A master-slave (M-S) based free environment (in-air) on-line trajectory control of a redundant surgical robot is presented in this work which can provide solution to precise positioning of the surgical robot tip that can be deployed for the internal organ inspection, radiosurgery of the gastrointestinal tumor, improvement in the precise placement of radiation source during brachytherapy, etc. This work deals with the online in-air 3D trajectory tracking control of a cable-driven 5-degrees of freedom (DOF) redundant slave robot deployed in the M-S based robotic surgical system presented towards robotic natural orifice transluminal endoscopic surgery (NOTES) purpose. A novel intelligent control technique involving an uncomplicated supervised radial basis function network (RBFN) based mapping is proposed to learn the inverse kinematics (IK) relationship of the redundant slave robot for tracking the desired 3D trajectory, which is given by the master robot under in-air environmental conditions. The proposed method eliminates the reckoning of Jacobian pseudo-inverse of the slave robot in real-time. To resolve the redundancy of the 5-DOF slave robot, a generalised approach in the weight update law during the learning phase of the inverse kinematic control is proposed. The proposed control algorithm's trajectory tracking performance is compared with the back propagation network (BPN) based approach and the gold standard closed-loop inverse kinematic (CLIK) redundant control algorithm involving instantaneous maximization of manipulability measure through both simulation and experimental studies. Root mean square error (RMSE) of 0.572 mm (simulation) and 0.600 mm (experiment) are obtained for the RBFN based approach as compared to that of the BPN (simulation: 0.910 mm and experiment: 1.500 mm) and CLIK (simulation: 0.607 mm and experiment: 0.900 mm) algorithms are reflecting its best performance towards trajectory tracking tasks. Thus, the novelty of the current study lies on the development of a simple, uncomplicated intelligent neural network controller overperforming in 3D trajectory tracking tasks by the standard kinematic control techniques such as CLIK and other model based techniques. The experimental setup for M-S based surgical system for robotic-NOTES is developed to validate the intelligent control technique.
引用
收藏
页数:20
相关论文
共 53 条
  • [1] [Anonymous], 2022, TOUCH 3D SYST
  • [2] Behera L., 2009, INTELLIGENT SYSTEMS
  • [3] Inverse Kinematics Control Methods for Redundant Snakelike Robot Teleoperation During Minimally Invasive Surgery
    Berthet-Rayne, Pierre
    Leibrandt, Konrad
    Gras, Gauthier
    Fraisse, Philippe
    Crosnier, Andre
    Yang, Guang-Zhong
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2018, 3 (03): : 2501 - 2508
  • [4] REALITI: A Robotic Endoscope Automated via Laryngeal Imaging for Tracheal Intubation
    Boehler, Quentin
    Gage, David S.
    Hofmann, Phyllis
    Gehring, Alexandra
    Chautems, Christophe
    Spahn, Donat R.
    Biro, Peter
    Nelson, Bradley J.
    [J]. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2020, 2 (02): : 157 - 164
  • [5] Chavez AG, 2019, IEEE INT C INT ROBOT, P7211, DOI [10.1109/IROS40897.2019.8967888, 10.1109/iros40897.2019.8967888]
  • [6] RBF-Neural-Network-Based Adaptive Robust Control for Nonlinear Bilateral Teleoperation Manipulators With Uncertainty and Time Delay
    Chen, Zheng
    Huang, Fanghao
    Sun, Weichao
    Gu, Jason
    Yao, Bin
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2020, 25 (02) : 906 - 918
  • [7] State of the art in robots used in minimally invasive surgeries. Natural Orifice Transluminal Surgery (NOTES) as a particular case
    Eduardo Diaz, Carlos
    Fernandez, Roemi
    Armada, Manuel
    Garcia Gutierrez, Felipe de Jesus
    [J]. INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2015, 42 (06): : 508 - 532
  • [8] In vitro evaluation of forces exerted by a new computer-assisted colonoscope (the NeoGuide Endoscopy System)
    Eickhoff, A.
    Jakobs, R.
    Kamal, A.
    Mermash, S.
    Riemann, J. F.
    van Dam, J.
    [J]. ENDOSCOPY, 2006, 38 (12) : 1224 - 1229
  • [9] DESIGN AND DEVELOPMENT OF IN VIVO ROBOT FOR BIOPSY
    Garg, A.
    Vikram, C. S.
    Gupta, S.
    Sutar, M. K.
    Pathak, P. M.
    Mehta, N. K.
    Sharma, A. K.
    Gupta, V. K.
    [J]. MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2014, 42 (03) : 278 - 295
  • [10] Transvaginal laparoscopic nephrectomy: Development and feasibility in the porcine model
    Gettman, MT
    Lotan, Y
    Napper, CA
    Cadeddu, JA
    [J]. UROLOGY, 2002, 59 (03) : 446 - 450