Systematic Review of the Diagnostic Accuracy of Haptoglobin, Serum Amyloid A, and Fibrinogen versus Clinical Reference Standards for the Diagnosis of Bovine Respiratory Disease

被引:32
作者
Abdallah, A. [1 ,2 ]
Hewson, J. [3 ]
Francoz, D. [1 ]
Selim, H. [2 ]
Buczinski, S. [1 ]
机构
[1] Univ Montreal, Dept Sci Clin, Fac Med Vet, St Hyacinthe, PQ, Canada
[2] Zagazig Univ, Fac Vet Med, Zagazig, Egypt
[3] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
关键词
Bias; Gold standard; Quality assessment; Sensitivity; Specificity; ACUTE-PHASE PROTEINS; TRACT DISEASE; DAIRY CALVES; LUNG LESIONS; A SAA; HEALTH; CATTLE; BIAS; SENSITIVITY; PERFORMANCE;
D O I
10.1111/jvim.13975
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundBovine respiratory disease (BRD) is a worldwide animal health concern especially in feedlot, dairy, and veal calves. One of the greatest challenges is the absence of a gold standard for achieving an accurate antemortem diagnosis. Various blood markers, including the acute-phase proteins (AAP), have been proposed as potential valuable tools for BRD diagnosis. ObjectivesTo perform a systematic review of the literature to assess the accuracy of selected APP (haptoglobin [Hp], serum amyloid A [SAA], and fibrinogen [Fb]) as diagnostic tools for cattle with naturally occurring BRD when compared with clinical reference standards of diagnosis. MethodsThis review was performed with eligible studies selected from CAB Abstract and MEDLINE from 1946 to 2015, as well as the gray literature. Methodological quality of included studies was assessed using the QUADAS-2 tool developed for diagnostic accuracy studies. The accuracy parameters sensitivity (Se) and specificity (Sp) were obtained from the articles or through contact with the authors when not directly reported. ResultsA total of 314 studies were identified, from them, 23 met inclusion criteria as diagnostic studies for naturally occurring BRD. Quality of studies showed high risk of bias for case selection (70% of articles) and unclear risk of bias for index test (65%), reference standard (74%), and flow and timing (61%). There were high concerns regarding applicability for case selection (61% of studies) and reference standards used for defining BRD (48%). The concerns regarding index test application were low (83% of the studies). Only 4-8 studies could be included in the meta-analysis for each APP. No pooled estimates or pooled accuracy measurements were performed due to the low number of studies and multiple differences between studies, including reference standard definitions. Conclusions and Clinical ImportanceOn the basis of these findings, it is not possible to make conclusions regarding the accuracy of APP for BRD diagnosis. The reporting of accuracy of APP for BRD detection is inconsistent among studies. Recommendations to improve capability for future meta-analyses in this area include reporting studies on diagnostic tests following the Standard for the Reporting of Diagnostic Accuracy Studies (STARD), as well as trying to standardize BRD definition across future studies.
引用
收藏
页码:1356 / 1368
页数:13
相关论文
共 69 条
  • [1] Al-Qudah KM, 2009, REV MED VET-TOULOUSE, V160, P231
  • [2] Second trimester serum tests for Down's Syndrome screening
    Alldred, S. K.
    Deeks, J. J.
    Guo, B.
    Neilson, J. P.
    Alfirevic, Z.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (06):
  • [3] CONCENTRATIONS OF SERUM AMYLOID-A (SAA) AND HAPTOGLOBIN (HP) AS PARAMETERS OF INFLAMMATORY DISEASES IN CATTLE
    ALSEMGEEST, SPM
    KALSBEEK, HC
    WENSING, T
    KOEMAN, JP
    VANEDEREN, AM
    GRUYS, E
    [J]. VETERINARY QUARTERLY, 1994, 16 (01) : 21 - 23
  • [4] Respiratory disease in calves: Microbiological investigations on trans-tracheally aspirated bronchoalveolar fluid and acute phase protein response
    Angen, Oystein
    Thomsen, John
    Larsen, Lars Erik
    Larsen, Jesper
    Kokotovic, Branko
    Heegaard, Peter M. H.
    Enemark, Jorg M. D.
    [J]. VETERINARY MICROBIOLOGY, 2009, 137 (1-2) : 165 - 171
  • [5] [Anonymous], 2011, Dietary Guidelines for Americans, P1
  • [6] [Anonymous], TECHNICAL B REG MED
  • [7] [Anonymous], VET HAEMATOLOGY
  • [8] [Anonymous], 2013, CMAJ
  • [9] Arslan HH, 2010, REV MED VET-TOULOUSE, V161, P535
  • [10] Bauer J. D., 1974, CLIN LAB METHODS