their predictors evaluated. Results: The present analysis included 116 patients. An MC XTR was the first device implanted in 50% of the subjects, and 53% were treated with a single implant. The MVA reduction following one XTR was 57% +/- 7% versus 52% +/- 8% after one NTR (P = .001). A lower MVA reduction was observed when the MC was placed commissural/central versus paracentral (50% +/- 8% vs 57% +/- 7%, P < .0001). After a second device, the additional MVA reduction was higher when creating a triple-compared with a double-orifice morphology (34% +/- 11% vs 25% +/- 9%, P = .001). The MVA after one MC correlated with MVA(BC) as well as with the clip type and position (r = 0.91, P < .0001). The MVA(BC), orifice morphology, and first device position predicted MVA after two implants (r = 0.82, P < .0001). Based on the mathematical relationship between these param-eters, the minimal MVA(BC) needed in eight different clinical scenarios was summarized in a decision algorithm: the values ranged from 3.5 to 4.7 cm(2) for one and 4.5 to 6.3 cm(2) for two MC strategies. Conclusions: The minimal native MVA preventing clinically relevant MS after transcatheter edge-to-edge repair is predicted by the number and location of clip(s), orifice morphology, and device type. Based on these parameters, an algorithm has been derived to optimize patient selection and preprocedural planning.
引用
收藏
页码:96 / 104
页数:9
相关论文
共 17 条
[1]   Analysis of Procedural Effects of Percutaneous Edge-to-Edge Mitral Valve Repair by 2D and 3D Echocardiography [J].
Altiok, Ertunc ;
Hamada, Sandra ;
Brehmer, Kathrin ;
Kuhr, Kathrin ;
Reith, Sebastian ;
Becker, Michael ;
Schroeder, Joerg ;
Almalla, Mohammad ;
Lehmacher, Walter ;
Marx, Nikolaus ;
Hoffmann, Rainer .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (06) :748-755
[2]  
Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
[3]   Assessment of Mitral Valve Area During Percutaneous Mitral Valve Repair Using the MitraClip System Comparison of Different Echocardiographic Methods [J].
Biaggi, Patric ;
Felix, Christian ;
Gruner, Christiane ;
Herzog, Bernhard A. ;
Hohlfeld, Sabine ;
Gaemperli, Oliver ;
Staehli, Barbara E. ;
Paul, Michaela ;
Held, Leonhard ;
Tanner, Felix C. ;
Gruenenfelder, Juerg ;
Corti, Roberto ;
Bettex, Dominique .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (06) :1032-1040
[4]   Real-time 3D transoesophageal measurement of the mitral valve area in patients with mitral stenosis [J].
Dreyfus, Julien ;
Brochet, Eric ;
Lepage, Laurent ;
Attias, David ;
Cueff, Caroline ;
Detaint, Delphine ;
Himbert, Dominique ;
Iung, Bernard ;
Vahanian, Alec ;
Messika-Zeitoun, David .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (10) :750-755
[5]   Advanced Protocol for Three-Dimensional Transesophageal Echocardiography Guidance Implementing Real-Time Multiplanar Reconstruction for Transcatheter Mitral Valve Repair by Direct Annuloplasty [J].
Geyer, Martin ;
Sotiriou, Efthymios ;
Tamm, Alexander R. ;
Ruf, Tobias F. ;
Kreidel, Felix ;
Yang, Yang ;
Emrich, Tilman ;
Beiras-Fernandez, Andres ;
Gori, Tommaso ;
Muenzel, Thomas ;
Schulz, Eberhard ;
von Bardeleben, Ralph Stephan .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (10) :1359-1365
[6]   Vena contracta area for severity grading in functional and degenerativemitral regurgitation: a transoesophageal 3D colour Doppler analysis in 500 patients [J].
Goebel, Bjoern ;
Heck, Roland ;
Hamadanchi, Ali ;
Otto, Sylvia ;
Doenst, Torsten ;
Jung, Christian ;
Lauten, Alexander ;
Figulla, Hans R. ;
Schulze, P. Christian ;
Poerner, Tudor C. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (06) :639-646
[7]   Effect of percutaneous mitral repair with the MitraClip® device on mitral valve area and gradient [J].
Herrmann, Howard C. ;
Kar, Saibal ;
Siegel, Robert ;
Fail, Peter ;
Loghin, Catalin ;
Lim, Scott ;
Hahn, Rebecca ;
Rogers, Jason H. ;
Bommer, William J. ;
Wang, Andrew ;
Berke, Andrew ;
Lerakis, Stamatios ;
Kramer, Paul ;
Wong, S. Chiu ;
Foster, Elyse ;
Glower, Don ;
Feldman, Ted .
EUROINTERVENTION, 2009, 4 (04) :437-442
[8]   Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging [J].
Lang, Roberto M. ;
Badano, Luigi P. ;
Mor-Avi, Victor ;
Afilalo, Jonathan ;
Armstrong, Anderson ;
Ernande, Laura ;
Flachskampf, Frank A. ;
Foster, Elyse ;
Goldstein, Steven A. ;
Kuznetsova, Tatiana ;
Lancellotti, Patrizio ;
Muraru, Denisa ;
Picard, Michael H. ;
Rietzschel, Ernst R. ;
Rudski, Lawrence ;
Spencer, Kirk T. ;
Tsang, Wendy ;
Voigt, Jens-Uwe .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (01) :1-U170
[9]   Comprehensive Assessment of Mitral Valve Geometry and Cardiac Remodeling With 3-Dimensional Echocardiography After Percutaneous Mitral Valve Repair [J].
Mantegazza, Valentina ;
Pasquini, Annalisa ;
Agati, Luciano ;
Fusini, Laura ;
Muratori, Manuela ;
Gripari, Paola ;
Ali, Sarah Ghulam ;
Vignati, Carlo ;
Bartorelli, Antonio Luca ;
Ferrari, Cristina ;
Alamanni, Francesco ;
Pepi, Mauro ;
Tamborini, Gloria .
AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (07) :1195-1203
[10]   The EVEREST II Trial: Design and rationale for a randomized study of the evalve mitraclip system compared with mitral valve surgery for mitral regurgitation [J].
Mauri, Laura ;
Garg, Pallav ;
Massaro, Joseph M. ;
Foster, Elyse ;
Glower, Donald ;
Mehoudar, Paul ;
Powell, Ferolyn ;
Komtebedde, Jan ;
McDermott, Elizabeth ;
Feldman, Ted .
AMERICAN HEART JOURNAL, 2010, 160 (01) :23-29