Understanding the Popcorn Effect During Holmium Laser Lithotripsy for Dusting

被引:47
作者
Aldoukhi, Ali H.
Roberts, William W.
Hall, Timothy L.
Teichman, Joel M. H.
Ghani, Khurshid R.
机构
[1] Univ Michigan, Div Endourol, Dept Urol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ British Columbia, Dept Urol Sci, Vancouver, BC, Canada
关键词
YAG LITHOTRIPSY; PULSE DURATION; FLEXIBLE URETEROSCOPY; STONE FRAGMENTATION; EFFICIENCY VARIES; RETROPULSION; SETTINGS;
D O I
10.1016/j.urology.2018.08.031
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To assess low and high power settings for the popcorn technique, and relationship of laser fiber-to-stone distance and calyceal size on submillimeter fragmentation. Our in vitro findings may help guide strategies to improve a dusting technique for ureteroscopy. METHODS BegoStones were fragmented in small (127 mm(3)) and large (411 mm(3)) sized bulbs to simulate calyces, using a 120 W Ho:YAG laser. A 242 mu m fiber was introduced through a ureteroscope mounted to a 3D positioner with its tip located at 0 or 2 mm distance from the stones. 20 W [1 J x 20 Hz, 0.5 J x 40 Hz] and 40 W [1 J x 40 Hz, 0.5 J x 80 Hz] settings were assessed, including short pulse and long pulse modes. Total energy delivered was constant at 7.2 kJ. Primary outcome was percentage of stone mass converted to fragments <1 mm. High-speed imaging was performed to study stone movement and/or fragmentation. RESULTS For all settings, popcorn lithotripsy yielded more submillimeter fragments when performed with the fiber positioned on the stone compared to 2 mm from the stone (P <.05). Distribution of submillimeter fragments was higher when utilizing high frequencies regardless of pulse energy. At 2 mm distance, popcorning was more effective in the small model (P <.05). At 2 mm distance, short pulse was superior to long pulse. Video analysis showed fragmentation did not occur when stones collided with each other. At 80 Hz/2 mm distance, only 17.5% of pulses impacted fragments. CONCLUSION Popcorn technique is more effective when the fiber is directly in contact with stone, and when performed in a small calyceal model. Utilizing settings with higher frequencies may improve dusting outcomes. (C) 2018 Elsevier Inc.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 24 条
[21]   Holmium:Yag lithotripsy efficiency varies with energy density [J].
Vassar, GJ ;
Teichman, JMH ;
Glickman, RD .
JOURNAL OF UROLOGY, 1998, 160 (02) :471-476
[22]   Holmium:YAG lithotripsy:: Photothermal mechanism [J].
Vassar, GJ ;
Chan, KF ;
Teichman, JMH ;
Glickman, RD ;
Weintraub, ST ;
Pfefer, TJ ;
Welch, AJ .
JOURNAL OF ENDOUROLOGY, 1999, 13 (03) :181-190
[23]   Effect of Laser Settings and Irrigation Rates on Ureteral Temperature During Holmium Laser Lithotripsy, an In Vitro Model [J].
Wollin, Daniel A. ;
Carlos, Evan C. ;
Tom, Westin R. ;
Simmons, W. Neal ;
Preminger, Glenn M. ;
Lipkin, Michael E. .
JOURNAL OF ENDOUROLOGY, 2018, 32 (01) :59-63
[24]   Variable Pulse Duration From a New Holmium: YAG Laser: The Effect on Stone Comminution, Fiber Tip Degradation, and Retropulsion in a Dusting Model [J].
Wollin, Daniel A. ;
Ackerman, Anika ;
Yang, Chen ;
Chen, Tony ;
Simmons, Walter Neal ;
Preminger, Glenn M. ;
Lipkin, Michael E. .
UROLOGY, 2017, 103 :47-51