Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI

被引:27
|
作者
Minamimoto, Ryogo [1 ,2 ]
Levin, Craig [2 ]
Jamali, Mehran [1 ,2 ]
Holley, Dawn [3 ]
Barkhodari, Amir [1 ]
Zaharchuk, Greg [3 ]
Iagaru, Andrei [1 ]
机构
[1] Stanford Univ, Div Nucl Med & Mol Imaging, Dept Radiol, 300 Pasteur Dr,H2200, Stanford, CA 94305 USA
[2] Stanford Univ, Mol Imaging Program Stanford, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
PET/MRI; PET/CT; Time of flight; Artifact; Image quality; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; ATTENUATION CORRECTION; RESPIRATORY MOTION; CLINICAL-EXPERIENCE; DENTAL IMPLANTS; ARTIFACTS; ATLAS; MRI; REGISTRATION; GENERATION;
D O I
10.1007/s11307-016-0939-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) scanner with time of flight (TOF) technology is now available for clinical use. The aim of this study is to evaluate the potential of TOF PET in PET/MRI to reduce artifacts in PET images when compared to non-TOF PET/MRI, TOF PET/X-ray computed tomography (CT), and non-TOF PET/CT. All patients underwent a single 2-deoxy-2-[F-18]fluoro-d-glucose ([F-18]FDG) injection, followed first by PET/CT, and subsequently by PET/MRI. PET/CT exams were requested as standard-of-care for oncological indications. Using the PET acquisitions datasets, 4 series of images (TOF PET/CT, non-TOF PET/CT, TOF PET/MRI, and non-TOF PET/MRI) were reconstructed. These image series were visually evaluated for: (1) dental metal artifacts, (2) breathing artifacts, and (3) pelvic artifacts due to scatter correction errors from high bladder [F-18]FDG concentration. PET image quality was assessed by a 3-point scale (1-clinically significant artifact, 2-non clinically significant artifact, and 3-no artifact). Twenty-five patients (mean +/- SD age: 56 +/- 13 years old; female: 10, male: 15) were enrolled. TOF PET/MRI, non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT scores 2.8, 2.5, 2.4, and 2.3, respectively for the presence of dental artifacts, 2.8, 2.5, 2.2, and 1.9, respectively, for the presence of breathing artifacts, and 2.7, 1.7, 2.0, and 1.3, respectively, for the presence of pelvic artifacts TOF PET/MRI images showed the highest image quality scores among the 4 datasets of PET images. The superior timing resolution and resulting TOF capability of the new PET/MRI scanner improved PET image quality in this cohort by reducing artifacts compared to non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT.
引用
收藏
页码:776 / 781
页数:6
相关论文
共 50 条
  • [41] Evaluation of the PET component of simultaneous [18F]choline PET/MRI in prostate cancer: comparison with [18F]choline PET/CT
    Wetter, Axel
    Lipponer, Christine
    Nensa, Felix
    Heusch, Philipp
    Ruebben, Herbert
    Altenbernd, Jens-Christian
    Schlosser, Thomas
    Bockisch, Andreas
    Poeppel, Thorsten
    Lauenstein, Thomas
    Nagarajah, James
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (01) : 79 - 88
  • [42] MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
    Chun, Se Young
    Reese, Timothy G.
    Ouyang, Jinsong
    Guerin, Bastien
    Catana, Ciprian
    Zhu, Xuping
    Alpert, Nathaniel M.
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1284 - 1291
  • [43] Investigating Low-Dose Image Quality in Whole-Body Pediatric 18F-FDG Scans Using Time-of-Flight PET/MRI
    Schmall, Jeffrey P.
    Surti, Suleman
    Otero, Hansel J.
    Servaes, Sabah
    Karp, Joel S.
    States, Lisa J.
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (01) : 123 - 130
  • [44] Joint motion estimation and penalized image reconstruction algorithm with anatomical priors for gated TOF-PET/CT
    Tsai, Yu-Jung
    Liu, Chi
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02)
  • [45] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [46] Simultaneous reconstruction of attenuation and activity in ToF PET/MRI with additional transmission data
    Ester D’Hoe
    Pieter Mollet
    Ekaterina Mikhaylova
    Michel Defrise
    Stefaan Vandenberghe
    EJNMMI Physics, 2 (Suppl 1)
  • [47] Performance evaluation of a PET insert for preclinical MRI in stand-alone PET and simultaneous PET-MRI modes
    Emvalomenos, Gaelle
    Trajanovska, Sofie
    Pham, Binh T. T.
    Doughty, Peter
    Burnet, Jerome
    Smith, Isabelle
    Garipov, Ruslan
    Gregoire, Marie-Claude
    Sunn, Nana
    McGrath, John
    Meikle, Steven R.
    EJNMMI PHYSICS, 2021, 8 (01)
  • [48] Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Rezaei, Ahmadreza
    Defrise, Michel
    Bal, Girish
    Michel, Christian
    Conti, Maurizio
    Watson, Charles
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (12) : 2224 - 2233
  • [49] Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience
    Edwin E. G. W. ter Voert
    Patrick Veit-Haibach
    Sangtae Ahn
    Florian Wiesinger
    M. Mehdi Khalighi
    Craig S. Levin
    Andrei H. Iagaru
    Greg Zaharchuk
    Martin Huellner
    Gaspar Delso
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 1223 - 1233
  • [50] Fisher Information-Based Evaluation of Image Quality for Time-of-Flight PET
    Vunckx, Kathleen
    Zhou, Lin
    Matej, Samuel
    Defrise, Michel
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) : 311 - 321